Filter elements for liquid filters - MAHLE Industry - Filtration

Filter elements for liquid filters - MAHLE Industry - Filtration

Filter elements for liquid filters - MAHLE Industry - Filtration

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

6.3.1 <strong>Filter</strong> <strong>elements</strong> 852 xxx seriesNominal sizemax. ∆ p <strong>Filter</strong> surfaceNG [l/min] Order number Type <strong>Filter</strong> material [bar][cm²] Used in housing70366315 Mic 10 -78267171 Mic 25 28500on request KS-Mic 25 -79715434 Sm-N 2 2345078227431 PS 3 2850079337916 PS 6 2850078226797 PS 10 28500180078375925 PS 16 28500Pi 1907852 8841078226805 PS 25 28500Pi 281on request Drg 10 -79337460 Drg 25 2345078261653 Drg 40 2345079700402 Drg 60 2345079327750 Drg 100 2345078367393 Drg 250 2345078376204Drg 50023450-7. When should the filter element be replaced? 8. Possibilities of cleaning wire gauge <strong>elements</strong>1 . <strong>Filter</strong>s equipped with visual and electrical maintenanceindicator:During cold starts, the indicator may give a warning signal.Press the red button of the visual indicator once again only afteroperating temperature has been reached. lf the red buttonimmediately pops up again and/or the electrical signal has notswitched off after reaching operating temperature, the filterelement must be replaced after the end of the shift.2 . <strong>Filter</strong>s without maintenance indicator:The filter element should be replaced after the trial run orflushing of the system. Afterwards follow instructions of themanufacturer.3 . Please always ensure that you have original <strong>MAHLE</strong> spare<strong>elements</strong> in stock. Disposable <strong>elements</strong> (Mic, KS-Mic, PS andSm-x) cannot be cleaned .-LEERLEER-LEER-LEER-LEER-LEERLEERLEERLEERLEERLEERLEER<strong>MAHLE</strong> Industriefiltration GmbHSchleifbachweg 45D-74613 ÖhringenPhone +49 7941 67-0Fax +49 7941 67-23429industrialfiltration@mahle.comwww.mahle-industry.com70373334.02/20141. Ultrasonic cleaningImmerse contaminated filter element into the ultrasonic bath <strong>for</strong>approx. 90 – 120 minutes, then flush with clean solvent. Then carefullyblow out filter element from the clean side in outward directionusing compressed air. As solvent, cleaning gasoline etc. may beused.2. Manual cleaningOnly <strong>for</strong> degree of filtration ≥ 40 µm.1 . Remove coarse external dirt with a brush or similar tool in aseparate cleaning container filled with solvent such as cleaninggasoline.2 . Put filter element into a clean <strong>liquid</strong> solvent (approx. 20minutes).3 . Flush filter element with <strong>liquid</strong> solvent from inside to outside.4 . Blow out filter element from the clean side in outward directionusing compressed air.With either method ascertain that no dirt can deposit on the inside(clean side) of the filterelement. Further it needs to be consideredthat the element will not damaged because of proper handling. Anentire cleaning (100 %) cannot be achieved (especially at a grade offiltration≤ 25 µm. The service life of the element will decrease continiouslyper cleaning!<strong>Filter</strong> Elements 22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!