It shall only be possible to reinitiate the output signal afterboth inputs have been releasedThe output signal may only appear when both inputs areactivated within 0.5 seconds of each other. If the inputs arenot actuated synchronously, the output will be preventeduntil the inputs are re-applied within this time scale. This iscalled synchronous actuation.In the case of failure, the parts of the two-hand control device shallbehave in accordance with EN 954-1.5.4.1 Typical connectionInputsPLCOutput supplyInput supplyOutputs47143<strong>Machinery</strong> <strong>Protection</strong><strong>Devices</strong>Y1Y2P2HZ X1EnablemachinemovementFig. 48: Typical two-hand circuit with Pilz P2HZ X1NB. Please refer to Pilz Safety Catalogue (1) for relay details.