11.07.2015 Views

pulse oximeters

pulse oximeters

pulse oximeters

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>pulse</strong> <strong>oximeters</strong>V3304 Pulse Oximeter with SAC TechnologySpecificationsRespiration<strong>pulse</strong> <strong>oximeters</strong>• Internal rechargeable battery• Easy-to-read LED display with adjustablebrightness• Variety of reusable sensors designed for animalapplications• Quantitative <strong>pulse</strong> strength bar• Advanced Digital SAC oximetry for demandingresearch environmentsUsing refined noise-reduction hardware (digital processing) and a uniquepatented software algorithm Serial Auto Correlation (SAC ), the V3304 isable to look at <strong>pulse</strong> oximetry data in a whole new way. This innovativeoximeter technology analyzes a digital signal at a rate of 120 times persecond and compares it to previous <strong>pulse</strong> data. These <strong>pulse</strong>s areconstantly stored and updated, and used as dynamic templates todetermine the validity or invalidity for newly encountered pulsatile signals.The V3304 offers the same advanced features as the V3402, see page F58,but in a table top package with extended data storage capabilities. Threeuser-selectable averaging modes are available, visual and audibleindicators for SpO 2and <strong>pulse</strong> rate, an 8 segment LED bar indicator for<strong>pulse</strong> strength as well as high and low limit adjustable alarms for SpO 2and <strong>pulse</strong> rate. Low priority alarms warn the user of system setupmalfunctions such as a disconnected probe. The audible indicators andalarms vary in rate and pitch to indicate changes in <strong>pulse</strong> rate and SpO 2level, respectively.Animal IDs from 0-99 are used by the V3304 to delineate multiple animaldata measurements. An optional serial printer PY2 72-3173, is availablewhich can be used to output animal data in continuous data log mode(every 5 seconds) or trend mode (every 4-30 seconds). Trend datacontinues to be stored even when data is being printed using the data logmode. The V3304 can store up to 90 hours of trend data for up to 99individual animals. The trend storage interval is user selectable from 4-30seconds. Decreasing the trend storage interval decreases the maximumlength of time data can be stored in memory. Output of data to a computerrequires the use of PY2 72-3166 printer interface cable and PY2 72-3155PC adapter cable.The V3304 Pulse Oximeter comes with an instruction manual, ACadapter/charger, PY2 72-3157 5 foot oximeter extension cable,PY2 72-3254 Reflectance Sensor, PY2 72-3256 Universal ”Y” Sensor. Theunit is powered by an internal rechargeable lead acid battery. Other <strong>pulse</strong>oximeter probes and accessories are available, see to the right.SpO 2& Pulse Rate 3-digit LED display, 10.9 mm (0.43 in) highSpO 2:Range 0 to 100%Accuracy ±2% at 70 to 100% ±3% at 50 to 69%Alarm RangeAveragingPulse Rate:RangeAccuracyAlarm RangeHigh: 50 to 100% and Off (1% steps)Low: 50 to 99% and Off (1% steps)4, 8, or 16 <strong>pulse</strong> beat average20 to 350 BPM±1 beat or 2% whichever is greaterHigh: 5 to 350 BPM and Off (5 BPM steps)Low: 5 to 350 BPM and Off (5 BPM steps)Averaging 8 or 16 sec averageBattery LifeStandard Lead-Acid battery: Internal rechargeable;not user replaceable. Fully charges in about 6 hrs.Approximately 4.5 hrs continuous usePrinter OutputSpO 2and <strong>pulse</strong> rate can be printed every five (5) sec(data log). Data saved every four (4) to thirty (30) seccan be printed (trend) Analog Output (optional) DigitalOutput (optional)Safety Approvals Designed to meet IEC-601-1, CSA 125, UL 544, and CE(EMC)AC Charger Voltage Requirements:105 to 125 VAC, 60 Hz 100 V – Hz230 VAC; 50/60 Hz (Optional)Dimensions, H x W x D 216 x 82 x 140 mm (3.4 x 8.5 x 5.5 in)Weight810 grams (1.8 lbs)Order # ProductPY2 72-3174 V3304 Digital Table Top Pulse Oximeter, 110 VAC, 60 HzPY2 72-3264 V3304 Digital Table Top Pulse Oximeter, 220 VAC, 50 HzSensors and Sensor AccessoriesPY2 72-3256 Universal “Y” SensorPY2 72-3254 Reflectance SensorPY2 72-3157 Oximetry Cable, 5 ft.PY2 72-3163 Oximetry Simulator with 5 ft. CableOptional AccessoriesPY2 72-3179 Printer Interface CablePY2 72-3180 PC Interface CablePY2 72-3178 Digital Output AdapterPY2 72-3177 Analog Output AdapterPY2 72-3175 IV Pole BracketF68Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!