11.07.2015 Views

GE Security Kilsen Fire Systems - Product Catalogue

GE Security Kilsen Fire Systems - Product Catalogue

GE Security Kilsen Fire Systems - Product Catalogue

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

PROGRAMMETHURSDAY 19 APRIL 201209.00-09.30 Registration and coffee09.30-09.40 Opening and welcomeSuzanne Arup Veltzé, Managing Director, DAKOFA (Danish Waste Management)09.40-09.55 Welcome to Copenhagen – a City with focus on climate and sustainabilityAyfer Baykal, Mayor of Copenhagen, Technical and Environmental AdministrationOpening session:Chair: Professor Thomas Højlund Christensen, Technical University of Denmark09.55-10.05 Waste and climate change: ISWA’s call for international actionJeff Cooper, President of ISWA10.05-10.30 Why is waste management important in a climate change perspective?Professor Christos Zerefos, Research Center for Atmospheric Physics and Climatology of theAcademy of Athens, Greece10.30-10.55 EU-Commission Policy: Waste management and resource efficiency – reflections on GHGemissionsMichel Sponar, European Commission10.55-11.20 Waste in a fossil fuel free economyJørgen Henningsen, Former Member of the Danish Commission on Climate Change Policy,Former Principal Advisor of DG Energy and Transport11.20-11.40 CoffeeSession 1: Messages from COP17 in Durban – status and opportunitiesChair: Professor Thomas Højlund Christensen, Technical University of Denmark11.40-12.05 United Nations Framework Convention on Climate Change: Messages from Durban to theinternational waste management sector.Scott J. Stone, Sierra Nevada Corporation12.05-12.30 Scaling up the climate benefits from waste management and recyclingGary Crawford, Veolia Environmental Services


<strong>Fire</strong> PanelsPage 4Conventional fire panel with 2 fire alarm zonesNK702The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK704 has 4 conventional zones.Technical DataSupply Voltage (+10% - 15%)230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteriesCapacity2 x 2.3 AhFuse rating2 AZoneMaximum load94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohmSoundersMaximum load250 mADelaySelectable 0 - 9 minRelay Outputs (excluding sounders)1 A @ 30 VDCExtinguishing Relay OutputsMaximum loadNAFuse ratingNAAuxilliary Output250 mA24 VDC Resetable OutputMaximum Load100 mAReset time3 sEnvironmentWorking temperature-5°C to +40°CRelative humidity (non condencing) 95 %IP ratingIP30Physical CharacteristicsSize (mm)297 (w) x 307 (h) x 105 (d)Weight (without batteries) 3.6 kgOrdering InformationNK702Conventional fire panel with 2 fire alarm zones• Modern, attractive design• Microprocessor-controlled• From 2 up to 16-zones• EN54 compliant with approvals pending• 2 User access levels• 2 Monitored sounder outputs• One-man test capability• Open-collector output for every zone• 24 Volt resetable output• External ‘Class Change’ facility• Alarm output with potential free relay• Common fault output with potential free relay• External watchdog• Active end-of-line support


<strong>Fire</strong> PanelsPage 7Conventional fire panel with 12 fire alarm zonesNK712The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK712 has 12 conventional zones.Technical DataSupply Voltage (+10% - 15%)230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteriesCapacity2 x 7.5 AhFuse rating5 AZoneMaximum load94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohmSoundersMaximum load250 mADelaySelectable 0 - 9 minRelay Outputs (excluding sounders)1 A @ 30 VDCExtinguishing Relay OutputsMaximum loadNAFuse ratingNAAuxilliary Output250 mA24 VDC Resetable OutputMaximum Load100 mAReset time3 sEnvironmentWorking temperature-5°C to +40°CRelative humidity (non condencing) 95 %IP ratingIP30Physical CharacteristicsSize (mm)420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kgOrdering InformationNK712Conventional fire panel with 12 fire alarm zones• Modern, attractive design• Microprocessor-controlled• From 2 up to 16-zones• EN54 compliant with approvals pending• 2 User access levels• 2 Monitored sounder outputs• One-man test capability• Open-collector output for every zone• 24 Volt resetable output• External ‘Class Change’ facility• Alarm output with potential free relay• Common fault output with potential free relay• External watchdog• Active end-of-line support


<strong>Fire</strong> PanelsPage 8Conventional fire panel with 16 fire alarm zonesNK716The NK700 series of conventional fire alarm and extinguishing control panelsis the ideal solution for small to medium-sized installations. Very powerfuland cost-effective, they are extremely simple to install and use due to theirergonomic, advanced design. The NK716 has 16 conventional zones.Technical DataSupply Voltage (+10% - 15%)230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteriesCapacity2 x 7.5 AhFuse rating5 AZoneMaximum load94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohmSoundersMaximum load250 mADelaySelectable 0 - 9 minRelay Outputs (excluding sounders)1 A @ 30 VDCExtinguishing Relay OutputsMaximum loadNAFuse ratingNAAuxilliary Output250 mA24 VDC Resetable OutputMaximum Load100 mAReset time3 sEnvironmentWorking temperature-5°C to +40°CRelative humidity (non condencing) 95 %IP ratingIP30Physical CharacteristicsSize (mm)420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kgOrdering InformationNK716Conventional fire panel with 16 fire alarm zones• Modern, attractive design• Microprocessor-controlled• From 2 up to 16-zones• EN54 compliant with approvals pending• 2 User access levels• 2 Monitored sounder outputs• One-man test capability• Open-collector output for every zone• 24 Volt resetable output• External ‘Class Change’ facility• Alarm output with potential free relay• Common fault output with potential free relay• External watchdog• Active end-of-line support


Extinguishing PanelsPage 9Conventional extinguishing control panel with 3 zonesNK703The NK703 conventional fire alarm and extinguishing control panels is theideal solution for small to medium-sized installations. Very powerful and costeffective,they are extremely simple to install and use due to their ergonomic,advanced design. It has 1 double-knock extinguising area consisting of twofire zones, and 1 free fire detection zone.Technical DataSupply Voltage (+10% - 15%)230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteriesCapacity2 x 7 AhFuse rating2 AZoneMaximum load94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohmSoundersMaximum load250 mADelaySelectable 0 - 9 minRelay Outputs (excluding sounders)1 A @ 30 VDCExtinguishing Relay OutputsMaximum load250 mAFuse rating0.3 AAuxilliary Output250 mA24 VDC Resetable OutputMaximum Load100 mAReset time3 sEnvironmentWorking temperature-5°C to +40°CRelative humidity (non condencing) 95 %IP ratingIP30Physical CharacteristicsSize (mm)420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kgOrdering InformationNK703Conventional extinguishing control panel with 3 zones• Modern, attractive design• Microprocessor controlled• 3 zone (1 ext. area) and 6 zone (2 ext. areas) available• Automatic extinguishing agent release control• EN54 compliant• 2 Access levels• Supervised general sounder output• Supervised extinguishing inputs and outputs• One-man test capability• 24 Volt resetable output• External ‘class change’ facility• Alarm output with potential free relay• General fault output with potential free relay• External watchdog


Extinguishing PanelsPage 10Conventional extinguishing control panel with 5 zonesNK706The NK706 conventional fire alarm and extinguishing control panels is theideal solution for small to medium-sized installations. Very powerful and costeffective,they are extremely simple to install and use due to their ergonomic,advanced design. It has 2 double-knock extinguising areas consisting of twofire zones each, and 2 free fire detection zones.Technical DataSupply Voltage (+10% - 15%)230 VAC @ 50 Hz / 110 VAC @ 60 HzBatteriesCapacity2 x 7 AhFuse rating2 AZoneMaximum load94 mAMax. number of detectors per zone 20Maximum zone resistance 44 ohmSoundersMaximum load250 mADelaySelectable 0 - 9 minRelay Outputs (excluding sounders)1 A @ 30 VDCExtinguishing Relay OutputsMaximum load250 mAFuse rating0.3 AAuxilliary Output250 mA24 VDC Resetable OutputMaximum Load100 mAReset time3 sEnvironmentWorking temperature-5°C to +40°CRelative humidity (non condencing) 95 %IP ratingIP30Physical CharacteristicsSize (mm)420 (w) x 335 (h) x 110 (d)Weight (without batteries) 6.2 kgOrdering InformationNK706Conventional extinguishing control panel with 5 zones• Modern, attractive design• Microprocessor controlled• 3 zone (1 ext. area) and 6 zone (2 ext. areas) available• Automatic extinguishing agent release control• EN54 compliant• 2 Access levels• Supervised general sounder output• Supervised extinguishing inputs and outputs• One-man test capability• 24 Volt resetable output• External ‘class change’ facility• Alarm output with potential free relay• General fault output with potential free relay• External watchdog


Expansion ModulesPage 11Relay module, 4 potential free relays for NK700/Fx400 fire panelsRB404The RB404 relay expander module has voltage-free 4 relays. The unit allowsfor a relay for each detection zone or for programming the activation ofdifferent relays depending on the status of one or more zones. It is used on the<strong>GE</strong>-Interlogix NK700/FP400 conventional fire panel range.Technical DataRelay RatingVoltageCurrentDelay setting230 VDC2 A0 to 9 minutesOrdering InformationRB404Relay module, 4 potential free relays for NK700/Fx400 fire panels• 4 Potential free relays• Up to 4 modules may be housed inside the fire panel cabinet• Programable with basic boolen functions• Power supplied from fire panel bus• Output delay setting per relayRelay module, 4 supervised relays for NK700/Fx400 fire panelsSB404The SB404 module has 4 relays that provide 4 of 24 VDC supervised outputs.These may be configured to power sounders or as standard 24 VDC supervisedoutputs for other devices.Technical DataAux. SupplyDelay Setting24 VDC0 to 9 minutesOrdering InformationSB404Relay module, 4 supervised relays for NK700/Fx400 fire panels• 4 Supervised relays• Up to 4 modules may be housed inside the fire panel cabinet• Programable with basic boolen functions• Output delay setting per relay• Configurable for sounder control or as supervised outputs


<strong>Fire</strong> PanelsPage 12Analogue addressable fire detection panel - 1 loopKSA701/1The KSA701 analogue addressable fire alarm control panel is the idealsolution for small to medium-sized installations. Very powerful and costeffective,it is extremely simple to install and use due to its ergonomic,advanced design. The panel is supplied in an elegant, high-quality,conveniently sized, heavy-duty enclosure. The cabinet allows for enough spacefor the batteries for the system to be housed inside the cabinet. The KSA701 isfully compatible with the <strong>Kilsen</strong> 700A series detectors and KAL400 seriesaccessories.Technical DataSupply Voltage 110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)Current Consumption175 mA Quiescent / 241 mA in alarm with nodevices connectedBatteriesCapacity2 x 12 V - 7 AH (SLA type)Fuse Rating3 ACharger Rating350 mA @ 27.6 VDC @ 20 °C (Temperaturecompensated -3 V / °C)Loop characteristics per loopCapacity125 addresses per loopMaximum Load400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of1.5 mm2 diameter cableSounders (reverse polarity supervision)Maximum Load 250 mA each (2 Sounder outputs available) / 18VDC to 24 VDCDelays10 seconds to 600 seconds, software adjustable in10 second intervalsRelay Outputs (potential free)1 A @ 30 VDC24 V Auxiliary OutputMaximum Load250 mA @ 18 VDC to 28 VDCEnvironmentWorking Temperature -5°C to +40 °CRelative Humidity0-95% non-condensingIP RatingIP30Physical CharacteristicsSize420 mm (w) x 335 (h) x 110 (d)Weight6.2 kg without batteries / 10.7 kg with 2 x 7 Ahbatteries• 4 x 40 characters LCD display• 20 Display zones• EN54 compliant with approvals pending• 4 User access levels• 2 Monitored sounder outputs• 2 Programmable voltage free relays• 24 Volt auxiliary output• I/O programming capabilities with Boolean functions• Day/night sensitivity settings• Coincidence within zones• Upload/download and graphic PC software• Panel networking• Installation test capabilityOrdering InformationKSA701


<strong>Fire</strong> PanelsPage 15Analogue addressable fire panel with printer (expandable to 5 loops)KSA705PThe KSA700 Series analogue addressable fire panels offer leading-edgetechnology for the control of analogue addressable fire detection devices.Their unique user-friendly programming facilitate the ideal controlenvironment for either simple or complex fire systems. The KSA705P offers anadditional internal printer facility.Technical DataSupply Voltage 230 VAC @ 50 Hz (+10% -15%)Current Consumption (with no devices connected) 175 mA Quiescent / 241 mA in alarmBatteriesCapacity2 x 12 V - 6 AH (SLA type)Fuse Rating4 ACharger Rating (Temperature compensated -3 V / °C) 350 mA @ 27.6 VDC @ 20°CLoop characteristics per loopCapacity250 addressesMaximum Load400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of1.5 mm2 diameter cableSounders (reverse polarity supervision)Maximum Load 250 mA each (2 Sounder outputs available) / 18VDC to 24 VDCDelays (software adjustable in 10 second intervals) 10 to 600 secondsRelay Outputs (potential free)1 A @ 30 VDC24 V Auxiliary OutputMaximum Load800 mA @ 18 VDC to 28 VDCEnvironmentWorking Temperature -5°C to +40 °CRelative Humidity (non-condensing) 0-95%IP RatingIP41Physical CharacteristicsSize480 mm (w) x 455 (h) x 140 (d)Weight13.6 kg without batteries / 21.6 kg with 2 x 7 Ahbatteries• 4-line, 40-character LCD display• Panel networking capability• Graphic monitoring software• Windows based up/download programming software• Remote programming and maintenance via modem and TCP/IP• Repeater facilities• Powerful auto-configuration functions• Simple program options with on-screen menu selection• EN54 approvals pendingOrdering InformationKSA705PAnalogue addressable fire panel with printer (expandable to 5 loops)


Expansion ModulesPage 17GSM Modem for <strong>Kilsen</strong> <strong>Fire</strong> PanelsMODGSMThe MODGSM modem may be used in KSA701/FP1500, KSA702 and KSA705fire panel from <strong>GE</strong>-Interlogix. It is ideal for use as a standard modem formaking and receiving calls from and to the fire panel, but may also be usedfor GSM messaging.Technical DataGSM Band900/1800 MHzServicesData, SMS, Voice and FaxAT Commands GSM 07.07 and 07.05Output Power (max)GSM9002 WGSM18001 WInput Voltage5 to 32 VCurrent @ 5VAvarage330 mAPeak1.8 ASIM Interface3V / 5VDimensions (h x w x d)98 x 54 x 25 mmWeight130 gEnvironmental TemperatureStorage - 25 °C to + 70 °COperating - 20 °C to + 55 °COrdering InformationMODGSMGSM Modem for <strong>Kilsen</strong> <strong>Fire</strong> Panels• Dual-Band 90/1800 MHz• Data and SMS services• Remote control by AT commands• Wide input voltage range


Expansion ModulesPage 18Loop driver module for KSA702/705 control panelsKAL701The KAL701 1 loop expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module consist of a simpleplug in card and requires no additional settings or connections for fullfunctionality. The KAL701 has loop isolators supplied on both drivers andalows full class-A loop functionality with up to 250 device addresses.Technical DataNumber of loops 1Loop characteristicsCapacity250 addressesMaximum Load400 mA / 26 VDC to 32 VDCMaximum Electrical Characteristics 44 Ohm / 500 nFMaximum Loop Length2 kmOrdering InformationKAL701Loop driver module for KSA702/705 control panels• Expands the loop capabailities of the KSA702 and KSA705• Allows for the connection of an additional 250 devices per unit• Two isolated drivers support full class-A operation• No hardware configuration requiredRS232 communications module for KSA702/5 control panelsKAL732The KAL732 RS232 expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module adds an additionalindustry standard RS232 communication port to the panel. This port could beused for communications with a PC or for connections to a printer or modem.Technical DataNumber of ports 1Communications mediumRS232Technical specificationsMaximum cable length 15 mCommunication speed9600 baudCable3 core with screenOrdering InformationKAL732RS232 communications module for KSA702/5 control panels• Industry standard RS232 communications• No hardware configuration required


Expansion ModulesPage 19RS485 communications module for KSA702/5 control panelsKAL785The KAL785 RS485 expander allows for an easy upgrade to the KSA702 andKSA705 analalogue addressable fire panels. Each module adds an additionalindustry standard RS485 communication port to the panel. This port could beused for communications with other network nodes in the fire panel network.Technical DataNumber of ports 1Communications mediumRS485Technical specificationsMaximum cable length 1200 mCommunication speed9600 baudCableCAT5 - twisted with screenTermination resistance 150 OhmOrdering InformationKAL785RS485 communications module for KSA702/5 control panels• Industry standard RS485 communications• No hardware configuration requiredRS485 expansion kit for KSA701/FP1500 fire panelsNC785The NC785 RS485 expander allows for an easy upgrade to the KSA701/FP1500series analalogue addressable fire panels. Each module adds an additionalindustry standard RS485 communication port to the panel. This port could beused for communications with other network nodes in the fire panel network.Technical DataNumber of ports 1Communications mediumRS485Technical specificationsMaximum cable length 1200 mCommunication speed9600 baudCableCAT5 - twisted with screenTermination resistance 150 OhmOrdering InformationNC785RS485 expansion kit for KSA701/FP1500 fire panels• Industry standard RS485 communications• No hardware configuration required


CO DetectionPage 20CO detection control panel - 1 ZoneCO detection control panel - 2 ZonesCO detection control panel - 3 ZonesCO detection control panel - 4 ZonesCO detection control panel - 5 ZonesKM260/1-INGKM260/2-INGKM260/3-INGKM260/4-INGKM260/5-INGThe KM-Series CO detection system is designed for applications such asvehicle parking areas where concentrations of CO may accumulate. The rangeis compliant with the UNE23.300/84 standard. The KM260/1 is a 1 to 5 zonescontrol units, using KM170 detectors.Technical DataPower SupplyMains Supply230 VAC ±10% 50 HzPower Consumption95 W (max)Zone ConfigurationZone Input Voltage10-20 VDC/VACSensitiviy0-300 ppmCable Requirement3 core 1.5 mm²Cable Length (max)350 mNo. of Detectors (max) 15No. of Zones (max) 5MechanicalHousing (w x h x d)275 x 335 x 130 mmWeight6 kgOrdering InformationKM260/1-INGKM260/2-INGKM260/3-INGKM260/4-INGKM260/5-INGCO detection control panel - 1 ZoneCO detection control panel - 2 ZonesCO detection control panel - 3 ZonesCO detection control panel - 4 ZonesCO detection control panel - 5 Zones• Designed according to norm 23300/84• Miner CDM8001 and CDM8002 standard password• LGAI 154.909 and 96013132 standard certification• Easy to use• Low current consumption• Direct reading of measured levels• Easy installation• Extraction relays and alarm outputs per area• From 1 to 5 areas• 3-wire system• Modular design• Up to 15 detectors per zone• 10 seconds response time• Elegant design• Supervision of all zone lines• Available in various languages


CO DetectionPage 21CO detection expansion moduleKM260-INGThe KM260 is an expansion module for the KM260-Series CO panels from <strong>GE</strong>-Interlogix. It allows for an additional monitoring zone to be added to thecontrol panel, each module allowing for an additional 15 sensors to beconnected.Technical DataPower SupplyMains Supply230 VAC ±10% 50 HzPower Consumption95 W (max)Zone ConfigurationZone Input Voltage10-20 VDC/VACSensitiviy0-300 ppmCable Requirement3 core 1.5 mm²Cable Length (max)350 mNo. of Detectors (max) 15No. of Zones (max) 1Ordering InformationKM260-INGCO detection expansion module• Designed according to norm 23300/84• Miner CDM8001 and CDM8002 standard password• LGAI 154.909 and 96013132 standard certification• Easy to use• Low current consumption• Direct reading of measured levels• Easy installation• Extraction relays and alarm outputs per area• 3-wire system• Up to 15 detectors per zone• 10 seconds response time• Supervision of zone line• Available in various languages


CO DetectorsPage 22CO detector with base and mounting supplementKM170The KM170 detector is specifically designed to react to the presence of carbonmonoxide. The design complies with the requirements of the UNE 23-300standard.Technical DataSensor TypeTGS SemicondictorUseful Life4 yearsElectrical CharacteristicsSupply Voltage10 to 20 VDCQuiescent Current35 mAReaction Time10 sEnvironmentalOperating Temperature 0 to 40 °CProtection IndexIP205MechanicalSize (h x Ø)81 x 109 mmWeight115 gMaterial and ColourABS WhiteInstallationNumber of detectors per zone 15Covarage 300 m²Ordering InformationKM170CO detector with base and mounting supplement• Complies with the requirements of the UNE23-300 standard• Microprocessor based• Resolution of up to 5 ppm• Response time of 10 s• Low current consumption• Local status indication of:• Normal operation• 50 ppm detected• Fault• Useful life of up to 4 years


DetectorsPage 23Aspiration Smoke DetectorASD20GeneralThe ASD20 Aspiration Smoke Detector consists of an analysis chamber withone or two smoke detectors, which can be of conventional or analoguetechnology, ionisation or optical. The smoke reaches the analysis chamberthrough the installation pipes after having been sucked in by a turbine insidethe ASD20 system. An electronic circuit controls said turbine and the air flow,giving off a fault signal if the pipes are broken or if the air intake isobstructed. It has two voltagefree relays for local manoeuvres, one perdetector, and a third system fault relay. When analogical smoke detectorsfrom the 700A series are used, it is possible to adjust their sensitivity levelsfrom the fire control unit.Technical DataPower supply voltage24 VConsumption on standby250 mAConsumption 1st alarm280 mAConsumption 2nd alarm320 mAFault consumption220 mAWorking temperature-10 to +60°CStorage temperature-10 to +70°CRelative humidity


Power SuppliesPage 24Power supply unit with battery charger 0.8AFC251The FC250 Series is suitable for devices requiring an uninterrupted, regulated24 VDC power supply. The units include a battery charger outlet and anoptional reset facility. The supply is mounted inside a metal casing whichincludes space for two 12 V sealed lead acid batteries.Technical DataMechanicalDimensions (w x h x d) 215 x 260 x 75 mmWeight (without batteries) 2.5 kgElectricalOperating Voltage 230 VAC 50Hz ±10%Output Voltage24 VDCBatteries2 x 12 V 2.1 AhEnvironmentalOperating Temperature -10 °C to 40 °CStorage Temperature -10 °C to 40 °CRelative Humidity (Non Condencing) 95% maxOrdering InformationFC251 Power supply unit with battery charger 0.8A• Fuse protection on both the input and the outputs• Low maintenance• Batteries may be housed internally• Various supply ratings availablePower supply unit with battery chargerFC252The FC250 Series is suitable for devices requiring an uninterrupted, regulated24 VDC power supply. The units include a battery charger outlet and anoptional reset facility. The supply is mounted inside a metal casing whichincludes space for two 12 V sealed lead acid batteries.Technical DataMechanicalDimensions (w x h x d) 290 x 360 x 110 mmWeight (without batteries) 6.26 kgElectricalOperating Voltage 230 VAC 50Hz ±10%Output Voltage27.6 VDCBatteries2 x 12 V 6 AhEnvironmentalOperating Temperature -10 °C to 40 °CStorageTemperature -10 °C to 40 °CRelative Humidity (Non Condencing) 95% maxOrdering InformationFC252 Power supply unit with battery charger 1.5AFC253Power supply unit with battery charger 3A• Fuse protection on both the input and the outputs• Low maintenance• Batteries may be housed internally• Various supply ratings available


<strong>Fire</strong> indicatorsPage 25Illuminated warning sign (No text) 24VDCKR24BThe KR24 is specifically designed as an evacuation warning sign for gasextinguising areas. The KR24B has no text on the backlit display, and text maytherefor be added as required for the application. Units supplied with text invarious languages are also availble.Technical DataElectrical SpecificationsSupply Voltage18 to 27 VDCActivation Voltage18 to 27 VDCCurrent Consumption600 mASwitching PolarityNAIndicators24 V 3 WEnvironmental SpecificationsWorking Temperature -10 to 75 °CPhysical SpecificationsNumber of zonesNABuzzer output80 dBHousing ColourGreyDisplay ColourRedWeight700 gOrdering InformationKR24BIlluminated warning sign (No text) 24VDC• - Low current consumption• - Large angle of view• - Optical and acoustic indications selectable• - Modern and elegant design


<strong>Fire</strong> DetectorsPage 26Ionisation detector, conventionalKL700Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the <strong>Kilsen</strong> NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.Technical DataOperating voltage18 to 28 VDCCurrent consumptionQuiescent at 24 VDC 30 µAAlarm at 24 VDC< 100 mARadio-active source Americium 241Average activity0.33 +/-0.04µCi (12.1 +/- 1.5 kBq)Remote alarm output< 100 mAHeat specificationOperating temperature -10 to +60 °CStorage temperature -10 to +70 °CHumidity (non-condensing) 0 - 95%IP ratingIP205Number of detectors per zone 20Recommended protection resistor300 ohmDimensions (h x Ø)Head45 mm x 99 mmBase24 mm x 103 mmApprovals*VdSLPCB* Check current status with local officeOrdering InformationKL700Ionisation detector, conventional• Full line consisting of Optical, Ionisation and Heat detectors• An ultra-fine grid prevents the ingress of dust and insects insmoke detectors• Attractive, low-profile design• EN54, LPCB and VdS certification marks (*)• Innovative base compensates for uneven surfaces• Field exchangable optical chamber for ease of maintenance


<strong>Fire</strong> DetectorsPage 27Temperature detector (fixed and rate-of-rise), conventionalKL710Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the <strong>Kilsen</strong> NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.Technical DataOperating voltage18 to 28 VDCCurrent consumptionQuiescent at 24 VDC 70 µAAlarm at 24 VDC< 100 mARadio-active sourceAverage activityRemote alarm output< 100 mAHeat specificationMax. & ROR to EN54p5Operating temperature -10 to +70 °CStorage temperature -10 to +80 °CHumidity (non-condensing) 0 - 95%IP ratingIP205Number of detectors per zone 20Recommended protection resistor300 ohmDimensions (h x Ø)Head45 mm x 99 mmBase24 mm x 103 mmApprovals*VdSLPCB* Check current status with local officeOrdering InformationKL710Temperature detector (fixed and rate-of-rise), conventional• Full line consisting of Optical, Ionisation and Heat detectors• An ultra-fine grid prevents the ingress of dust and insects insmoke detectors• Attractive, low-profile design• EN54, LPCB and VdS certification marks (*)• Innovative base compensates for uneven surfaces• Field exchangable optical chamber for ease of maintenance


<strong>Fire</strong> DetectorsPage 28Optical detector, conventional (with field exchangeable optical block)KL731Of outstanding performance, efficiency and durability, the 700 series firedetectors are the ideal solution for conventional installations. They aredesigned specifically for use with the <strong>Kilsen</strong> NKB600, NK600 and NK700 seriesconventional fire panels, but are also compatible with most 3rd party industrystandard conventional control panels.Technical DataOperating voltage9 to 28 VDCCurrent consumptionQuiescent at 24 VDC 85 µAAlarm at 24 VDC< 100 mARadio-active sourceAverage activityRemote alarm output< 100 mAHeat specificationOperating temperature -10 to +70 °CStorage temperature -10 to +70 °CHumidity (non-condensing) 0 - 95%IP ratingIP42Number of detectors per zone 20Recommended protection resistor300 ohmDimensions (h x Ø)Head45 mm x 99 mmBase24 mm x 103 mmApprovals*EN54** Check current status with local officeOrdering InformationKL731Optical detector, conventional (with field exchangeable optical block)• Full line consisting of Optical, Ionisation and Heat detectors• An ultra-fine grid prevents the ingress of dust and insects insmoke detectors• Attractive, low-profile design• EN54, LPCB and VdS certification marks (*)• Innovative base compensates for uneven surfaces• Field exchangable optical chamber for ease of maintenance


Test and Service EquipmentPage 29KL731/DP331I Calibration ToolKCT731The KCT731 is a calibration tool to recalibrate the KL731/DP331I conventionaldetectors after replacement of the field exchangeable optical block.Technical DataSupply2 x 9 V batteriesOrdering InformationKCT731KL731/DP331I Calibration Tool• Easy to use• Simple “go/no-go” function• Battery operated


<strong>Fire</strong> DetectorsPage 30Analogue addressable ionisation sensorKL700AThe KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.Technical DataOperating voltage22 - 38 VDCCurrent consumptionQuiescent @ 38 VDC 200 µAIn Alarmless than 11 mAAlarm indication (Dual LED)White OFF - Red ONRemote Alarm OutputAvailableEnvironmentStorage Temperature -10 °C to +70 °COperating Temperature -10 °C to +60 °CHumidity (non-condensing) 0-95%IP ratingIP205Radioactive Source 0.33 ± 0.04 µCi Am 241Dimensions (h x Ø)45 mm x 99 mmOrdering InformationKL700AAnalogue addressable ionisation sensor• Remote signalling capabilities• Easy soft addressing (1-125)• SMD technology• Reliable communication protocol• Full diagnostic self testing• Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)• Full range of supporting I/O units and accessories• EN54 Approved


<strong>Fire</strong> DetectorsPage 31Analogue addressable temperature sensorKL710AThe KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.Technical DataOperating voltage22 - 38 VDCCurrent consumptionQuiescent @ 38 VDC 250 µAIn Alarmless than 11 mAAlarm indication (Dual LED)White OFF - Red ONRemote Alarm OutputAvailableEnvironmentStorage Temperature -10 °C to +80 °COperating Temperature -10 °C to +70 °CHumidity (non-condensing) 0-95%IP ratingIP205Radioactive SourceNADimensions (h x Ø)45 mm x 99 mmOrdering InformationKL710AAnalogue addressable temperature sensor• Remote signalling capabilities• Fixed and Rate-of-Rise heat detectors• Easy soft addressing (1-125)• SMD technology• Reliable communication protocol• Full diagnostic self testing• Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)• Full range of supporting I/O units and accessories• EN54 Approved


<strong>Fire</strong> DetectorsPage 32Analogue addressable optical sensor (with field exchangeable chamber)KL731AThe KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.Technical DataOperating voltage22 - 38 VDCCurrent consumptionQuiescent @ 38 VDC 350 µAIn Alarmless than 11 mAAlarm indication (Dual LED)RedRemote Alarm OutputAvailableEnvironmentStorage Temperature -10 °C to +70 °COperating Temperature -10 °C to +60 °CHumidity (non-condensing) 0-95%IP ratingIP205Radioactive SourceNADimensions (h x Ø)45 mm x 99 mmOrdering InformationKL731AAnalogue addressable optical sensor (with field exchangeable chamber)• Remote signalling capabilities• Field exchangeable optical chamber• Easy soft addressing (1-125)• SMD technology• Reliable communication protocol• Full diagnostic self testing• Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)• Full range of supporting I/O units and accessories• EN54 Approved• Black Colour


<strong>Fire</strong> DetectorsPage 33Analogue addressable dual (optical and thermal) sensorKL735AThe KL700A Series uses a microprocessor for measurement andcommunication. An enhanced protocol ensures the overall integrity and errorfree operation of the fire system, without compromising speed. All sensors arecompatible with a standard base that makes them easily interchangeable andthat supports the connection of a remote indicator.Technical DataOperating voltage22 - 38 VDCCurrent consumptionQuiescent @ 38 VDC 350 µAIn Alarmless than 5 mAAlarm indication (Dual LED)RedRemote Alarm OutputAvailableEnvironmentStorage Temperature -10 °C to +70 °COperating Temperature -10 °C to +70 °CHumidity (non-condensing) 0-95%IP ratingIP42Radioactive SourceNADimensions (h x Ø)51 mm x 99 mmOrdering InformationKL735AAnalogue addressable dual (optical and thermal) sensor• Remote signalling capabilities• Fixed and Rate-of-Rise heat detectors• Easy soft addressing (1-125)• SMD technology• Reliable communication protocol• Full diagnostic self testing• Full range: Ionisation, Optical and Heat and Duel sensors(optical/heat)• Full range of supporting I/O units and accessories• EN54 Approved


AccessoriesPage 34<strong>Fire</strong> sensor programmerPG700The PG700 is a handheld device programmer and tester for theKL700A/Dx1500 series detectors. It is battery operated and allows the installerto perform installation tasks (such as device addressing) and maintenancetasks (such as device clibration) in the field without external assistance.Technical DataSupply2 x 9 V batteriesOrdering InformationPG700<strong>Fire</strong> sensor programmer• Easy to use• Battery operated• 4 User selectable programs• - Device analogue value• - Change Device Address• - Sequential device addressing• - KL731A Calibration


BasesPage 35<strong>Fire</strong> Detector base for KL300 series devicesKZ300The KZ300 base is designed to be used with the KL300 series detectors from<strong>Kilsen</strong>.Technical DataDimensionsDiameterHeight107 mm22 mmOrdering InformationKZ300<strong>Fire</strong> Detector base for KL300 series devices• Polarity sensitive• Remote indicator contact available.Surface mount supplement for KL300 detectorsS300The S300 is a base accessory designed for use with the KZ300 detector base.It allows for a surface mount conduit and cable to enter the base from theside. The KZ300 base fits on top of this accessory.Technical DataDimensionsDiameterHeight107 mm25 mmOrdering InformationS300Surface mount supplement for KL300 detectors• Surface mount accessory for KZ300


BasesPage 36Surface mount accessory for KZ700/DB304 and KZ700 series basesS700The S700 is a base accessory designed for use with the KZ700 series detectorbases. It allows for a surface mount conduit and cable to enter the base fromthe side. The KZ700 series base fits on top of this accessory.Technical DataDimensionsDiameterHeight95 mm30 mmOrdering InformationS700Surface mount accessory for KZ700/DB304 and KZ700 series bases• Surface mount accessory for KZ700 series basesConventional fire detector base with diodeKZ705DThe KZ705D is a 5 contact universal detector base for use with theKL700/Dx300 series detectors from <strong>GE</strong>-Interlogix. In addition to the normalbase and remote indication connectors, the KZ705D also has an additionalearth terminal connector to allow for easy terminations of a possible cablescreen. The built in diode is specifically targeted at systems using active endof-linedevices.Technical DataDimensions (Ø x h)100 x 29 mmOperating VoltageCurrent ConsumptionIsolation CurrentIsolation ResistanceSounder FrequencySound Output@ 3 mA@ 5 mAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)Ordering InformationKZ705DConventional fire detector base with diode• Polarity sensitive• Universal base for conventional detectors• Additional earth terminal available• Remote indicator contact available• Built in diode for active end-of-line systems


BasesPage 37Universal fire detector base (for KL700 and KL700A series detectors)KZ700The KZ700 is a 4 contact universal detecor base for use with the KL700 andKL700A series detectors from <strong>Kilsen</strong>. It has the ability to compensate foruneven mounting surfaces.Technical DataDimensionsDiameterHeight104 mm24 mmOrdering InformationKZ700Universal fire detector base (for KL700 and KL700A series detectors)• Polarity sensitive• Universal base fits conventional and analogue detectors• Compensates for uneven surfaces• Remote indicator contact available• EN54 approved• Black ColourUniversal fire detector base with earth connectionKZ705The KZ705 is a 5 contact universal detector base for use with theKL700/Dx300 and KL700A/Dx1500 series detectors from <strong>GE</strong>-Interlogix. Inaddition to the normal base and remote indication connectors, the KZ705 alsohas an additional earth terminal connector to allow for easy terminations of apossible cable screen.Technical DataDimensions (Ø x h)100 x 29 mmOperating VoltageCurrent ConsumptionIsolation CurrentIsolation ResistanceSounder FrequencySound Output@ 3 mA@ 5 mAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)Ordering InformationKZ705Universal fire detector base with earth connection• Polarity sensitive• Universal base fits conventional and analogue detectors• Additional earth terminal available• Remote indicator contact available


BasesPage 38Active end-of-line device for use with FP400/KL700 fire panelsEOL-ACTThe EOL-ACT is designed for use with the NK700/FP400 fire panels from <strong>GE</strong>-Interlogix. It is an active end-of-line device to allow the monitoring of aconventional zone through a diode base (such as the KZ705D).Ordering InformationEOL-ACTActive end-of-line device for use with FP400/KL700 fire panels• Small• Easy to install


BasesPage 39Conventional fire detector base with relayKZ705RThe KZ705R is a 5 contact detector base for use with the KL731/DP331Idetectors from <strong>GE</strong>-Interlogix. In addition to the normal base and remoteindication connectors, the KZ705R also has an additional earth terminalconnector to allow for easy terminations of a possible cable screen. A built in12 V relay makes it ideal for use on low voltage intrusion systems.Technical DataDimensions (Ø x h)100 x 29 mmOperating Voltage 12 V ± 10%Current Consumption 12 µAIsolation CurrentIsolation ResistanceSounder FrequencySound Output@ 3 mA@ 5 mAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)Ordering InformationKZ705RConventional fire detector base with relay• Polarity sensitive• 12 V relay for 4 wire systems• Additional earth terminal available• Remote indicator contact availableAnalogue fire detector base with isolatorKZ705IThe KZ705I is a detector base with built in isolator for use with theKL700A/Dx1500 series detectors from <strong>GE</strong>-Interlogix. The isolator protects theloop from short circuit conditions. A LED on the side of the base indicates thestatus of the isolator.Technical DataDimensions (Ø x h)100 x 29 mmOperating Voltage17 - 34 VCurrent Consumption 50 µAIsolation Current6 mAIsolation Resistance140 MOhmSounder FrequencySound Output@ 3 mA@ 5 mAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)Ordering InformationKZ705IAnalogue fire detector base with isolator• Polarity sensitive• Universal base for analogue detectors• Additional earth terminal available• Remote indicator contact available• Built in isolator


BasesPage 40Analogue fire detector base with sounderKZ705ASThe KZ705AS is a detector base with built in analogue addressable sounderfor use with the KL700A/Dx1500 series detectors from <strong>GE</strong>-Interlogix. Thesounder has its own address on the fire panel loop and works independent ofthe detector. It is fully controlled from the fire panel.Technical DataDimensions (Ø x h)120 x 58 mmOperating Voltage22 - 38 VCurrent Consumption300 µA QuiescentIsolation CurrentIsolation ResistanceSounder Frequency1 KHzSound Output@ 3 mA85 dBA@ 5 mA95 dBAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)IP RatingIP21cOrdering InformationKZ705ASAnalogue fire detector base with sounder• Polarity sensitive• Universal base for analogue detectors• Additional earth terminal available• Remote indicator contact available• Built in sounder• Up to 90 dBA sound output• Low current consumption


BasesPage 41Analogue fire detector base with isolator and sounderKZ705IASThe KZ705IAS is a detector base with built in analogue addressable sounderand isolator for use with the KL700A/Dx1500 series detectors from <strong>GE</strong>-Interlogix. The sounder has its own address on the fire panel loop and worksindependent of the detector. It is fully controlled from the fire panel. Theisolator protects the loop from short circuit conditions.Technical DataDimensions (Ø x h)120 x 58 mmOperating Voltage22 - 38 VCurrent Consumption350 µA QuiescentIsolation Current6 mAIsolation Resistance140 MOhmSounder Frequency1 KHzSound Output@ 3 mA85 dBA@ 5 mA95 dBAEnvironmental CharacteristicsOperating Temperature -10 to 70 °CStorage Temperature -10 to 70 °CRelative Humidity (max) 95 % (non-cond.)IP RatingIP21cOrdering InformationKZ705IASAnalogue fire detector base with isolator and sounder• Polarity sensitive• Universal base for analogue detectors• Additional earth terminal available• Remote indicator contact available• Built in sounder• Up to 90 dBA sound output• Low current consumption• Built in isolator


I/O ModulesPage 42Conventional Zone Monitor Unit - 1 ZoneKAL410Allows the connection of one conventional zone to the analogue fire systemloop. This zone is constantly monitored. Up to 20 conventional devices may beconnected to this zone.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 90 µAQuiescent @ 35 V 105 µAAlarm< 3 mAAux. Supply (24V DC) Quiescent 200 µA + equipAux. Supply (24V DC) Alarm < 85 mAEnd-of-line resistor4.7 kOhmRelay contact ratingNAEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)117 x 80 x 44 mmOrdering InformationKAL410Conventional Zone Monitor Unit - 1 Zone• Easy numeric addressing• Continuous supervision of the conventional zones• Surface mount• Local alarm indication• Externally powered• Aesthetically pleasing• Part of a family of I/O modules consisting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 43Conventional Zone Monitor Unit - 4 ZonesKAL414/4Allows the connection of four conventional zones to the analogue fire systemloop. These zones are constantly monitored. Up to 20 conventional devicesmay be connected to any zone.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm< 5 mAAux. Supply (24V DC) Quiescent 200 µA + equipAux. Supply (24V DC) Alarm < 360 mAEnd-of-line resistor4.7 kOhmRelay contact ratingNAEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)163 x 107 x 36 mmOrdering InformationKAL414/4Conventional Zone Monitor Unit - 4 Zones• Easy numeric addressing• Continuous supervision of the conventional zones• Surface mount• Local alarm indication• Externally powered• Aesthetically pleasing• Part of a family of I/O modules consisting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 44Extinguishing Control ModuleKAL426The 400 Series modules consists of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from <strong>GE</strong>Interlogix. The KAL426 allows for the connection and control of oneextinguishing area to the addressable fire panel loop.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 210 µAAlarm< 10 mAAux. Supply (24V DC) Quiescent 120 mAAux. Supply (24V DC) Alarm < 1 AEnd-of-line resistor4.7 kOhmRelay contact rating2½ AEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)163 x 107 x 36 mmOrdering InformationKAL426Extinguishing Control ModulePK10TDExtinguishing RELEASE MCP with protective cover (Spanish Version)PK10TPExtinguishing INHIBIT MCP with protective cover (Spanish Version)KR24Illuminated extinguishing waring sign (Spanish version) 24VDCSK07Low consumption multi-tone alarm siren• Aesthetically pleasing• Easy numeric addressing• Externally powered• Normally Open / Normally Closed operation for I/O• Surface mount• Wide range of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 45Relay Module - 1 RelayKAL430Provides for one potential free relay output for the fire system loop. Each relayallows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. Theoutput may be used to activate ventilation controls, warning signs, activationof other alarm devices etc. during fire situations.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 70 µAQuiescent @ 35 V 100 µAAlarm< 3.5 mAAux. Supply (24V DC) Quiescent 22 mAAux. Supply (24V DC) Alarm < 50 mAEnd-of-line resistorNARelay contact rating2½A @ 250 VACEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)117 x 80 x 44 mmOrdering InformationKAL430Relay Module - 1 Relay• Easy numeric addressing• Externally powered• Normally open / normally closed operation for I/O• Surface mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 46Supervised Relay ModuleKAL440Allows for the supervision of a single, 24 Volt powered output contact on thefire system loop. This unit may be used to control for e.g. sounders in case offire conditions, but may also be used to switch any output considered crucialenough to have the cable integrity between the unit and the switch pointmonitored.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm< 3.6 mAAux. Supply (24V DC) Quiescent 23 mAAux. Supply (24V DC) Alarm 23 mA + equipEnd-of-line resistor4.7 kOhmRelay contact rating1¼ A @ 250 VACEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)117 x 80 x 44 mmOrdering InformationKAL440Supervised Relay Module• Easy numeric addressing• Externally powered• Normally open / normally closed operation for I/O• Surface mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 47Relay Module - 4 RelaysKAL434/4Provides for four potential free relay outputs for the fire system loop. Eachrelay allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts.The outputs may be used to activate ventilation controls, warning signs,activation of other alarm devices etc. during fire situations.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm10 mAAux. Supply (24V DC) Quiescent 100 µAAux. Supply (24V DC) Alarm 10 mAEnd-of-line resistorNARelay contact rating2½A @ 250 VACEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)163 x 107 x 36 mmOrdering InformationKAL434/4Relay Module - 4 Relays• Easy numeric addressing• Externally powered• Normally open / normally closed operation for I/O• Surface mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 48Addressable Manual Call PointKAL450The 400 Series modules consists of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from <strong>GE</strong>Interlogix. The KAL450 is an addressable manual call point for manual fireactivation.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 90 µAQuiescent @ 35 V 120 µAAlarm< 3.5 mAAux. Supply (24V DC) Quiescent NAAux. Supply (24V DC) Alarm NAEnd-of-line resistorNARelay contact ratingNAEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h) 87 x 87 x 20Ordering InformationKAL450Addressable Manual Call PointKAL450C KAL450 spare glasses (10-pack) (DM711)KAL450E KAL450 accessory for flush mountingKAL450S KAL450 Surface mount back box (DM787)KAL450T KAL450 Anti-tamper plastic cover (DM782)DM800Resettable element for MCP DM700/KAL450• Easy numeric addressing• Loop powered• Local test facility• Surface or flush mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


AccessoriesPage 49Spare glasses (10-pack)DM715DM715 spare glasses (10-pack) - replacement glass for manual call pointOrdering InformationDM715Spare glasses (10-pack)• prEN54 pt11 standard glassKAL450 accessory for flush mountingKAL450EThe KAL450E accessory for flush mounting allows for the KAL450 and PK10manual call points to be flush mounted.• Allows for the KAL450 and PK10 to be flush mountedOrdering InformationKAL450EKAL450 accessory for flush mounting


AccessoriesPage 50Surface mount back boxDM787The DM787 is an accessory for surface mounting / surface mout back box forthe KAL450 and PK10C manual callpoints. The KAL450C is availble in RED.Ordering InformationDM787Surface mount back box• Surface mount back box for MCP - REDAnti-tamper plastic coverDM782The DM782 anti-tamper plastic cover is a protection cover for the KAL450 andPK10 manual call points. It prevents accidental activation of the alarm byenforcing a two step action i.e. lifting the cover, then activating the alarm.Ordering InformationDM782Anti-tamper plastic cover• Unobtrusive• Transparent• Protects from accidental alarm activation


I/O ModulesPage 51Digital Input ModuleKAL460Provides a remote input to the fire system loop. The input is constantlymonitored and its status communicated to the fire control panel. The inputmay be activated by closing or opening a potential free contact, depending onthe module configuration.This module may be used to monitor any contact by showing its statusthrough the fire control panel e.g. the monitoring of pressure equipment andclosure fire break doors.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm< 10 mAAux. Supply (24V DC) Quiescent 200 µAAux. Supply (24V DC) Alarm < 50 mAEnd-of-line resistorNARelay contact ratingNAEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)117 x 80 x 44 mmOrdering InformationKAL460Digital Input Module• Easy numeric addressing• Externally powered• Normally open / normally closed operation for I/O• Surface mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 52Isolator ModuleKAL470The 400 series modules consist of a complete range of interfaces developedfor input/output control in the KSA700/FP1500 analogue fire systems from <strong>GE</strong>Interlogix. The KAL470 is an isolator module in this series that isolates thefaulty zone on a fire panel loop during short circuit conditions. The KAL470does not use an address on the loop.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm10 mAAux. Supply (24V DC) Quiescent NAAux. Supply (24V DC) Alarm NAEnd-of-line resistorNARelay contact ratingNAEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +50°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)75 x 45 x 28 mmOrdering InformationKAL470Isolator Module• Requires no device address• Automatic reset• Local status indication• Surface mount• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 53Retention Module - 1 Input / 1 OutputKAL490Provides a remote input and a potential free voltage relay output to the firesystem loop. The input signal is constantly monitored and its status displayedon the control panel, whilst the output is fail-to-safe. Auxiliary supplymonitoring is also included.The module is used to for e.g. control and monitor doors such as fire breakdoors. The relay provides the door activation and the input monitors the doorstatus.Technical DataSupply voltage22-38 VDCCurrent consumptionQuiescent @ 24 V 110 µAQuiescent @ 35 V 135 µAAlarm10 mAAux. Supply (24V DC) Quiescent 200 µAAux. Supply (24V DC) Alarm < 50 mAEnd-of-line resistorNARelay contact rating1A @ 30 VAC/VDCEnvironmentalStorage temperature-10 to +50°COperating temperature -10 to +70°CRelative humidity (non-condensing) 0-95 %Dimensions (l x w x h)117 x 80 x 44 mmOrdering InformationKAL490Retention Module - 1 Input / 1 Output• Easy numeric addressing• Externally powered• Normally open / normally closed operation for I/O• Surface mount• Aesthetically pleasing• Local status indication• Part of a family of I/O modules consiting of:• - Conventional Zone Monitors• - Digital Input Modules• - Extinguishing Control Modules• - Isolator Modules• - Manual Call Points• - Output Units• - Retention Units• - Supervised Output Units for sounder control


I/O ModulesPage 54Addressable loop powered sirenSK07AThe SK07A loop powered siren is designed for connection to and control by theKSA700/FP1500 analogue fire detection systems from <strong>GE</strong>-Interlogix.Communication is done digitally between the fire panel and the sounder.Technical DataElectricalSupply Voltage22 - 38 VDCQuiescent current 300 µAAlarm current3 mA @ 85 dBA or less than 20 mA @ 95 dBAMaximum sound level95 dBAMechanicalDimensions63 mm (h) x 93 mm ØMaximum cable size2.5 mm²Fastening Screws2 x 30 mmEnvironmentalWorking temperature -20 °C to +50 °CStorage temperature -20 °C to +70 °CRelative humidity (maximum) 95 %Protection IndexIP445Ordering InformationSK07AAddressable loop powered siren• EN54 part 3 compliant• Up to 95 dBA sound output• Different alarm tones and sound levels• Low current consumption• Low profile• IP445 protection level• Easy installation• Polarity sensitive• Rear and side cable entry possible• Low and easy maintenance


SoftwarePage 55KSA700 Configuration software kitPCC-ConfigPCC-Config allows easy, menu driven, programming of all the features andsettings of the panel. Common texts can be easily copied to sensors andzones. Programming becomes simple as all settings are displayed for theprogrammers convenience.Technical DataHardware RequirementsCommunicationRS232, Modem and/or TCP/IPDisplayVGA or higher resolutionHard Disk2 GB with 650 MB free spaceKeyboardRequiredPointing DeviceRequiredPrinterSystem printer required for printingProcessor133 MHz or higher Pentium-compatible CPURAM64 Mb or moreRemovable Media1.44 Mb stiffy and CD-ROM or DVD driveSoftware RequirementsOperating System Windows ‘98 or Windows 2000Ordering InformationKSP700PC Interface & Software for up/download configuration for KSA702/5PCC-Config KSA700/FP1500 Configuration software kit• Windows based• Complete external configuration of the installation• Configuration possibilities for single and networked firesystems• Local or remote operation via modem or TCP/IP• Standard RS232 communicationGraphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (1 panel-2 loops)PCG-Graphic102The PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-Config102 operates with a single panel and allows for the configurationof all devices up to a maximum of two loops.Technical DataHardware RequirementsCommunicationRS232, Modem and/or TCP/IPDisplaySVGA or higher resolutionHard Disk2 GB with 650 MB free spaceKeyboardRequiredPointing DeviceRequiredPrinterSystem printer required for printingProcessor1 GHz or higher Pentium III-compatible CPURAM256 Mb or moreRemovable Media1.44 Mb stiffy and CD-ROM or DVD driveSoftware RequirementsOperating System Windows ‘98 or Windows 2000• Bi-directional communication with single panels and networkedfire systems• Local or remote connection via modem or TCP/IP• Large selection of user configurable icons• Visualises device alarms and status of in- and outputs• Event texts retrieval from the panel• Configurator and operator contol levels• Navigation buttons allowed• Event logs with reporting facilities• Basic drawing package included• Imports bmp & drw format graphicsOrdering InformationPCG-Graphic102Graphic Software for KSA700/FP1500 <strong>Fire</strong> <strong>Systems</strong> (1 panel-2 loops)


SoftwarePage 56Graphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (1 panel-5 loops)PCG-Graphic105The PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-Config105 supports a single panel up to 5 loops.Technical DataHardware RequirementsCommunicationRS232, Modem and/or TCP/IPDisplaySVGA or higher resolutionHard Disk2 GB with 650 MB free spaceKeyboardRequiredPointing DeviceRequiredPrinterSystem printer required for printingProcessor1 GHz or higher Pentium III-compatible CPURAM256 Mb or moreRemovable Media1.44 Mb stiffy and CD-ROM or DVD driveSoftware RequirementsOperating System Windows ‘98 or Windows 2000• Bi-directional communication with single panels and networkedfire systems• Local or remote connection via modem or TCP/IP• Large selection of user configurable icons• Visualises device alarms and status of in- and outputs• Event texts retrieval from the panel• Configurator and operator contol levels• Navigation buttons allowed• Event logs with reporting facilities• Basic drawing package included• Imports bmp & drw format graphicsOrdering InformationPCG-Graphic105Graphic Software for KSA700/FP1500 <strong>Fire</strong> <strong>Systems</strong> (1 panel-5 loops)Graphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (multi-panel)PCG-GraphicNWThe PCG-Config series consists of 3 software applications. The individualsoftware formats allows the graphic package to grow with the installation.PCG-ConfigNW allows for monitoring on networked systems with multiplepanels.Technical DataHardware RequirementsCommunicationRS232, Modem and/or TCP/IPDisplaySVGA or higher resolutionHard Disk2 GB with 650 MB free spaceKeyboardRequiredPointing DeviceRequiredPrinterSystem printer required for printingProcessor1 GHz or higher Pentium III-compatible CPURAM256 Mb or moreRemovable Media1.44 Mb stiffy and CD-ROM or DVD driveSoftware RequirementsOperating System Windows ‘98 or Windows 2000• Bi-directional communication with single panels and networkedfire systems• Local or remote connection via modem or TCP/IP• Large selection of user configurable icons• Visualises device alarms and status of in- and outputs• Event texts retrieval from the panel• Configurator and operator contol levels• Navigation buttons allowed• Event logs with reporting facilities• Basic drawing package included• Imports bmp & drw format graphicsOrdering InformationPCG-GraphicNWGraphic Software for KSA700/FP1500 <strong>Fire</strong> <strong>Systems</strong> (multi-panel)


<strong>Fire</strong> Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1Conventional fire alarm panel with 2 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NKB602 . . . . . . . . . . . . . . . . . . . . . . . . . 1Conventional fire alarm panel with 4 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NKB604 . . . . . . . . . . . . . . . . . . . . . . . . . 2Conventional fire alarm panel with 6 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NKB606 . . . . . . . . . . . . . . . . . . . . . . . . . 3Conventional fire panel with 2 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK702 . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Conventional fire panel with 4 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK704 . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Conventional fire panel with 8 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK708 . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Conventional fire panel with 12 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK712 . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Conventional fire panel with 16 fire alarm zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK716 . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Conventional extinguishing control panel with 3 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK703 . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Extinguishing Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Conventional extinguishing control panel with 5 zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NK706 . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Relay module, 4 supervised relays for NK700/Fx400 fire panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .SB404. . . . . . . . . . . . . . . . . . . . . . . . . . .11Relay module, 4 potential free relays for NK700/Fx400 fire panels . . . . . . . . . . . . . . . . . . . . . . . . . . .RB404 . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11Analogue addressable fire detection panel - 1 loop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA701/1 . . . . . . . . . . . . . . . . . . . . . . . 12<strong>Fire</strong> Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12Analogue addressable fire detection panel - 2 loops . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA701/2 . . . . . . . . . . . . . . . . . . . . . . . 13Analogue addressable fire panel (expandable to 5 loops) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA705. . . . . . . . . . . . . . . . . . . . . . . . .14Analogue addressable fire panel with printer (expandable to 5 loops) . . . . . . . . . . . . . . . . . . . . . . . KSA705P . . . . . . . . . . . . . . . . . . . . . . . . 15KSA700 Series LCD Repeater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KSA701R . . . . . . . . . . . . . . . . . . . . . . . 16Repeater Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16GSM Modem for <strong>Kilsen</strong> <strong>Fire</strong> Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MODGSM . . . . . . . . . . . . . . . . . . . . . . . 17Expansion Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17RS232 communications module for KSA702/5 control panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KAL732 . . . . . . . . . . . . . . . . . . . . . . . . . . 18Loop driver module for KSA702/705 control panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KAL701 . . . . . . . . . . . . . . . . . . . . . . . . . . 18RS485 expansion kit for KSA701/FP1500 fire panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NC785 . . . . . . . . . . . . . . . . . . . . . . . . . . . 19RS485 communications module for KSA702/5 control panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KAL785 . . . . . . . . . . . . . . . . . . . . . . . . . . 19CO detection control panel - 4 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260/4-ING . . . . . . . . . . . . . . . . . . 20CO detection control panel - 5 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260/5-ING . . . . . . . . . . . . . . . . . . 20CO detection control panel - 3 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260/3-ING . . . . . . . . . . . . . . . . . . 20CO detection control panel - 2 Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260/2-ING . . . . . . . . . . . . . . . . . . 20CO detection control panel - 1 Zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260/1-ING . . . . . . . . . . . . . . . . . . 20CO Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20CO detection expansion module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM260-ING . . . . . . . . . . . . . . . . . . . . 21CO detector with base and mounting supplement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KM170 . . . . . . . . . . . . . . . . . . . . . . . . . . 22Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23Aspiration Smoke Detector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASD20 . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Power supply unit with battery charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FC252 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Power supply unit with battery charger 0.8A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FC251 . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24Illuminated warning sign (No text) 24VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KR24B . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<strong>Fire</strong> indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25Ionisation detector, conventional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KL700 . . . . . . . . . . . . . . . . . . . . . . . . . . . 26<strong>Fire</strong> Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26Temperature detector (fixed and rate-of-rise), conventional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KL710 . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Optical detector, conventional (with field exchangeable optical block) . . . . . . . . . . . . . . . . . . . . . . . KL731 . . . . . . . . . . . . . . . . . . . . . . . . . . . 28KL731/DP331I Calibration Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KCT731 . . . . . . . . . . . . . . . . . . . . . . . . . 29Test and Service Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29Analogue addressable ionisation sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KL700A . . . . . . . . . . . . . . . . . . . . . . . . . . 30<strong>Fire</strong> Detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30Analogue addressable temperature sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KL710A . . . . . . . . . . . . . . . . . . . . . . . . . . 31Analogue addressable optical sensor (with field exchangeable chamber) . . . . . . . . . . . . . . . . . . .KL731A . . . . . . . . . . . . . . . . . . . . . . . . . . 32Analogue addressable dual (optical and thermal) sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KL735A . . . . . . . . . . . . . . . . . . . . . . . . . . 33<strong>Fire</strong> sensor programmer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .PG700 . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34Surface mount supplement for KL300 detectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S300. . . . . . . . . . . . . . . . . . . . . . . . . . . . .35<strong>Fire</strong> Detector base for KL300 series devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KZ300. . . . . . . . . . . . . . . . . . . . . . . . . . .35


Bases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35Conventional fire detector base with diode KZ705D36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . .Surface mount accessory for KZ700/DB304 and KZ700 series bases S70036. . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . .Universal fire detector base with earth connection KZ70537. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . .Universal fire detector base (for KL700 and KL700A series detectors) KZ70037. . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . .Active end-of-line device for use with FP400/KL700 fire panels EOL-ACT38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . .Analogue fire detector base with isolator KZ705I39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .Conventional fire detector base with relay KZ705R39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . .Analogue fire detector base with sounder KZ705AS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . .40Analogue fire detector base with isolator and sounder KZ705IAS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .41Conventional Zone Monitor Unit - 1 Zone KAL410. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .42I/O Modules 42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Conventional Zone Monitor Unit - 4 Zones KAL414/443. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .Extinguishing Control Module KAL426. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .44Relay Module - 1 Relay KAL430. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .45Supervised Relay Module KAL440. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .46Relay Module - 4 Relays KAL434/447. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . .Addressable Manual Call Point KAL450. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . .48KAL450 accessory for flush mounting KAL450E. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . .49Spare glasses (10-pack) DM715 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Accessories 49. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Anti-tamper plastic cover DM782 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Surface mount back box DM787 50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Digital Input Module KAL460. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51I/O Modules 51. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Isolator Module KAL470. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52Retention Module - 1 Input / 1 Output KAL490. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53Addressable loop powered siren SK07A 54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Graphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (1 panel-2 loops) PCG-Graphic102 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .KSA700 Configuration software kit PCC-Config 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Software 55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Graphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (multi-panel) PCG-GraphicNW 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Graphic Software for KSA700 <strong>Fire</strong> <strong>Systems</strong> (1 panel-5 loops) PCG-Graphic105 56. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!