11.07.2015 Views

Technical Manual for the RTCU MX2i eco - Logic IO

Technical Manual for the RTCU MX2i eco - Logic IO

Technical Manual for the RTCU MX2i eco - Logic IO

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Technical</strong> <strong>Manual</strong> 1.03, <strong>RTCU</strong> <strong>MX2i</strong> <strong>eco</strong>Serial port 1 / Programming port.This port can be used as general-purpose RS232 serial port or as a programming port. Inorder to use <strong>the</strong> port <strong>for</strong> programming, <strong>the</strong> RS-DET pin must be connected to GND. Whenusing <strong>the</strong> port as general-purpose RS232, <strong>the</strong> RS-DET pin must be left unconnected.Fur<strong>the</strong>r details on <strong>the</strong> programming cable are available in <strong>the</strong> <strong>RTCU</strong>-IDE online help.X4: 6 pin SER1 connector overview.Pin Name Description1 TD Transmit Data from serial port 1, RS232 compatible4 RD Receive Data <strong>for</strong> serial port 1, RS232 compatible2 RS-DET Programming cable detect, normally unconnected (if programmingcable, connect to GND)5 SGND Signal GroundDC-OutA 3.3VDC output is available on <strong>the</strong> 6 pin serial port 1 connector. It is possible to control<strong>the</strong> output in order to save power. The output is short circuit- (to ground), ESD- andtransient protected.Make sure not exceed <strong>the</strong> current specification of <strong>the</strong> output and be aware of inrushcurrents of <strong>the</strong> external equipment may exceed <strong>the</strong> specifications. It is r<strong>eco</strong>mmended toinstall a fuse to protect <strong>the</strong> output.This output must be enabled from <strong>the</strong> application. Please consult <strong>the</strong> <strong>RTCU</strong>-IDE onlinemanual <strong>for</strong> more in<strong>for</strong>mation.X4: 6 pin SER1 connector overview.Pin Name Description3 DC-Out +3.3V/150mA DC-Out <strong>for</strong> external equipment.5 SGND Signal GroundVibration SensorThe <strong>RTCU</strong> <strong>MX2i</strong> <strong>eco</strong> unit contains a vibration sensor. It makes it possible through <strong>the</strong>power management to detect vibrations when <strong>for</strong> example <strong>the</strong> vehicle is moved. Thesensitivity can be altered from within <strong>the</strong> VPL program - making it suitable <strong>for</strong> variousapplications. Please consult <strong>the</strong> <strong>RTCU</strong>-IDE online manual <strong>for</strong> more in<strong>for</strong>mation.Page 11 of 18<strong>Logic</strong> <strong>IO</strong> ApS. Ph: (+45) 7625 0210Holmboes Allé 14 Fax: (+45) 7625 02118700 Horsens Email: info@logicio.comDenmarkwww.logicio.com / www.rtcu.dk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!