[c] SEQUENCE1st Cycle1. Unit energized and Control Switch to “ICE”position. Water supply cycle starts.3. Thermistor reads 48° F.Defrost Timer starts counting.2. After 1 minute,Defrost cycle starts.&IMPORTANTWater Valveopening is limitedto 6 minutes.5. After the first 5 minutes in freeze cycle.Ready to complete freeze cycle when FloatSwitch circuit opens.IMPORTANTBoard never accepts freeze completion signalwithin the first 5 minutes in freeze cycle.4. Defrost Timer stops counting.Defrost cycle is completed and freeze cyclestarts.IMPORTANT1. Board never accepts defrost completionsignal within the first 2 minutes in defrostcycle.2. Defrost cycle time is limited to 20 minuteseven if Defrost Timer does not stop counting.20