26.11.2012 Views

Grout Treatment Facility Borehole Summary Report ... - Hanford Site

Grout Treatment Facility Borehole Summary Report ... - Hanford Site

Grout Treatment Facility Borehole Summary Report ... - Hanford Site

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

WHC-MR-0203<br />

10 WELL DEVELOPMENT<br />

Both of the wells were developed by pumping. A 7j h.p. submersible pump<br />

was placed in each of the wells and pumped until a consistent turbidity value<br />

of less than 5 nephelometric turbidity units (NTU) was reached. All develop-<br />

ment water was contained. A total of 698 gal were pumped out of well<br />

299-E25-37 with a final turbidity of 1.1 NTU. After 1091 gal were pumped out<br />

of well 299-E25-38, the final turbidity was 1.4 NTU. Well development logs<br />

are shown in Appendix D.<br />

Ground-water sampling occurred before development at well 299-E25-38.<br />

This sampling consisted of the full suite of constituents (see Appendix D) to<br />

assist in determining appropriate purge water handling and disposal methods.<br />

in<br />

Two sets of samples were collected during development at each well, one<br />

01 after the wells were purged and one near the end of development. At well<br />

299-E25-37, the first set collected consisted of the full suite of con-<br />

w stituents to assist in determining appropriate purge water handling and<br />

disposal methods. All other samples collected during development only<br />

consisted of samples for metals and total organic halogen. The analyses<br />

results of all samples collected before and during development are shown in<br />

Appendix D. None of the analyses results was above the Interim Primary<br />

Drinking Water Standards (40 CFR 265, Appendix III).<br />

-° The HydroStar® pumps were set at both of the wells on October 12 and 13,<br />

cl^<br />

. 1989. The pump installation reports are shown in Appendix D.<br />

® HydroStar tar is a registered tradename of Instrumentation Northwest,<br />

Incorporated, Redmond, Washington.<br />

9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!