Drive dimensioningDimensioningPower deratingEffect of the installation heightHow the installation height above mean sea level affectsrated powerH [m] ≤ 1000 2000 3000 4000P hP r1 0.95 0.90 0.85Effect of the ambient operating temperatureHow the ambient operating temperature T amb affectsrated powerT amb [°C] ≤ 40 45 50 55 60P P r1 0.95 0.90 0.85 0.80Calculating the derated powerP red = P h · P · P r Pr P r 2Torque deratingTorque derating dependent upon motor frame sizewith self-ventilation and operation on frequency inverterMM r1MM r10.920.70.60.50.40.25Motor frame size063...071080C32080-11...080-13080-31...080-33090...100112...132160...1800.840.5Motor frame size 080C42200...22520 Hz 40 HzFrequency inverter output frequency14.5 Hz 20 Hz 30 Hz 40 HzFrequency inverter output frequencyG-motion const en 11/20042-3