11.07.2015 Views

McQuay MDS Multi System

McQuay MDS Multi System

McQuay MDS Multi System

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

STNDesign & installation Guide For <strong>McQuay</strong> <strong>MDS</strong> <strong>Multi</strong> <strong>System</strong>Model <strong>MDS</strong>060AR(220V~/50Hz)LNNFU2191817K3K2K1RCEXVPWMV4WVKMK1K2K33 4578101L1 3L25L321PWMV4WVDIG COMPFIXED COMPHI-FANMID-FANLOW-FANKM2T14T26T3 22LIVERY1RY2RY3RY4RY5RY6RY7NNEUTRALblueredbluebrownorangeredbluebrownorangeredJ2NEUTRALPTCC1whiteCRCMSCompressorShaftheaterDescription of components and parts:Symbol DescriptionPTC Compressor start-up unit4WV Four-way valveKM ContactorC1-2 CapacitorHP High pressure switchK1-3 RelaySymbolFUEXVPWMVLPRC1314whiteC2blackFuseM~DescriptionElectric expansion valveSolenoid valveLow pressure switchSurge suppressor1516whiteC3M~blackFan 1 Fan 2Jumper settings DIP switch J2 setting:JP1 JP2 J2.6OFF OFF OFFDIP switch J1 settings:J1.1 J1.2 J1.3 J1.4 J1.5 J1.6 J1.7OFF OFF OFF OFF OFF ON OFFTRAN-HTRAN-LJP1JP2CN1Connecting indoorunit communicationAAI-IN<strong>McQuay</strong>BGNDDLTOD TEMP.J1RTNC-BTMInLetOV-COMP3OV-COMP2OV-COMP1LPHPMidLetOutLet1112LPHPCoil outlettemperature sensor(TH6)Coil middle temperature sensor(TH5)Coil inlet temperature sensor(TH4)Return air temperature sensor(TH3)Ambient temperature sensor(TH2)Notes:Air discharge temperature sensor of the digital compressor(TH1)1: -----------Field wiring2: --------------Factory wiring3: J2.1~2.5 sets the internetworking control address4: If the unit connected at the end of the bus,JP1,JP2 is on.Model <strong>MDS</strong>060AR(380V/3N~/50Hz)RSTNFUL81DB3A7123K322K2yellowgreenred21K1RC71 RDB3A81EXVPWMV4WVKMK1K2K31 23578KMPWMV4WVDIG COMPFIXED COMPHI-FANMID-FANLOW-FANShaftheateryellowgreenredT2T1T3M~DigitalcompressorDescription of components and parts:SymbolDescription SymbolDB3A Reverse phase-loss protector FU4WV Four-way valveEXVKM ContactorPWMVC1-2 CapacitorOLK1-3 RelayLPHP High pressure switchRCOLC11718whiteblackFusebluebrownM~C220 blackFan 1 Fan 2DescriptionElectric expansion valveSolenoid valveOverload protectorLow pressure switchSurge suppressororangered19OL14.0A~ MJP1DIP switch J1 settings:JP2-42-TransformerTransformerDIP switch J2 setting:J2.6J1.1 J1.2 J1.3 J1.4 J1.5 J1.6OFFwhitebluebrownorangeOFFOFFredOverload setting&Jumper settings:OFF OFF OFFOFFOFFONL1NJ1.7OFFLIVENEUTRALTRAN-HTRAN-LJP1JP2CN1Connecting indoorunit communicationRY1AAI-INBRY2<strong>McQuay</strong>GNDDLTRY3Notes:1: -----------Field wiring2: --------------Factory wiring3: J2.1~2.5 sets the internetworking control address4: If the unit connected at the end of the bus,JP1,JP2 is on.OD TEMP.J1RY4RTNJ2RY5C-BTMRY6InLetRY7NEUTRALOV-COMP3OV-COMP2OV-COMP1LPHPMidLetOutLetAmbient temperature sensor(TH2)Air discharge temperature sensor of the digital compressor(TH1)121516OLLPHPCoil outlettemperature sensor(TH6)Coil middle temperature sensor(TH5)Coil inlet temperature sensor(TH4)Return air temperature sensor(TH3)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!