Dimensions for Ventex type ESI-E, ESI-D & ESI-RFig 4: valve dimensionsSizeL(mm)D(mm)Weight(Kg)ESI-E ESI-D ESI-RPressure drop (mbar) Pressure drop (mbar) Pressure drop (mbar)at 15 m/s at 20 m/s at 15 m/s at 20 m/s at 15 m/s at 20 m/sA B A BDN100 350 265 44 2.9 3.5 5.0 6.02.8 4.3*4502.9 5.0DN200 610 400 52 1.9 2.3 3.4 4.1 1.9 3.4 4.9 6.8DN300 780 550 82 1.2 1.8 2.2 3.1 1.2 2.2 3.8 6.1DN400 940 720 132 2.4 2.7 4.3 4.8 2.4 4.3 6.1 7.8DN500 1300 900 215 4.7 5.8 8.4 10.5 4.7 8.4 7.3 12.8DN600 1420 929 305 4.0 5.0 7.0 8.8 4.0 7.0 - -DN700 1530 1220 460 4.8 4.8 8.5 8.5 4.8 - - -(*) for type ESI-DA: with explosion flowB: against explosion flowSpecificationsTypesESI – E Single Acting <strong>Explosion</strong> <strong>Isolation</strong> <strong>Valve</strong>ESI – D Double Acting <strong>Explosion</strong> <strong>Isolation</strong> <strong>Valve</strong>ESI – R <strong>Explosion</strong> <strong>Isolation</strong> Check <strong>Valve</strong><strong>Explosion</strong> hazardST 1 & ST 2 dustsHybrid: contact Fike for assistanceP EXDN100-500: 10 bar maximumDN700: 5 bar maximumIn combination with ventingP stat 0.2 barg minIn combination with suppressionP a 0.2 barg min<strong>Explosion</strong> Tested atDMT, Dortmund/ FSA, Mannheim/ Ciba Geigy, BaselRequired dP to close the <strong>Valve</strong>0.1 bar minMaximum Operating Temperature Neoprene Gaskets: T max 90°CEPMD Gaskets: T max 120°CSilicone Gaskets: T max 150°CFPM Gaskets: T max 150°CHigh Temperature Silicone Gaskets: T max 260°CMaximum Flow Velocityv max = 20 m/secMin. Installation Distance X min5 meters from explosion sourceMax. Installation Distance X max12.5 meters from explosion sourceMaterial specification Type A: Mild steel painted red (Nitro-synthetic resin top coat RAL 3020) valvebody; AISI 304 (W1.4301) internal part. Wetted parts: mild steel / AISI304Type C: AISI 304 (W1.4301) valve body; AISI 304 (W1.4301) internal parts.Wetted parts: AISI 304Type E: AISI 316 L (W1.4435) valve body and internal parts. Wetted parts: AISI316 LFlanges DIN 2576, PN 10LeakageOptionsStandard valves are not gastightPosition indicators (valve open/ valve closed), also available for use inEx classified areasHigher process temperaturesVertical installationOther surface treatmentMating flanges, gaskets, studs and nutsANSI flangesGastight (DIN 3230 BO L1) up to 2 or 10 bar


Application guideThe explosion hazard: The barrier valve can be used to provide protection against the propagation of ST 1 & ST 2 dust explosions(K max ≤ 299 bar∙m/s) and hybrid mixtures characterised by a maximum vapour or gas concentration of 50% of the lower explosionlimit (LEL). The valves withstand an explosion overpressure P EX of 10 bar (5 bar for the DN 700 size valve).In combination with venting: If the vessel to which the pipe is connected is protected by explosion venting, the static activationpressure P stat of the explosion vent should be ≥ 0.2 bar to guarantee reliable performance of the valve.In combination with suppression: If the vessel to which the pipe is connected is protected by explosion suppression, the staticactivation pressure P a of the suppression system should be ≥ 0.2 bar to guarantee reliable performance of the valve.Minimum and maximum installation distances from the vessel being protected are: minimum 5 m and maximum 12.5 m. Thetype ESI-R explosion isolation check valve has a reduced minimum installation distance of 1.5 m for K St values below 500 bar.m/s.These distances are for reference only and should be carefully engineered depending on the explosion hazard, the explosionoverpressure (P max or P red ) in the connected vessel and the valve size.Installation: The Ventex valves are designed to be installed horizontally, however as an option they can be factory set for verticalinstallation.Dust load: The valve has been designed for use in clean air process pipes. If intended for use in dust-laden pipes, the applicationshould be reviewed carefully and may require process modifications and short service intervals.Examples of applicationHot air inletA Ventex valve installed in the air intake pipe will prevent explosion pressure damage to the heat exchanger in the event ofan explosion originating from the drying chamber of a spray / flash dryer system or atomiser. In the example below represents the slurry feed pipe.Fig 5 Photo 1


Pneumatic conveyingA Ventex valve installed in the clean air outlet pipe of the dustfilter will prevent explosion damage to the fan if an explosionoccurs in the cyclone or filter . The Ventex valve installed in the clean air intake of the pneumatic conveying pipe thattransports the product from cyclone to other process areas, will prevent explosion propagation into the manned process area . Inthis application an explosion isolation of the valve prevent explosion propagation from the product outlet of the cyclone. Theexplosion isolation of the dust-laden product inlet is achieved by Fike chemical or mechanical active explosion barrier system .Further informationThe above applications identify the use of passive explosion isolation valves on the clean air inlets and outlets.Fike’s “Total Concept <strong>Explosion</strong> Protection” provides solutions for other explosion protection requirements.<strong>Explosion</strong> Venting Bulletin N° 8.0300.00FlamQuench Bulletin N° 8.4000.00<strong>Explosion</strong> <strong>Isolation</strong> <strong>Valve</strong> Bulletin N° 8.5500.00<strong>Isolation</strong> Container SRD Bulletin N° 8.5501.00Suppression Container HRD Bulletin N° 8.6501.00Fig 6 Photo 2All above data are subject to change without notice. They must not be used unless confirmed in writing.8.7000.00.1Fike Europe B.v.b.a. · Toekomstlaan 52 · B2200 Herentals · BelgiumTel. +32 14 210031 · Fax +32 14 210743 · email fike-europe@fike.com · Website http://www.fike.beFike United Kingdom · Maidstone · EnglandTel. (01622)677081 · Fax (01622)685737 · email sales@fike.co.uk · Website http://www.fike.co.uk

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!