2nd Cycle and after with no pump drainIMPORTANTFreeze cycle time is limited to 60 minutes evenif Float Switch does not open.1. Float Switch opens and signals to completefreeze cycle.2. Thermistor reads 48° F.Defrost Timer starts counting.&IMPORTANTWater Valveopening is limited to 6minutes.4. After the first 5 minutes in freeze cycle.Ready to complete freeze cycle when FloatSwitch circuit opens.IMPORTANTBoard never accepts freeze completion signalwithin the first 5 minutes in freeze cycle.3. Defrost Timer stops counting.Defrost cycle is completed and freeze cyclestarts.IMPORTANT1. Board never accepts defrost completionsignal within the first 2 minutes in defrostcycle.2. Defrost cycle time is limited to 20 minuteseven if Defrost Timer does not stop counting.22