11.07.2015 Views

Hydro 2000

Hydro 2000

Hydro 2000

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical data<strong>Hydro</strong> <strong>2000</strong> SCR 15Electrical data, weights and dimensionsNo. ofpumps23456Full-size pumpsPump typeMotor[kW]Half-size pumpsPump typeMotor[kW]ConnectionB[mm]L[mm]<strong>Hydro</strong> <strong>2000</strong> MSH[mm]Weight[kg]Max.I n [A]L[mm]<strong>Hydro</strong> <strong>2000</strong> MSHH[mm]Weight[kg]CR 15-2 2.2 CR10-3 1.1720 766 176 9.6 720 766 178 7.5CR 15-3 3.0 CR10-4 1.5 870 186 12.8 870 190 9.8CR 15-4 4.0 CR10-6 2.2 - - - - 1310 952 224 12.8CR 15-5 4.0 - 1310 997 257 16.0 - - -CR 15-6 5.5 CR10-9 3.0DN 80 1039- - - - 1310 1093 255 17.4CR 15-7 5.5 - 1310 1138 295 22.0 - - -CR 15-8 7.5 CR10-12 4.0 - - - - 1310 1183 272 23.2CR 15-9 7.5 - 1310 1228 305 30.4 - - -CR 15-10 11.0 CR10-14 5.514101423 360 43.01410Max.I n [A]1423 318 32.5CR 15-2 2.2 CR10-3 1.1766 276 14.4766 273 12.313701430CR 15-3 3.0 CR10-4 1.5 870 291 19.2 870 287 16.2CR 15-4 4.0 CR10-6 2.2 - - - - 1630 952 327 20.8CR 15-5 4.0 - 1570 997 355 24.0 - - -CR 15-6 5.5 CR10-9 3.0DN 100 1064- - - - 1630 1093 384 28.4CR 15-7 5.5 - 1570 1138 402 33.0 - - -CR 15-8 7.5 CR10-12 4.0 - - - - 1630 1183 417 38.4CR 15-9 7.5 - 1570 1228 433 45.6 - - -CR 15-10 11.0 CR10-14 5.518101423 551 64.5 1810 1423 488 54.0CR 15-2 2.2 CR10-3 1.1766 355 19.2766 349 17.117501950CR 15-3 3.0 CR10-4 1.5 870 377 25.6 870 365 22.6CR 15-4 4.0 CR10-6 2.2 - - - - 2130 952 445 28.8CR 15-5 4.0 - 1950 997 476 32.0 - - -CR 15-6 5.5 CR10-9 3.0DN 100 1064- - - - 2130 1093 528 39.4CR 15-7 5.5 - 1950 1138 562 44.0 - - -CR 15-8 7.5 CR10-12 4.0 - - - - 2130 1183 577 53.6CR 15-9 7.5 - 1950 1228 582 60.8 - - -CR 15-10 11.0 CR10-14 5.522101423 729 86.0 2410 1423 683 75.5CR 15-2 2.2 - -2270 766 463 24.0 - - - -CR 15-3 3.0 - - 870 488 32.0 - - - -CR 15-5 4.0 - -997 601 40.0 - - - -DN 150 1118 2450CR 15-7 5.5 - - 1138 711 55.0 - - - -CR 15-9 7.5 - - 1228 738 76.0 - - - -CR 15-10 11.0 - - 1680 1423 826 107.5 - - - -CR 15-2 2.2 - -2570 766 539 28.8 - - - -CR 15-3 3.0 - - 870 569 38.4 - - - -2770CR 15-5 4.0 - -997 696 48.0 - - - -DN 150 1118CR 15-7 5.5 - - <strong>2000</strong> 1138 731 66.0 - - - -CR 15-9 7.5 - - 1228 761 91.2 - - - -CR 15-10 11.0 - -For information about . and . please see page 98.23601423 987 129.0 - - - -44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!