10.07.2015 Views

Clinical Guidelines for the Safe Use of McKinley T34 Syringe Pump

Clinical Guidelines for the Safe Use of McKinley T34 Syringe Pump

Clinical Guidelines for the Safe Use of McKinley T34 Syringe Pump

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

EQUIPMENT <strong>McKinley</strong> <strong>T34</strong> syringe pump Battery: 6LR61 Duracell MN1604 alkaline or lithium. Plus spare new battery 20 ml, 30 ml or 50 ml luer lock syringe, e.g. Becton Dickinson (BD) <strong>McKinley</strong> infusion set Alcohol wipe Transparent adhesive dressing, e.g. TEGADERM Prescribed medicines I diluents <strong>Syringe</strong> pump prescription I recording sheet I drug labelAUDITAudit requirements and competencies in relation to nursing staff using <strong>the</strong> pumps is <strong>the</strong>responsibility <strong>of</strong> each individual Team Leader. The Team Leaders will evidence that <strong>the</strong>y areauditing <strong>the</strong>se requirements on an annual basis.PROCEDUREMaintenance schedule All syringe pumps must be serviced annually, whe<strong>the</strong>r <strong>the</strong>y have beenused or not. The responsibility <strong>for</strong> <strong>the</strong> annual service / maintenance contract lies with <strong>the</strong><strong>Clinical</strong> Services Manager; however it is <strong>the</strong> responsibility <strong>of</strong> individual Team Leaders(community) to ensure compliance with <strong>the</strong> contract.Additionally, syringe pumps should be sent <strong>for</strong> maintenance checks if <strong>the</strong>y have been droppedor submerged in fluid or if <strong>the</strong>re is any doubt as to <strong>the</strong>ir handling operation whilst out on loan.REGISTER OF MEDICAL DEVICESA register <strong>of</strong> all such devices within Halton & St Helens Primary Care Trust area is maintained.When new syringe pumps are introduced into <strong>the</strong> system or syringe pumps are removed fromservice, <strong>the</strong> Medical Devices Coordinator must be notified according to procedures outlined inHalton & St Helens Primary Care Trust Medical Devices Policy.DECONTAMINATION OF THE MCKINLEY <strong>T34</strong> SYRINGE PUMPDecontamination should be carried out with a damp disposable cloth (use warm water andgeneral-purpose detergent). Dry thoroughly. If any additional cleaning is needed, e.g. <strong>the</strong>threads <strong>of</strong> <strong>the</strong> screws <strong>the</strong> actuator moves along, contact <strong>the</strong> Infection Prevention and ControlTeam <strong>for</strong> advice. The pump must not be submerged in water: if it is accidentally dropped inwater, it must be withdrawn from use immediately and sent <strong>for</strong> repair (Decontamination Policy;Infection Prevention and Control Policy).Page 10 <strong>of</strong> 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!