4. PERFORMANCE DATA[a] KM-900MAHAPPROXIMATE ICEPRODUCTION PER 24 HR.AMBIENT TEMP.WATER TEMP. (ºF/ºC)(ºF/ºC) 50/10 70/21 90/3270/21 838 380 804 365 7<strong>59</strong> 34480/27 812 368 7<strong>59</strong> 344 715 32490/32 804 365 721 327 676 306lbs./day kg./day 100/38 795 361 710 322 634 288APPROXIMATE ELECTRICCONSUMPTION70/2180/2790/32178318241860183619071965186019201973watts 100/38190019671980APPROXIMATE WATER70/21 472 1.79 405 1.53 356 1.35CONSUMPTION PER 24 HR. 80/27 421 1.<strong>59</strong> 317 1.20 292 1.1090/32 410 1.55 244 0.92 208 0.79gal./day m 3 /day 100/38 405 1.53 235 0.89 174 0.66FREEZING CYCLE TIME70/2180/2790/32212222222426252729min.HARVEST CYCLE TIME100/3870/21234.5273.9313.580/2790/32min. 100/38HEAD PRESSURE3.92.42.070/21 245 17.2 267 18.8 296 20.880/27 262 18.4 296 20.8 324 22.790/32 267 18.8 320 22.5 349 24.5PSIG kg/cm 2 G 100/38 272 19.1 327 23.0 375 26.4SUCTION PRESSURE70/21 33 2.3 36 2.5 40 2.880/27 35 2.5 39 2.7 43 3.090/32 36 2.5 42 3.0 46 3.2PSIG kg/cm 2 G 100/38 37 2.6 43 3.0 50 3.54.14.03.12.53.02.2TOTAL HEAT OF REJECTION FROM CONDENSER14800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]Note: Pressure data is recorded at 5 minutes into freeze cycle. The data not in bold should be used forreference only.We reserve the right to make changes in specifications and design without prior notice.43