4<br />

Type 42E20108A04<br />

Options<br />

Please enquire by contacting:<br />

office@kendrion.com<br />

Phone: +43 (0) 34 66 42 3 22 21<br />

Fax: +43 (0) 34 66 42 7 32<br />

or your local partner<br />

Design<br />

Pin connection. Protection type: IPOD<br />

to IEC 60529<br />

Insulation class E<br />

to DIN VDE 580/07.2000<br />

The magnetic forces indicated are for<br />

devices at operating temperature and<br />

for 90% of the rated voltage. They are<br />

achieved when moving horizontally and<br />

apply for a supply voltage of 4.5V DC.<br />

Other voltages and stroke adjustments<br />

are available at a surcharge.<br />

Different supply voltages may lead to<br />

magnetic forces higher or lower than<br />

the specified values owing to the changing<br />

copper factor.<br />

Unenergised<br />

Stroke holding force<br />

(in mm) (in N)<br />

0 0.1<br />

2.5 0.05<br />

direct current bistable miniature linear solenoids<br />

Dimensions<br />

Marking<br />

Position: I<br />

Stroke<br />

Bistable direct current miniature linear solenoids<br />

Bistable direct current miniature linear solenoids are<br />

double-action linear solenoids for short term and<br />

intermittent duty. After the response phase the<br />

integral permanent magnets hold the plunger in the<br />

end position with a specific holding force in the<br />

unergenised state.<br />

The electromagnetic force is used essentially for the<br />

linear movement and the permanent magnetic force<br />

to hold the plunger in the end position without the<br />

use of electrical energy.<br />

The return movement (overcoming the force of the<br />

permanent magnets) is triggered by a reversed,<br />

possibly lower, voltage impulse depending on the<br />

magnitude of an external return force.<br />

Typical starting current: 0.3 A<br />

Minimum release current: 0.2 A<br />

Maximum release current: 0.4 A<br />

Note:<br />

No characteristic curve is given for this type.<br />

This bistable direct current linear solenoid has very limited force and is switched backwards and forwards between<br />

the two end positions.<br />

www.kendrionmt.com<br />

Position: II<br />

The integral return spring moves the plunger back to<br />

the start position.<br />

The customer can fix the solenoid can be fixed in<br />

position by attachment screw on the external diameter.<br />

Parts at risk of corrosion are electro-galvanised to<br />

EN 12329. The plunger is electro-plated with nickel<br />

to EN ISO 4526.<br />

The holding forces of the permanent magnets in the<br />

de-energised state are also reached at the operating<br />

temperature.