Rupture IndicatorType RI – RI2 – BC2 – BC-HDescriptionThe Fike Indicator will give instant warning that a bursting disc hasruptured, and that products may be venting into the atmosphere, orthat product may be lost or contaminated if the bursting disc is notimmediately replaced. It can interlock with control equipment inorder to stop or alter the process. If the bursting disc or safety valverelieves into a common header the signal obtained from the RI willindicate the location of the problem.RI / RI2The RI consists of an insulated electrically conductive strip attachedto a stainless steel baffle, which is supported by a stainless steelring. The RI is equipped with a built-in self-resetting fuse forprotection against unacceptably high currents.Compared to the standard RI, the RI2 includes additional series andend of line resistors to provide a full wiring supervision. The RI2burst indicator offers a high Safety Integrity Level: SIL 2 according toIEC61508. Both indicators are supplied with 3m of electrical wire.BC2The BC2 consists of an insulated conductive strip attached to aTeflon film. As a standard the BC2 is supplied with 18” (0,46m) ofelectrical wire and a 3-pin quick connector plug.BC-HThe BC-H is specifically designed for use with the SR-H, AXIUSSC or SHX hygienic service bursting disc. As a standard the BC-His supplied with 18” (0,46m) of electrical wire and a 3-pin quickconnector plug.<strong>BURSTING</strong> <strong>DISC</strong> <strong>ACCESSORIES</strong>Features and Benefits• Rigid flange construction• Corrosion resistant• Easy replacement upon disc ruptures• Compatibility with standard design burstingdiscs and safety relief valves• High mechanical rigidity• Simple “plug & play” design• Integral self-resetting electrical fuse (RI, RI2)• Complete wiring supervision (RI2 only)• IEC61508-SIL2 approved (RI2 only)BC2BurstingDiscBC2BurstingDiscNote:The RI, RI2 and BC2 / BC-H TM are designed for use withintrinsically safe electrical alarm or control equipment, whichis initiated by an open-circuit signal.MountingThe Fike burst indicators can be mounted on the vent side of a bursting disc assembly or safety relief valve. Forlarge bursting discs (> DN150/6”) a spacer ring may be required to prevent contact between the protruding domeof the bursting disc and the burst indicator.8.1800.00.7


Technical DataModel RI / RI2 BC2 BC-H TMConfigurationFlatSizes DN25-DN300 / 1”-12” DN15-DN600 / ½”-24” DN40-DN100 / 1½ ”-4”Gasket (1) Non Asbestos Silicone (3)Baffle SST N/AMaterialConductorCu-foil laminated between Kapton ® -filmRing (2) SSTSeal N/A Teflon ®Gasket (1) Non Asbestos Silicone (3)Max. Process Temperature 260°C 175°C (3)Max. Ambient Temperature 65°CMax. VoltageMax. Current24VAC/DC50mAMax. Resistance before Rupture 30Ω 2Ω 2ΩLength (4) 3m 18” (0,46m)Type 1x2x0,5mm 2Electrical CableMaterials PVC shielded and insulated PTFE shielded and insulatedColourBlueMax. Temp. 80°CElectrical Connector N/A 3-PIN Quick ConnectAlternative Cable Length (extensions) Optional 10m & 25m See note (4)Designed / certified for use in Explosion ProofElectrical circuitry perRI: EEx ia IIC T6Atex II 1G/DRI2: II 1 G - Ex ia IIB T4II 1 D - Ex iaD 20 T135°CEEx ia IIB T6Atex II 1 G/DUse betweenStandard FlangesANSI 150/300/600ANSI 16.31/16.5Yes Yes NoEN1092-1 Yes Yes NoTriclamp connectionDIN 32676 / ISO 2852No No YesNotes:(1) Standard gaskets are asbestos-free (AFM34) on RI, RI2 & BC2 and Silicone on BC-H TM . Other materials, such as Teflon, can be supplied on request.Consult factory.(2) Standard material of construction is 1.4301 (304 SST) for BC2 & BC-H, 1.4404 (316L SST) for RI & RI2. Other materials are available on request.(3) Other materials, Viton or EPDM (max. temp. 150°C) are available on request.(4) The BC2 and BC-H TM are supplied with 18” (0,46m) of cable which has a 3 Pin Plug and Socket. A lead cable in lengths of 10’ (3m) and 25’ (7,6m) withquick connector plug is available on request.Table - Minimum ∆P (mbarg) required for functioning (1)TypeRI / RI2DN - - 25 40 50 65 80 100 125 150 200 250 300Size Inch - - 1 1 ½ 2 2 ½ 3 4 5 6 8 10 12Minimum ∆P required (mbarg) - - 1800 800 600 500 430 350 300 260 210 175 160Relief Area (cm²) - - 4,52 7,07 13,85 22,06 34,73 65,76 114,99 161,73 286,52 461,86 615,75TypeDN 15 20 25 40 50 - 80 100 - 150 200 250 300Size Inch ½ ¾ 1 1 ½ 2 - 3 4 - 6 8 10 12Minimum ∆P required (mbarg) 2483 2345 690 552 552 - 483 483 - 414 311 249 207Relief Area (cm²)TypeBC-HBC2Select Relief Area of upstream discDN - - 25 40 50 - 80 100Size Inch - - 1 1 ½ 2 - 3 4Minimum ∆P required (mbarg) - - 690 552 552 - 483 483Relief Area (cm²) - - Select Relief Area of upstream discNote: (1) Subject to the rate of pressure rise, minimal fragmentation may occur.8.1800.00.7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!