11.07.2015 Views

Seko Measuring and Control I.. - UK

Seko Measuring and Control I.. - UK

Seko Measuring and Control I.. - UK

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

h photometric method, pH, Redox <strong>and</strong> TemperatureProbe holderClean water inletSpecial Outlet forwater with DPDreagentClean wateroutletl Hydraulics with outlet of water containing reagents forchlorine measurement. This allows a considerable reduction inthe quantity of water used for the measurement. The water usedfor checking the pH <strong>and</strong> Redox can be channelled towards thebuffer tank, while only the water polluted by the DPD reagents willbe drained off <strong>and</strong> managed separately in accordance with localregulationsl Installation time reduced thanks to quick-couplingconnections for sampling <strong>and</strong> outlet pipesl The unit has self-calibration for optical unit <strong>and</strong> ensures a highlevel of Chlorine measurement precision using a 520 nmsensor <strong>and</strong> light source emitted by a LEDTechnical FeaturesFree or Total Chlorine Measurement 0÷ 5 ppm Resolution 0,01 ppm Precision 1% FSpH Measurement 0÷14 pH Resolution 0,01 pH Precision 1% FSRedox Measurement ±1500 mV Resolution 1 mV Precision 1% FSTemperature Measurement 0÷50 °C (32 ÷ 106 °F) Resolution 0.1°C (.18 °F) Precision 1% FSDisplayProgrammingDigital InputAnalogue InputPower supplyInternal Data Logger240x128 pixel backlit graphicVia keypad with 4 bubble keysDry contact for disabling dosages0/4÷20 mA for auxiliary measurements90÷264Vac 50-60Hz 66 WattFlash Memory 16000 recordsRecording interval 00:00 ÷ 99:99 minutesType circular / refillTabular / graphic display4 Analogue Outputs Size Chlorine, pH, Redox, TemperatureType 0/4÷20 mA galvanically isolatedLower / upper / inversion limit programmingMaximum load 500 Ohms4 Set Point Relay Outputs nr. 2 for chlorine measurement + nr. 2 for pH measurementMax. relay load 3A (resistive) 230VacAlarm Relay OutputLack of sample waterReagents run outFloodlight burned outDirty cellRelay max. resistive load 3A at 230Vac2 Auxiliary Relay Outputs Programmable as Set Points for Redox measurement, Set Points for Temperaturemeasurement, Timed activation for cell cleaningRelay max. resistive load 3A at 230VacSerial Port Output (RS485) RTU MODBUS protocol with programmable Baud rate 1200 ÷ 38400Available versionTotal Chlorine + TemperatureFree Chlorine + TemperatureFree Chlorine+ pH + TemperatureFree Chlorine + pH + Redox + Temperatureinnovation > technology > future 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!