10.07.2015 Views

SIMATIC Panel PC - Automatyka Siemens

SIMATIC Panel PC - Automatyka Siemens

SIMATIC Panel PC - Automatyka Siemens

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

OptionsFor individually expandable system availabilityThe availability of a plant is decisive for its productivity. Therugged design and high industrial capability mean that the<strong>SIMATIC</strong> industrial <strong>PC</strong>s have a high fault tolerance. A matchedrange of hardware and software options is available for applicationswith special system availability demands. <strong>PC</strong> solutionscan then be optimized simply and reliably, and matched to theindividual availability requirements.Uninterruptible power supply (UPS)The power supply for high industrial requirements fitted to<strong>SIMATIC</strong> <strong>PC</strong>s covers voltage dips up to 20 ms (Namur requirement).The uninterruptible SITOP and Masterguard power suppliesin 24 V DC or 115/230 V AC, or customized UPSs, areavailable for nonstop applications in the event of power failures.RAID1 configuration (mirror disks)A further improvement can be achieved using a RAID1 configuration.In this case, all data is saved in parallel on two harddisks by automatic mirroring.If one of the two drives fails, all user data is still neverthelessretained. The redundant architecture provides the followingbenefits:■■■Reliable avoidance of data losses in case of failures, sinceit is highly improbable that the two disks will fail simultaneously.If one hard disk fails, the system remains operational.Automatic data security without the user having to intervene.<strong>SIMATIC</strong> <strong>PC</strong> DiagMonitorThe <strong>PC</strong> diagnostics/alarming software <strong>SIMATIC</strong> <strong>PC</strong> DiagMonitordetects possible hardware and software faults at an earlystage. Diagnostics alarms are automatically forwarded to theuser via LAN, e-mail or text message, or forwarded by the O<strong>PC</strong>to directly supply the alarm to the software application (e.g.WinCC flexible, WinCC, WinAC or other O<strong>PC</strong>-compatible software).The integrated time synchronization function permitsoperation of the industrial <strong>PC</strong>s without CMOS battery.This further reduces the maintenance costs.The <strong>SIMATIC</strong> <strong>PC</strong> DiagMonitor monitors, reports and visualizesthe operating states of <strong>SIMATIC</strong> <strong>PC</strong>s both locally and remote.DiagMonitor alarms the user, executes programs automaticallyand records all results. Faults are thus detected at anearly stage and potential system failures efficiently avoided.Monitoring Reporting Visualizing Alarming Responding andrecording•<strong>PC</strong> hardware functions•Internal device temperature•Fan•Disk status•System states•Operating hours countermeter•Violation of permissibleoperating temperature•Fan failure/fault•Hard disk problems•Program interruption incase of watchdog timeout•Maintenance intervals(user-selectable)•Diagnostic LEDs oneach device•Locally on the monitorof the device•Via LAN on the centralserver•Graphic measured datadisplay•LAN•Text message on mobilephone•E-Mail to relevantperson•O<strong>PC</strong> and/or SNMP touser software•Activates reset (watchdog)•Executes programsautomatically(batch/executable files)•Records events (log file)Functions of the <strong>SIMATIC</strong> <strong>PC</strong> DiagMonitor6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!