Figure 7. System wiring diagram for 4-wire duct smoke detectors:CAUTIONDo not loop wire under terminals when wiring detectors. Break wire runs to provide system supervision of connections.POWER INPUTS ACCEPT24 VDC, 24 VAC 50-60 HZ,CONNECT POWER SOURCETO APPROPRIATE TERMINALSOF EACH DETECTOR.AVAILABLE POWER INPUTS9 1024VAVAILABLE POWER INPUTS9 1024VCONNECT POWER SOURCETO APPROPRIATE TERMINALSOF EACH DETECTOR. SEESPECIFICATIONS FORADDITIONAL POWER SUPPLYINFORMATION.AUX. CONTACT RATINGS10A @ 30 VDC RESISTIVE100mA MINIMUM @ 5 VDCNOT INTENDED FORCONNECTION TO CONTROLPANELS.N.C.ALARM AUXILIARY CONTACTSFOR FAN SHUTDOWN, ETC.16 6 17 7 18 8C.N.O.N.O.C.N.C.N.C.ALARM AUXILIARY CONTACTSFOR FAN SHUTDOWN, ETC.16 6 17 7 18 8C.N.O.N.O.C.N.C.FOR WIRING OF AUXILIARYDEVICES, REFER TOMANUFACTURER’SINSTALLATION INSTRUCTIONSOR CONTACT MANUFACTURER.TROUBLE CONTACT RATING2.0 A @ 30 VDC resistiveALARM AUXILIARY CONTACTS SHOWN INSTANDBY. CONTACTS TRANSFER DURINGALARM AS INDICATED BY THE ARROWS.SUPERVISORY TROUBLE CONTACTSALARM AUXILIARY CONTACTS SHOWN INSTANDBY. CONTACTS TRANSFER DURINGALARM AS INDICATED BY THE ARROWS.SUPERVISORY TROUBLE CONTACTS14 3 143NOTE: THE SUPERVISORY RELAY NOWPROVIDES A "FORM C" CONTACT FORCUSTOMIZED APPLICATIONS.FOR STANDARD APPLICATIONS, ONLYTHE "NO" CONTACT IS USEDTROUBLE CONTACTS CLOSED IN ALARM AND STANDBY.CONTACTS OPEN WHILE DETECTOR PCB OR POWER ISREMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPENCONTACTS SIGNAL TROUBLE CONDITION TO PANEL.TROUBLE CONTACTS CLOSED IN ALARM AND STANDBY.CONTACTS OPEN WHILE DETECTOR PCB OR POWER ISREMOVED OR WHEN TAMPER FEATURE TIMES OUT. OPENCONTACTS SIGNAL TROUBLE CONDITION TO PANEL.+55ALARMINITIATIONLOOPALARMINITIATIONCONTACTS4CONTACTS SHOWNOPEN IN STANDBY.CONTACTS CLOSEIN ALARM.ALARMINITIATIONCONTACTS4CONTACTS SHOWNOPEN IN STANDBY.CONTACTS CLOSEIN ALARM.UL LISTED 4-WIRECONTROL PANELFIRST DETECTOR IN THE LOOP<strong>DH100ACDCLP</strong>LAST DETECTOR IN THE LOOP<strong>DH100ACDCLP</strong>EOL RESISTORSPECIFIED BYPANEL MANUFACTURERA78-2352-11Figure 8. Wiring diagram for <strong>DH100ACDCLP</strong>to APA451: 4-Wire Wiring to APA451Figure 9. Wiring diagram for <strong>DH100ACDCLP</strong> toRTS451KEY and interconnect feature:DH100ACDCAlarm SignalAux. Power +Sup. N. O.1519142APA451Alarm(Red LED)<strong>DH100ACDCLP</strong>Alarm SignalAux. Power +Sup. N. O.1519141RTS451/RTS451KEY*(Red LED) AlarmFor RTS451KEYonly <strong>with</strong>out acontrol panel.*Sup. COMAux. Power —320 13Power(Green LED)CommonSup. COMAux. Power —32062(Green LED)PowerReset23NOTE:Wiring diagram shown is for DH100ACDCLWP 4-wire ductsmoke detector system equipped <strong>with</strong>out a control panel.Test1145Figure 10. Multiple fan shutdown (interconnect):1 612 16FANCONTROLA B CDETECTOR 1SYSTEMCONTROLPOWER ORTHERMOSTAT1 612 16FANCONTROLA B CDETECTOR 2SYSTEMCONTROLPOWER ORTHERMOSTAT1 612 16FANCONTROLA B CDETECTOR 3SYSTEMCONTROLPOWER ORTHERMOSTAT1—NEXTDETECTOR+12Important Interconnect Notes• When using the interconnect feature, all interconnectedunits must be powered <strong>with</strong>the same, independent supply.• Polarity must be maintained throughout theinterconnect wiring. Connect terminal 12 onunit 1 to terminal 12 on unit 2 and so on.Similarly, connect terminal 1 on unit 1 to terminal1 on unit 2 and so on.D200-14-00 6 I56-0084-00

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!