B101a 2-Way, skip to Step 13.11. Check for 12 Volts at Points 1and 2 of switch and ground asshown in Figure 3.44 (AC-ELEC STDBY-DC switch isnow set at DC.12. There should be 12 Volts atboth Points 1 and 2. If not, andconnections are checked asproper, replace AC-ELECSTDBY-DC switch.13. Check for 12 volts at the DCheater terminals as shown inFigure 3.48.14. If there is no 12 volt reading, abad connection is indicatedbetween the thermostat andheater terminals.15. If 12 volts is present, check theDC heater for continuity asshown in Figure 3.49.16. Disconnect the DC heaterleads from the terminals.17. Set the Volt-Ohm meter to theRx1 scale and measure the resistanceof the DC heater withit at room temperature. The resistanceshould be as indicatedbelow:Figure 3.48DC Element Resistance Reading225 Watt .8 OHMs150 Watt 1.2 OHMsSet volt-ohm meter to the Rx10scale or higher and check theheater element for a short toground. The meter should show nomovement.18. If the heater does not measurewithin ± 5% of the indicatedvalue, it must be replaced.19. A shorted heater will cause theDC fuse to blow.Figure 3.493-20