5.3. EXAMPLEGeneral∆p total= ∆p housing+∆p element •viscosity (mm²/s)30 mm²/s∆p housing= to be determined from point 5.1.∆p element= element pressure drop at flow rate Q/n andviscosity 30 mm 2 /s according to point 5.2.n = number of elements according to tableat Point 4, <strong>Filter</strong> specificationsExampleSystem data: <strong>RF</strong>110 with BN3HC element (10 µm)viscosity = 46 mm²/s(ISO VG 46 at 40 °C)Q = 50 l/min⇒ ∆p housing= 0.13 bar (at Q)∆p element= 0.46 bar∆p total= 0.59 barFor ease of calculation, our FSP <strong>Filter</strong> Sizing Programcan be ordered from our website www.hydac.com.6. DIMENSIONS6.1. <strong>RF</strong> 30label with modelcodet4outlethole drilled in the tank coverplate only on version with tankbreather filterd5vent screw or cloggingindicatorinletE 7.116.2/12.04Type b1 b3 d1 d3 1) d5 d6 d7 h1 h2 h3 h4 h5 h6 t1 t2 t4Size 30 71 38 60 G ½ 78 M4 – 86 70 27 8 11 90 14 – 141)threaded connection to ISO 2288