LABELLINGNo Action Rationale1 All syringes containing drug additives must be labelled To ensure accurate recordkeeping2 If <strong>the</strong>re is any doubt as to <strong>the</strong> contents <strong>of</strong> a syringe, <strong>the</strong>contents should be discarded into denaturing kit.3 Complete <strong>the</strong> label details in black ink or o<strong>the</strong>r indelibleprint. The label requires to state: The name <strong>of</strong> <strong>the</strong> patient <strong>for</strong> whom it is intended; The date and time <strong>of</strong> preparation; The full name <strong>of</strong> <strong>the</strong> person preparing <strong>the</strong>contents; The name and quantity <strong>of</strong> all drugs; The name <strong>of</strong> <strong>the</strong> diluent; The total volume <strong>of</strong> <strong>the</strong> contents; The time period over which <strong>the</strong> contents are tobe infused; The intended route <strong>of</strong> infusion; The date and time <strong>the</strong> infusion started4 Ensure <strong>the</strong> label does not interfere with <strong>the</strong> mechanism<strong>of</strong> <strong>the</strong> infusion device, i.e. where <strong>the</strong>re is contact with<strong>the</strong> barrel clamp arm.5 Attach <strong>the</strong> label to <strong>the</strong> syringe. Ensure that <strong>the</strong> labeldoes not obscure any visuals scales.To ensure that any risks to <strong>the</strong>patient are minimised and tocomply with Halton & StHelens Primary Care TrustPolicy <strong>for</strong> <strong>the</strong> Disposal <strong>of</strong>Controlled Drugs.To ensure accurate recordkeeping.Ensuring safe practice and toprevent malfunctioning <strong>of</strong>pumpTo ensure <strong>the</strong> visual scalescan be viewed during <strong>the</strong>infusionCONNECTING INFUSION SET TO THE SYRINGENo Action Rationale1 <strong>McKinley</strong> infusion sets must be used To ensure <strong>the</strong> correct infusion<strong>for</strong> <strong>the</strong> administration <strong>of</strong>medication via a syringepump.2 Connect it securely to <strong>the</strong> syringe To prevent leakage andwastage <strong>of</strong> medications anddisconnection3 If it is a new infusion set, prime <strong>the</strong> line Prevents time delay in patientreceiving medicationPage 12 <strong>of</strong> 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!