3 TON - 6 TON CPC/CPH SERIES - Goodman

3 TON - 6 TON CPC/CPH SERIES - Goodman

3 TON - 6 TON CPC/CPH SERIES - Goodman

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

COOLINGEVAPORATORINDOORCOILSERVICE VALVESERVICE PORTCOMPRESSORDISTRIBUTOREXPANSION DEVICECHECK VALVEORIFICE SERVICEVALVESERVICE PORTACCUMULATORSERVICE PORTCHECK VALVEORIFICEREVERSING VALVECONDENSEROUTDOORCOILDEFROST CONTROLDuring operation the power to the circuit board is controlledby a temperature sensor, which is clamped to a feeder tubeentering the outdoor coil. Defrost timing periods of 30,60 and90 minutes may be selected by setting the circuit board jumperto 30, 60 and 90 respectively. Accumulation of time for thetiming period selected starts when the sensor closes (approximately31° F), and when the wall thermostat calls forheat. At the end of the timing period, the unit’s defrost cyclewill be initiated provided the sensor remains closed. Whenthe sensor opens (approximately 75° F), the defrost cycle isterminated and the timing period is reset. If the defrost cycleis not terminated due to the sensor temperature, a twelveminute override interrupts the unit’s defrost period.HEATINGCONDENSERINDOORCOILSERVICE VALVECOMPRESSORDISTRIBUTORCHECK VALVEORIFICE SERVICEVALVESERVICE PORTACCUMULATORSERVICE PORTCHECK VALVEORIFICEREVERSING VALVEDISTRIBUTOREVAPORATOROUTDOORCOILWhen the heat pump is on the heating cycle, the outdoor coilis functioning as an evaporator. The temperature of the refrigerantin the outdoor coil must be below the temperature ofthe outdoor air in order to extract heat from the air. Thus, thegreater the difference in the outdoor temperature and theoutdoor coil temperature, the greater the heating capacity ofthe heat pump. This phenomenon is a characteristic of aheat pump. It is a good practice to provide supplementaryheat for all heat pump installations in areas where the temperaturedrops below 45° F. It is also a good practice toprovide sufficient supplementary heat to handle the entireheating requirement should there be a component failure ofthe heat pump, such as a compressor, or refrigerant leak,etc.Since the temperature of the refrigerant in the outdoor coil onthe heating cycle is generally below freezing point, frost formson the surfaces of the outdoor coil under certain weather conditionsof temperature and relative humidity. Therefore, it isnecessary to reverse the flow of the refrigerant to provide hotgas in the outdoor coil to melt the frost accumulation. This isaccomplished by reversing the heat pump to the cooling cycle.At the same time, the outdoor fan stops to hasten the temperaturerise of the outdoor coil and lessen the time requiredfor defrosting. The indoor blower continues to run and thesupplementary heaters are energized.AIR FLOW ADJUSTMENTSThe drive on the supply fan is typically set in the middle of theRPM range. The drive motor sheave pitch diameter is fieldadjustable for the required airflow. Refer to “DriveAdjustments” section below.When the final adjustments are complete, the current drawof the motor should be checked and compared to the fullload current rating of the motor. The amperage must not exceedthe service factor stamped on the motor nameplate.The total airflow must not be less than that required for operationof the electric heaters or the furnace.If an economizer is installed, check the unit operating balancewith the economizer at full outside air and at minimumoutside air. Upon completion of the air flow balancing, werecommend replacing the variable pitched motor sheave witha properly-sized fixed sheave. A matching fixed sheave willprovide longer belt and bearing life and vibration free operation.Initially, it is best to have a variable pitched motor sheavefor the purpose of airflow balancing, but once the balancehas been achieved, fixed sheaves maintain alignment andminimize vibration more effectively. For direct drive units, movegreen wire for fan.NOTE: Never run CFM below 350 CFM per ton, evaporatorfreezing or poor unit performance is possible.PSC MOTORAdjust the CFM for the unit by changing the speed tap of theindoor blower motor at the EBTDR “com” connection with theone of the speed taps on “M1” or “M2” (Black-High Speed,Blue-Medium Speed, Red-Low Speed).X-13 MOTORAdjust the CFM for the unit by changing the position of thelow voltage leads on the motor terminal block. Green is forFan Only. Yellow is for Cooling and Heat Pump Heating. Referto Appendix A for blower performance at each speed tap.NOTE: If more than one lead is energized simultaneously,the motor will run at the higher speed.14

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!