Annex B Application Information for Ampacity Calculation

Annex B Application Information for Ampacity Calculation

Annex B Application Information for Ampacity Calculation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Annex</strong> B: AmpacitiesANNEXBTable B.310.3 Ampacities of Multiconductor Cables with Not More Than Three Insulated Conductors,Rated 0 Through 2000 Volts, in Free Air Based on Ambient Air Temperature of 40°C (104°F)(For Types TC, MC, MI, UF, and USE Cables)Temperature Rating of Conductor. (See Table 310.13.)Size (AWGor kcmil)6O°C(140°F)7S o C 8S o C(167°F) (18S 0 F)COPPER90°C(194°F)60°C 7S o C 8S o C 9O°C(140°F) (167°F) (18S 0 F) (194°F)ALUMINUM OR COPPER·CLAD ALUMINUMSize (AWGor kcmil)18161412108--18*21*28*39--21*28*36*50--24*30*41*5611*16*25*32*43*59---18*21*30---21*28*39---24*30*44---25*32*4618161412108643215269819210768891041181387510011613215479104121138161415463728453708192108597891103120618195108126643211/02/03/04/0124143165190160184213245178206238274186215249287971111291491251441661921391601852141451681942241/02/03/04/025030035040050021223726128132127430633736341630534137740646532035739442548716618620522225521424026528733023926829631736825028030933438525030035040050060070075080090010003543874044154384614595025235395706015135625866046396745385896156336707072843063283393623853684054244394694994104624734905145584294734955135485846007007508009001000Correction FactorsAmbient For ambient temperatures other than 40°C (104°F), AmbientTemp. multiply the ampacities shown above Temp.("C) by the appropriate factor shown below. (oF)21-25 1.32 1.20 1.15 1.14 1.32 1.20 1.15 1.14 70-7726-30 1.22 1.13 1.11 1.10 1.22 1.13 1.11 1.10 79-8631-35 1.12 1.07 1.05 1.05 1.12 1.07 1.05 1.05 88-9536-40 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 97-10441-45 0.87 0.93 0.94 0.95 0.87 0.93 0.94 0.95 106-11346-50 0.71 0.85 0.88 0.89 0.71 0.85 0.88 0.89 115-12251-55 0.50 0.76 0.82 0.84 0.50 0.76 0.82 0.84 124-13156-60 - 0.65 0.75 0.77 - 0.65 0.75 0.77 133-14061-70 - 0.38 0.58 0.63 - 0.38 0.58 0.63 142-15871-80 - - 0.33 0.44 - - 0.33 0.44 160-176'Unless othelWise specifically permitted elsewhere in this Code, the overcurrent protection <strong>for</strong> these conductortypes shall not exceed 15 amperes <strong>for</strong> 14 AWG, 20 amperes <strong>for</strong> 12 AWG, and 30 amperes <strong>for</strong> 10 AWG copper;or 15 amperes <strong>for</strong> 12 AWG and 25 amperes <strong>for</strong> 10 AWG aluminum and copper-clad aluminum.70--692NATIONAL ELECTRICAL CODE2008 Edition

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!