PRODUCT SPECIFICATIONS<strong>AEPT</strong> DipswitchesThe <strong>AEPT</strong> air handler blower motors have been pre-programmed for operation at four distinct air flow levelswhen operating in the Cooling, Heat Pump Heating, Backup Heating (Electric Heating) and Backup + HeatPump Heating. Each mode has four levels to deliver different CFM. Simply flip the dipswitch, and you canget a different CFM combination.Setting Up Your MotorDipswitchFunctionInstructionsNumber1 Electric Heat ModeSelect the taps allowed in the tables (Dipswitch 1/2) below.2 Electric Heat Mode3 N/A N/AON = The system operates with single-stage units using a single-stagecooling or heat pump thermostat. (factory default)OFF = The system operates with two-stage units with either aconventional two-stage cooling/heat pump thermostat or with an4 Thermostat Modeencoded two-stage thermostat for cooling operation. The encodedthermostats can be used with two-stage condensing units in retrofitapplications where there aren’t enough existing wires available forconnections to the indoor thermostat and outdoor units.5 Cooling/Heat Pump Mode Find the air flow for your application in the tables (Dipswitch 5/6) below.6 Cooling/Heat Pump Mode Set up the motor based on the outdoor unit capacity tons.7 Trim CFM Adjust Mode Increase or decrease your selected air flow to fit your requirement.ON-OFF = Increases selected Cool/Heat Pump air flow by 10%.8 Trim CFM Adjust Mode OFF-ON = Decreases selected Cool/Heat Pump air flow by 15%NOTE: Other settings have no effect on the set air flow.Dipswitch 1/2<strong>AEPT</strong>30HeatingElement (kW)SwitchPositionEmergencyBackupUp to 10 OFF-OFF 1,100 1,210Up to 10 ON-OFF 850 9355 OFF-ON 700 770<strong>AEPT</strong>36/60Heat Pumpwith BackupHeatingElement (kW)SwitchPositionEmergencyBackupHeat Pumpwith BackupUp to 20 OFF-OFF 2,050 2,150Up to 20 ON-OFF 1,750 1,835Up to 15 OFF-ON 1,600 1,680Up to 10 ON-ON 1,200 1,260Dipswitch 5/6<strong>AEPT</strong>30Outdoor Unit Switch Indoor <strong>Air</strong> Flow(Tons) Position Cool Heat Pump2.5 OFF-OFF 1,100 1,1002 ON-OFF 800 8001.5 OFF-ON 600 600<strong>AEPT</strong>36/60Outdoor Unit Switch Indoor <strong>Air</strong> Flow(Tons) Position Cool Heat Pump5 OFF-OFF 1,800 1,8004 ON-OFF 1,580 1,5803.5 OFF-ON 1,480 1,4803 ON-ON 1,200 1,200NOTE: When applying a humidistat (normally closed), refer to the installation and operating instructions. Thehumidistat can adjust the cooling air flow to 85%.6
PRODUCT SPECIFICATIONSHeat Kit SelectionModel <strong>AEPT</strong>030-00C-1/00C-1A <strong>AEPT</strong>036-00C-1/00C-1A <strong>AEPT</strong>060-00C-1/00C-1AHKR-05CXHKR-08C X XHKR-10C X X XHKR-15C X XHKR-20CXHKR-21CXNOTE: The C indicates circuit breakers are optional*Heat Kit requires 3-phase power supply7