Heating Line <strong>Product</strong> Guide 435.0Thermocouple-Operated Combination <strong>Valve</strong>s Section<strong>Product</strong> Bulletin <strong>G292</strong>Issue Date 0200<strong>G292</strong> <strong>Series</strong> <strong>BASO</strong>® <strong>Dual</strong> <strong>Pilot</strong> <strong>Gas</strong> <strong>Valve</strong>The <strong>G292</strong> <strong>Series</strong> is a dual pilot gas valve intended foruse with a dual burner system that requires acontinuously burning standing pilot at each burner.The <strong>G292</strong> valve can be used with natural gas,Liquefied Petroleum (LP) gas, and LP-air mixed gas atpressures up to 35 mbar (0.5 psi). Typical applicationsinclude commercial cooking applications.Figure 1: <strong>G292</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Dual</strong> <strong>Pilot</strong> <strong>Valve</strong>Features and Benefits❑ <strong>Dual</strong> <strong>Pilot</strong> Design❑ Compact Design❑ Safe Lighting❑ Easy OperationProvides pilot flame for a dual burner systemwith one valvePermits installation in dimensionally-restrictedappliancesAllows gas flow only to the pilot burner duringlightingProvides simple lighting with the use of largereset buttons© 2000 Johnson Controls, Inc. 1Code No. LIT-4350105www.johnsoncontrols.com


<strong>Product</strong> OverviewDescriptionThe <strong>G292</strong> valve is a 100% shutoff device with a compact,cast aluminum valve body. It can be used with a dualburner system to ignite pilot gas for each burner. The flowinterruption feature allows gas to flow only to the pilotduring the lighting process. Models with an optionalmanual rotor “B” valve provide for adjustment of the pilotflame size.MountingThe <strong>G292</strong> valve may be mounted in any convenientposition.Dimensions6.35 Compression0.25 Coupling42.01.746.81.8130.85.1ThermocoupleConnection6.35 Compression0.25 CouplingThermocoupleConnection80.3 Swing3.2 Radius29.01.1111.64.446.81.831.41.267.52.733.71.3107.54.2Figure 2: Dimensions, mm (in.)2 <strong>G292</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Dual</strong> <strong>Pilot</strong> <strong>Gas</strong> <strong>Valve</strong> <strong>Product</strong> Bulletin


4016.03012.0208.06.0F low Capacity m 3 /hPressure Dropmbar1074.02.8Pressure Dropin W.C.52.041.631.020.81Air(sp gr = 1.0)1 2 3 4 5 6 8 10 20 30 40 50 1000.4Natural <strong>Gas</strong>(sp gr = 0.64)1.5 2 3 4 6 10 20 40 60 10050 100 200 300 500 1000 2000 3000m 3 /hcf/hLP -Propane(sp gr = 1.53)1 2 3 4 6 10 20 40 60 10040 50 100 200 300 500 1000 2000 3000m 3 /hcf/hCapacityOrdering InformationInlet/OutletFigure 3: Maximum Flow CapacityG 2 9 2 _ _ - _ _Customer-specific RequirementsRotor “B” <strong>Valve</strong>A = NoB = YesA = 1/2 x 1/2 in. NPTB = 1/2 x 3/4 in. NPTFigure 4: Ordering Matrix<strong>G292</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Dual</strong> <strong>Pilot</strong> <strong>Gas</strong> <strong>Valve</strong> <strong>Product</strong> Bulletin 3


S pecifications <strong>Product</strong>Types of <strong>Gas</strong>Maximum OperatingPressurePermissible AmbientTemperatureBody Connections<strong>Pilot</strong> ConnectionsRecommendedThermocouple LeadLengthsPackagingBulk Pack Quantity 32<strong>G292</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Dual</strong> <strong>Pilot</strong> <strong>Gas</strong> <strong>Valve</strong>Natural, LP, manufactured, mixed, or LP gas-air mixture35 mbar (0.5 psi)<strong>G292</strong>_A Models: -40 to 80°C (-40 to 175°F)<strong>G292</strong>_B Models: 0 to 80°C (32 to 175°F)1/2 in. NPT Inlet x 1/2 in. NPT Outlet1/2 in. NPT Inlet x 3/4 in. NPT Outlet1/4 in. Compression CouplingK15: 305 to 1,220 mm (12 to 48 in.)K16: 305 to 1,830 mm (12 to 72 in.)Bulk pack supplied to original equipment manufacturer (individual pack optional)Agency Listings CSA (AGA/CGA) Certificate Number 112518-0000-000024Specification StandardsANSI Standards, Z21.78 and Z21.78aCanadian Standards, CAN/CGA 6.20 and CAN/CGA 6.20aThe performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyondthese specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resultingfrom misapplication or misuse of its products.Refer to the <strong>G292</strong> <strong>Series</strong> Technical Bulletin (LIT-121196) for necessary information on the installation, use, and servicing of this product.Controls Groupwww.johnsoncontrols.com507 E. Michigan Street FAN 435.0P.O. Box 423Heating Line <strong>Product</strong> GuideMilwaukee, WI 53201Printed in U.S.A.4 <strong>G292</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Dual</strong> <strong>Pilot</strong> <strong>Gas</strong> <strong>Valve</strong> <strong>Product</strong> Bulletin