10.07.2015 Views

Miltronics 10075-DA400 User Manual Rev 2.7.pdf - Pacer Instruments

Miltronics 10075-DA400 User Manual Rev 2.7.pdf - Pacer Instruments

Miltronics 10075-DA400 User Manual Rev 2.7.pdf - Pacer Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

By <strong>Miltronics</strong> Mfg., Inc. Phone: (603) 352-018795 Krif Road Fax: (603) 352-1036Keene, NH 03431 USA sales@pacer-instruments-usa.comPress the SAMPLE RATE key to change the measurement averagingrate (“sample rate”) of the unit: An average value of airspeed measurements during thepreceding 2 seconds is displayed. An average value of airspeed measurements during thepreceding 4 seconds is displayed. An average value of airspeed measurements during thepreceding 8 seconds is displayed. An average value of airspeed measurements during thepreceding 16 seconds is displayed.By <strong>Miltronics</strong> Mfg., Inc. Phone: (603) 352-018795 Krif Road Fax: (603) 352-1036Keene, NH 03431 USA sales@pacer-instruments-usa.comAPPENDIX G – VIEWING AND CAPTURING DATA(IF EQUIPPED WITH EITHER USB OR RS232 OUTPUTS)There are many ways to capture the serial port data from the <strong>Pacer</strong>Instrument. The simplest method is to use a terminal emulator program.Using a terminal emulator allows the serial COM port to be opened, withthe above port settings, and real-time data to be viewed from theinstrument. One such terminal emulator program is WindowsHyperTerminal.To launch Windows HyperTerminal, go to:START → All Programs → Accessories → Communications →HyperTerminalEnter a name for the Connection, such as “<strong>Pacer</strong> <strong>DA400</strong>” and choose anicon.Press the MAX/MIN key to record and display the maximum airspeedreading. The maximum airspeed reading display will alternate with theletter “H” displayed with the sample rate. Press the MAX/MIN keyagain to record an d hold the minimum airspeed reading. The minimum airspeedreading display will alternate with the letter “L” displayed with the sample rate.For example: alternating with signifies that 1065 is the highest airspeedreading since the MAX/MIN key was pressed, and the sample rate is set to 8seconds. alternating with signifies that 82 is the lowest airspeedreading since the MAX/MIN key was pressed, and the sample rate is set to 16seconds.To exit MAX/MIN mode, press the SAMPLE RATE key.Click OK.<strong>DA400</strong> <strong>User</strong> <strong>Manual</strong>, PN <strong>10075</strong> <strong>Miltronics</strong> Mfg. Svcs., Inc.<strong>Rev</strong> 2.7, 04-Sept-2013 www.pacer-instruments-usa.comCopyright © 2013, <strong>Miltronics</strong> Mfg. Svcs., Inc. Page 8 of 24<strong>DA400</strong> <strong>User</strong> <strong>Manual</strong>, PN <strong>10075</strong> <strong>Miltronics</strong> Mfg. Svcs., Inc.<strong>Rev</strong> 2.7, 04-Sept-2013 www.pacer-instruments-usa.comCopyright © 2013, <strong>Miltronics</strong> Mfg. Svcs., Inc. Page 17 of 24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!