11.07.2015 Views

download - Ilme

download - Ilme

download - Ilme

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

iTMsocket-outletsfor industrial purposeslow voltagedrawing ILME description packagingpart No.16A• in compliance with standards EN 60309-1, -2 and - 4• enclosures in insulating thermoplastic selfextinguishingmaterial MIL.BOX ® moulded withBC-MUL ® technique, colour grey RAL 7012• with bayonet jointed lid• padlockable handle, both in O and I position• mechanical resistance to impacts: 20 J (IK 10according to EN 62262)interlocked switched socket-outlets with screw-type fuse carrierswithout back box*• double mechanical interlock that preventsfrom: switching ”ON” the switch when theplug is not inserted, withdrawing the plugwhen the switch is turned to ”ON” position• the switch cannot be switched ON until thefuse carriers’ cover has been closed• q with Italian Quality Markfuse links not includeddegree of protection IP66/IP67 (EN 60529) - the sockets are supplied not pierced,therefore their degree of protection will change according to the connectingadapter mounted on the boxes.100÷130V ~ - 50 and 60 Hz - yellowTM 1643 SIT 16A - 2P + m - 4h •- fuse carriers E16 - q 1TM 1644 SIT 16A - 3P + m - 4h •- fuse carriers E16 - q 1TM 1645 SIT 16A - 3P + N + m - 4h •- fuse carriers E16 - q 1200÷250V ~ - 50 and 60 Hz - blueTM 1663 SIT 16A - 2P + m - 6h •- fuse carriers E16 - q 9TM 1694 SIT 16A - 3P + m - 9h •- fuse carriers E16 - q 1TM 1695 SIT 16A - 3P + N + m - 9h •- fuse carriers E16 - q 9380÷415V ~ - 50 and 60 Hz - redTM 1693 SIT 16A - 2P + m - 9h •- fuse carriers E16 - q 1TM 1664 SIT 16A - 3P + m - 6h •- fuse carriers E16 - q 9TM 1665 SIT 16A - 3P + N + m - 6h •- fuse carriers E16 - q 9480÷500V ~ - 50 and 60 Hz - blackTM 1674 SIT 16A - 3P + m - 7h •- fuse carriers E16 - q 1TM 1675 SIT 16A - 3P + N + m - 7h •- fuse carriers E16 - q 1 The articles with hour position 6h refer to the rated voltage (2P+m/220÷250V ~ - 3P+m and 3P+N+m/380÷415V ~)spare switchesfor TM..SIT socketsPKR 432 4 x 32A - for 16A sockets - 3/4/5 poles 1By end 2010 available with sectionable fuse carrier only.See page 34TMNEWsocket-outlets with safety transformer - 144 VA continuous servicewithout back box*for class III lighting apparatusin compliance with standard EN 60742 (class. CEI 96-2)degree of protection IP66/IP67 (EN 60529)with bayonet jointed lidprimary switched by plug insertionself-protected toroidal transformer with automatic re-startaccording to EN 60742 - 144 VA continuous serviceTM 16220 ST1 16A - 2P •- 24V~ - 50 and 60 Hz - transf. 230/24V 2TM 16380 ST1 16A - 2P •- 24V~ - 50 and 60 Hz - transf. 400/24V 2* To install the TM..SIT and TM..ST1 they have to be prior mounted in a single or multiple box16AAccessories for set mountingTM 1125 CS(page. 37)TM 2344 T2TM 2318 P2(page. 37)TM 3444 T3TM 3418 P3(page. 37)(page. 37)TM 2318 R2(page. 37)(page. 37)TM 3418 R3(page. 37)For technical data-sheet and further information please look at our technical catalogues on website www.ilme.com33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!