B101Refrigerator Indicates NoFlame EstablishedIf the Flame Indicator is not illuminated,yet the Ignitor switch isON with 12 volts available to unitand flame at burner, then checkthe following:1. Keep in mind that the FlameIndicator will not illuminateunless a flame has been established.2. Set VOM to + 5 Volts scale.You should read from 1.5 to 2Volts DC at the terminals of theRelighter shown in Figure 3.23.If not, replace the Relighter.3. With the Ignitor Switch on, anda flame established, check firstthat the wires to the flame indicatorbulb are not reversed.Properly wired would be: redlead from bulb to brown harnesswire; black lead frombulb to white harness wireshown in Figure 3.24.4. With test probes at points indicatedin Figure 3.23, youshould read on the 5 Volt DCscale something less than 2Volts. If voltage is present andthe Flame Indicator still doesnot illuminate, then replaceFlame Indicator.Figure 3.23 Flame Indicator Check at White and Brown Term.Figure 3.24Flame Indicator Check3-12