11.07.2015 Views

Geared motors

Geared motors

Geared motors

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Selection tables - Helical gearboxesGearbox with mounting flange for IEC standard <strong>motors</strong>M 2 perm ≤ 707 Nm3GST 07 - 2 N Dimensions page 3-132n 1 2800 min-1 1400 min-1 700 min-1IEC connection80 90 100/112 100/112 132 160 80 90 100/112 100/112 132 160 80 90 100/112 100/112 132 16071 80 80/90 90 100/112 132 71 80 80/90 90 100/112 132 71 80 80/90 90 100/112 132For the geometrical assignment of servo/DC <strong>motors</strong> see section 2Drive size òC òD òE òF òG òH òC òD òE òF òG òH òC òD òE òF òG òHi P 1perm [kW]M 2perm [Nm]3.048 P 1 10.7 28.3 28.3 6.60 17.4 17.4 4.40 8.71 8.71M 2 108 285 285 133 351 351 177 351 3513.350 P 1 10.7 26.9 26.9 6.60 16.5 16.5 4.40 8.27 8.27M 2 119 298 298 146 367 367 195 367 3674.225 P 1 10.7 23.1 23.1 6.60 14.2 14.2 4.40 7.11 7.11M 2 150 323 323 184 398 398 246 398 3984.643 P 1 10.7 21.9 21.9 6.60 13.5 13.5 4.40 6.74 6.74M 2 165 336 336 203 414 414 270 414 4145.200 P 1 10.7 10.7 20.2 20.2 6.60 6.60 12.4 12.4 4.40 4.40 6.21 6.21M 2 184 184 347 347 227 227 427 427 303 303 427 4275.714 P 1 10.7 10.7 19.3 19.3 6.60 6.60 11.9 11.9 4.40 4.40 5.93 5.93M 2 203 203 364 364 249 249 448 448 333 333 448 4486.400 P 1 10.7 10.7 17.8 17.8 6.60 6.60 10.9 10.9 4.40 4.40 5.47 5.47M 2 227 227 376 376 279 279 463 463 373 373 463 4637.150 P 1 10.7 16.8 16.8 6.60 10.3 10.3 4.40 5.16 5.16M 2 254 397 397 312 488 488 416 488 4888.125 P 1 10.7 16.3 16.3 6.60 10.0 10.0 4.40 5.01 5.01M 2 288 438 438 355 539 539 473 539 5398.800 P 1 10.7 10.7 14.7 14.7 6.60 6.60 9.05 9.05 4.40 4.40 4.53 4.53M 2 312 312 428 428 384 384 527 527 512 512 527 5279.856 P 1 10.7 10.7 13.7 13.7 6.60 6.60 8.42 8.42 4.21 4.21 4.21 4.21M 2 349 349 446 446 430 430 549 549 549 549 549 54911.200 P 1 10.7 10.7 13.1 13.1 6.60 6.60 8.07 8.07 4.04 4.04 4.04 4.04M 2 397 397 486 486 489 489 598 598 598 598 598 59812.571 P 1 3.75 10.7 10.7 11.7 2.31 6.60 6.60 7.22 1.54 3.61 3.61 3.61M 2 156 446 446 488 192 549 549 600 256 600 600 60014.286 P 1 3.75 10.7 10.7 11.0 2.31 6.60 6.60 6.79 1.54 3.39 3.39 3.39M 2 177 507 507 521 218 624 624 642 291 642 642 64215.400 P 1 11.7 11.7 11.7 6.32 6.32 6.32 3.16 3.16 3.16M 2 594 594 594 644 644 644 644 644 64417.500 P 1 10.8 10.8 10.8 5.87 5.87 5.87 2.93 2.93 2.93M 2 627 627 627 680 680 680 680 680 68020.044 P 1 4.26 9.65 9.65 2.31 5.23 5.23 1.54 2.62 2.62M 2 283 640 640 306 694 694 408 694 69422.778 P 1 4.26 8.35 8.35 2.31 4.52 4.52 1.54 2.26 2.26M 2 321 629 629 348 682 682 464 682 68224.567 P 1 4.26 8.01 8.01 2.31 4.34 4.34 1.43 2.17 2.17M 2 346 651 651 375 706 706 465 706 70627.917 P 1 4.26 6.90 6.90 2.31 3.74 3.74 1.43 1.87 1.87M 2 394 638 638 427 691 691 529 691 69132.267 P 1 3.11 4.14 6.10 1.69 2.24 3.31 0.84 1.12 1.65M 2 332 442 651 360 479 706 360 479 70636.667 P 1 3.11 4.14 5.34 1.69 2.24 2.89 0.84 1.12 1.45M 2 377 502 648 409 544 702 409 544 702Thermal power limit not considered (see page 2-4)3-74 G-motion const en 11/2004

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!