TROUBLESHOOTINGNo Action RationaleIf fast (running more than 1 hour ahead <strong>of</strong> expected time)1 Check <strong>the</strong> rate setting is correct. To ensure pump rate is not set too fast.2 Check <strong>the</strong> correct syringe brand or sizehas been selected.3 Change <strong>the</strong> entire syringe pump <strong>for</strong> a newone and send <strong>for</strong> servicing.To ensure exact calculation by syringepump <strong>of</strong> rate.In order to maintain patient safety and incompliance with NHS Halton & StHelens Medical Devices Policy.4 In<strong>for</strong>m <strong>the</strong> patient’s medical practitioner if<strong>the</strong> patient's clinical condition gives cause<strong>for</strong> concern.5 Report <strong>the</strong> incident through <strong>the</strong> PrimaryCare Trust’s incident reporting system.To obtain expert medical adviceTo ensure compliance with Halton & StHelens Primary Care Trust IncidentReporting Policy.No Action RationaleIf slow (running more than 1 hour behind expected time).1 Check <strong>the</strong> syringe pump light is on. To ensure that <strong>the</strong> pump has power.2 Check <strong>the</strong> battery level. (If battery leveldisplays 40% or below, change battery.)To ensure <strong>the</strong> power level is sufficient tocomplete <strong>the</strong> safe delivery <strong>of</strong> drugs overa 24 hour period.3 Check <strong>the</strong> rate setting is correct. To ensure <strong>the</strong> appropriate dose isdelivered.4 Check <strong>the</strong> correct syringe brand or sizehas been selected.5 Check that syringe is inserted correctly intosyringe pump.6 Ascertain if syringe pump has beenstopped and restarted <strong>for</strong> any reason.7 Check contents <strong>of</strong> syringe and line -is <strong>the</strong>reany evidence <strong>of</strong> crystallisation/kinking <strong>of</strong>tubing8 Check needle site -is this red / hard /lumpy/sore?To ensure exact calculation by pump <strong>of</strong>rate <strong>of</strong> administration.The pump will not work if <strong>the</strong> syringeinserted incorrectly.This will affect <strong>the</strong> functioning <strong>of</strong> <strong>the</strong>pump.This may slow delivery <strong>of</strong> contents.This may affect absorption9 Change needle site if necessary To improve absorption.10 Consider fur<strong>the</strong>r dilution <strong>of</strong> drugs tominimise irritation by setting up a freshTo prevent irritation.Page 20 <strong>of</strong> 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!