11.07.2015 Views

COMfor.adapt.E350 Residential Meter Landis+Gyr E350 Integrated ...

COMfor.adapt.E350 Residential Meter Landis+Gyr E350 Integrated ...

COMfor.adapt.E350 Residential Meter Landis+Gyr E350 Integrated ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong><strong>Residential</strong> <strong>Meter</strong><strong>Landis+Gyr</strong> <strong>E350</strong> <strong>Integrated</strong> inthe Smart <strong>Meter</strong>ing SystemThe communication <strong>adapt</strong>er<strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong> seamlessly integrates theresidential meter <strong>E350</strong> from <strong>Landis+Gyr</strong> inthe IDSpecto.AMM Smart <strong>Meter</strong>ing Systemand enables data transfer from the meterto the Echelon Networked Energy Services(NES) System. The open standard system NESis a core element of the GÖRLITZ - Smart<strong>Meter</strong>ing Solution specifically tailored to therequirements for a rollout of intelligent meters.


IDSpecto.AMM with its Smart <strong>Meter</strong>ing Solution focuses on a worldwide proven technology. The Echelon NES meteringsystem connected as head-end-system has given evidence to be suitable for mass deployment in several large scale projectswith more than 3.8 million residential meters. Standards are consistently used such as the recognised OSGP protocol.Additional meters of different sectors can be connected via multi-purpose expansion port (MEP) and smart home interfacesare made available. The IDSpecto.AMM Smart <strong>Meter</strong>ing System provides secure end-to-end smart metering and optimisedsupport for mass and partial rollout.Benefits of the NES system can now be implemented in the residential meter <strong>E350</strong> from <strong>Landis+Gyr</strong>. The communicationmodule <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong> integrates the meter in the Echelon NES system. Via secure interface, data are provided to IDSpectofor further processing. The added values of the IDSpecto.AMM complete system can thus be used without restrictions.The <strong>COMfor</strong>.<strong>adapt</strong> <strong>E350</strong> permits the application of field technology <strong>E350</strong> from <strong>Landis+Gyr</strong> and unrestricted use of thefollowing IDSpecto.AMM functions:- Support of Automated Topology Management (ATM)Communication with the electricity meter <strong>Landis+Gyr</strong> <strong>E350</strong> is effected via manufacturer-specific serial interface whichis integrated in the meter housing when implementing the <strong>COMfor</strong>.<strong>adapt</strong><strong>E350</strong>. Previous software or hardware updateis not required for installation in the field. Immediately after inserting the communication module <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong>,full support of the Automated Topology Management (ATM) is available. This function can be configured for specificuser requirements. The meter is automatically detected by a concentrator and created via the NES system in theIDSpecto.AMM, and as optionally integrated in daily routine reading. A further option enables the interlinking withan existent device in the IDSpecto.AMM.- Support of wired or wireless M-Bus for max. 4 devicesParallel to this, optionally one connection for max. 4 wired M-Bus devices or remote collection of 4 wireless M-Bus devicesis intended. Initial operation of M-Bus meters for gas, water, heat is a simple routine on site. Similarly, the concept appliesto wireless M-Bus devices compliant to OMS. Required encoding processes and security demands are fully implemented.- Optional switching of relay output, load limitation and remote switching and end user interfaceThe communication module extends the <strong>E350</strong> with a relay output for general switchings. Switching programmes can beestablished and cyclically updated both by the control station and on site. This provides an effective ripple control option.In addition, the <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong> can be extended with an end-user interface. In combination with the IDSpecto.enVIEWapp, the interface offers the visualisation of energy consumption data. Live /real time data and historical data may bedisplayed on mobile devices such as iPhone, iPad or as app.- Creating load profile data for visualisation of energy consumption and analysing purposesThe <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong> optionally creates a load profile for visualising energy consumptions. Configuration hereof issent to the communication module through the IDSpecto.AMM. The module ensures periodic reading and creation ofthe load profile.- Provision of new tariffs via remote configuration and forwarding of event and alarm messages(e.g. in case of tampering attempts)The <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong> manages as a link between metering point and control station, standard smartmetering processes in pull and push operation. The operation of the <strong>E350</strong> follows the uniform handling concept of theIDSpecto.AMM. Consequently, daily operations are simplified since presentation and administration of the smart meterremain the same, independent from the manufacturer. And thus, subsequent processes become more efficient.Technology(Subject to modification)Housing:Communication module for <strong>Landis+Gyr</strong> <strong>E350</strong>; protection type IP51 (when integrated); protection class II;protective insulation; dimensions approx. 95 x 165 x 45 mm (L x W x H); weight approx. 300 gPollution degree: 2, compliant with DIN EN 60950-1Over-voltage category: IIIStorage temperature range: -25°C ... +70 °C (EN60721-3-3 Tab. 1, 2K3)Operating temperature range: -10°C ... +55 °CRelative air humidity range: 0 % - 95 %, non-condensingProtection class:IIApproval / tests:• Conformity: CE-conformity• EMC Directive 2004/108/EG• Low-Voltage Directive 2006/95/EG (for wM-Bus versions)• R&TTE Directive 1999/5/EG (for wM-Bus versions)• RoHS Directive 2011/65/EU• interference emission in accordance with EN 55022 Class B• interference emission in accordance with DIN EN 61000-6-3• interference resistance in accordance with DIN EN 61000-6-2• DIN EN 43863-1, general requirements / product standard• DIN EN 50470-1, -3 with respect to insulation requirements for device combinationLandis&Gyr <strong>E350</strong> / <strong>COMfor</strong>.<strong>adapt</strong>.<strong>E350</strong>• Security in accordance with DIN EN 60950-1 (product standard of R&TTE and low voltage RL)• Standard concept IEC 61000-4-19 (compare DKE circular letter 767.1 2012-2009),interference resistance 2 kHz - 150 kHz. Yes, with evaluation criterion B• DIN EN 50065-1, signal transmission on electrical low voltage grids, frequency range3 kHz - 148,5 kHz - part 1: General requirements, frequency bands and electro-magnetic interferences• DIN EN 50065-2-3, signal transmission on electrical low voltage grids in the frequency range3 kHz - 148,5 kHz - part 2-3: Requirements on interference resistance for grid data transmissiondevices and systems, operated in frequency range 3kHz -95kHz and determined for electricity supplyand distribution companies• DIN EN 50065-7, signal transmission on electrical low voltage grids, frequency range3 kHz - 148,5 kHz - part 7: Device impedancesRemote communication: PLC according to CENELEC A-Band, BPSK modulation with two frequencies: 86 kHz primary frequency,75 kHz secondary frequencyInterfaces/Connection Technology:Inputs and buttons:Outputs:Supply voltage:Battery:Operating system:Data memory:Data preservation:Device clock:Load profile recording:Self-reading:<strong>Meter</strong> interface: Manufacturer-specific interface of <strong>Landis+Gyr</strong> <strong>E350</strong>M-Bus master interface according to EN13757-2 (EN1434), EN13757 for max. 4 devices/standard loads (optional)Ethernet ® 10 Base-T, 100 Base-TX according to IEEE 802.3, RJ45 socket (8P8C)Wireless M-Bus (optional)• Specification: standard EN13757-4:2005, wireless M-Bus OMS S-, T, R2 and C mode• sensitivity: max. -106 dBm• transmitting power: max. 9 dBm• frequency range: 868 - 870 MHz• antenna connection: MCX socket (50 Ohm)• transmission range: open air coverage max 350 m, within facility generally 10 - 30 m• Service buttons: buttons for M-Bus meter start up• Unlock key: unlock disconnecting device of <strong>Landis+Gyr</strong> <strong>E350</strong>Relay output with potential-free contact (optional)230 V 50 Hz AC, via <strong>Landis+Gyr</strong> <strong>E350</strong> (power supply over clip spring); power consumption approx. 8 WLithium battery with power reserve for device clock at voltage-free status > 8 years from installation on siteARM microprocessor system with embedded Linux256 Mbyte flash memory; 128 Mbyte RAM memoryData preservation through non-volatile flash memory technologyInternal real-time clock; accuracy type 8 ppm; power reserve min. 8 years, synchronisation via NES systemCollection of max. 16 load profiles, flexible measurement period duration of 5, 10, 15, 20, 30, 60 minutes,or 1 day (example: storage of 46 days load profile with 15-minute-interval or storage of 3 days 16 loadprofiles with 15-minute-interval)Automated self-reading, periodically configurable. Storage of maximum 36 readings

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!