Technical SpecificationsAccuracy: < +2% of FS range under constant conditionsAnalysis: 0-100% oxygenApplication: Verify ambient O 2 levels of confined spacesCalibration: Certified dry 100% oxygen or air after 8 hrs of useCompensation: TemperatureConnections: 1x16 mm thread (see options below)Controls: Soft touch keypad for ON/OFF and CalibrationDimensions: 2.72” x 4.1” x 1.35”; weight 7 oz. (196 grams)NEWDisplay: 3 digit LCD 1.1” x .625”; resolution 0.1% O 2Flow Sensitivity: None between 0.2 to 10 liters per minuteHumidity: Non-condensing 0-95% RHLinearity: + 1% under constant conditionsPressure: Inlet - ambient or regulated; vent - atmosphericPower:(2) 1.5V AA alkaline batteries; 13,000 hrs of useResponse Time: 90% of final FS reading in 10 secondsSensitivity: < 0.5% of FS rangeSensor:AII-11-75-P<strong>O2</strong>Sensor Life: 32 months in air at 25ºC and 1 atmosphereStorage Temp.: -20º to 60ºC (-4ºF to 140ºF) on intermittent basisTemp. Range: 5º to 45ºC (41ºF to 113ºF)Warm-up Time: NoneWarranty: 12 months analyzer; 12 months sensorOptions & AccessoriesAII-11-75-P<strong>O2</strong>R Remote <strong>Oxygen</strong> Sensor KitA-3676-1 Hand Pump KitA-3388 Adapter, Dome to SensorA-3609 Adapter, 1/8” Tube to DomeA-3676 Adapter, 1/8” Tube to SensorFITN-1009 Tee AdapterFITN-1112-1 Flow DiverterHRWR-1157 ScrewdriverHRWR-1158 LanyardPUMP-1020 Hand PumpTUBE-1018 Tubing, 1/8” x 3’A-3657-1 Dovetail Mounting KitHRWR-1075 Dovetail Clamp Pole or Shelf<strong>Palm</strong> O 2<strong>Oxygen</strong> <strong>Analyzer</strong>Easy user interface . . . one touch controlsSimple to use . . . accurate reliable resultsOne touch calibration . . . 100% <strong>O2</strong> or airLong battery life . . . 13,000 hrs of useAdvanced sensor technologyInternal or external sensor configurationsState of the art electronicsCertified ISO 9001:2008 QA SystemISO 9001:2008 CertifiedINTERTEK Certificate No. 4852855 Metropolitan Place, Pomona, CA 91767 USA ♦ Tel: 909-392-6900, Fax: 909-392-3665, www.aii1.com, e-mail: sales-industrial@aii1.com Rev 6/12


<strong>Palm</strong> O 2<strong>Oxygen</strong> <strong>Analyzer</strong>NEWEasy user interface . . . one touch controlsSimple to use . . . accurate reliable resultsOne touch calibration . . . 100% <strong>O2</strong> or airLong battery life . . . 13,000 hrs of useAdvanced sensor technologyInternal or external sensorState of the art electronicsCertified ISO 9001:2008 QA SystemApplicationsPersonnel SafetyArea Monitoring<strong>O2</strong> Deficiency Confined SpacesCheck Breathing Air TanksConfirm <strong>O2</strong> Levels Prior to WeldOptional Accessories<strong>Palm</strong> <strong>O2</strong> R <strong>Oxygen</strong> <strong>Analyzer</strong>, Remote <strong>Oxygen</strong> SensorFor added flexibility select from the standardconfiguration with integral oxygen sensor orthe optional remote sensor . . .either way there is a variety of samplingoptions available to meet your need.<strong>Oxygen</strong> <strong>Analyzer</strong> with A-3654 CABL-1009 Cable 6 ft. AII-11-75-P<strong>O2</strong>R I/WRemote Sensor Connector Phone Plug with Lock Nut <strong>Oxygen</strong> SensorHRWR-1157 ScrewdriverHRWR-1158 LanyardTemporary Mounting in a Fixed Location:2855 Metropolitan Place, Pomona, CA 91767 USA ♦ Tel: 909-392-6900, Fax: 909-392-3665, www.aii1.com, e-mail: sales-industrial@aii1.com Rev 6/12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!