<strong>Auxiliary</strong> <strong>Valve</strong><strong>QDS6</strong>Sequence <strong>Valve</strong>, 3-wayCatalogue HY17-8542/UKJune 2003


Catalogue HY17-8542/UK/USGeneral<strong>Auxiliary</strong> <strong>Valve</strong>s<strong>QDS6</strong>Subject to alteration without prior notice. The curves anddiagrams in this catalogue are typical examples only. While thecontents of the catalogue are updated continuously, the validityof the information given should always be confirmed. For moredetailed information, please contact Parker.2 Parker HannifinMobile Controls DivisionBorås, Sweden


Catalogue HY17-8542/UK/USGeneral Information<strong>Auxiliary</strong> <strong>Valve</strong>s<strong>QDS6</strong>ApplicationsThe <strong>QDS6</strong> sequence valve is designed toopen or close a hydraulic pilot signal (thatcomes from an external source) when itreaches a predetermined pressure level.Common applications of the valve are inpilot logic circuits and sequence-controlsub-circuits. One example of use is as ameans of load-moment limitation(overload protection) in the liftingfunctions of mobile cranes, in conjunctionwith hydraulic remote control. In suchcases, the <strong>QDS6</strong> is used to break the pilotsignal between the control valve andthe directional valve when the signalpressure reaches a predetermined valueset on the <strong>QDS6</strong>.Construction and functionThe <strong>QDS6</strong> is a three-way, pilot-operatedvalve. Its directional function is normallyopen or normally closed.The valve housing is manufacturedfrom continuously-cast grey iron and containsa precision-ground spool and pilotsection.When the pilot signal exceeds thepreset switching pressure, the spoolchanges position, thus blocking P andconnecting S with T. Alternatively, T isblocked and S connected with P (seefigure on page 4). The spool is positivelyoverlapped, i.e. it closes the one connectionbefore opening the other. The pilotsection can be drained either internally orexternally. Pilot sections with externaldrainage can be fed with an externalpressure in the drainage connection toobtain a higher switching pressure thanthe one preset.Advantages• Compact - easy to install.• Several pressure ranges available -enables high setting precision.• Easy to adjust pressure within specifiedpressure range - facilitates finetuning.• Can be factory-set and sealed - preventsunauthorized pressure changing.• Withstands high pressure shocks inthe tank connection - gives long servicelife in systems with high intermittenttank pressure.• Simple design - gives great reliability.Optional equipmentNumerous other options are available forthe <strong>QDS6</strong>. For further information, pleasecontact your Parker representative.• Hand wheel for easy changing of pressuresetting.• Flanged version of <strong>QDS6</strong> for flangingdirectly to, e.g. a valve block.3 Parker HannifinMobile Controls DivisionBorås, Sweden


Catalogue HY17-8542/UK/USTechnical DataPossible pressure setting ranges(applicable range will depend on pressure setting you specify)Switching pressure4-10 bar11-20 bar21-30 bar31-45 bar46-150 bar150-250 barWorking pressureMax. 250 barTank pressureMax. 250 bar in pressure shocks.Recommended flow rateMax. 20 l/minConnectionsAll connections are available in two versions:- G1/4 (BSP pipe thread) for flat seal (type Tredo) according toISO 228/1.- 9/16-18 UNF-2B for O-ring seal according to SAE J1926/1.LeakageAt pressure differential of 100 bar and viscosity of 30 mm/s 2 :P to S max. 12 cm 3 /minS to T max. 12 cm 3 /minP to X max. 5 cm 3 /minWeightApprox. 1.0 kg<strong>Auxiliary</strong> <strong>Valve</strong>s<strong>QDS6</strong>∆ p (bar)353025201510500 5 10 15 20 25 30 35q (l/min)Pressure drop for <strong>QDS6</strong>1 = Pressure drop P-S for spool A and B2 = Pressure drop S-T for spool C and E3 = Pressure drop P-S for spool C and E4 = Pressure drop S-T for spool A and BDPSTSSpool A1234(Positively overlapped spool)XHydraulic fluidsBest performance is obtained using mineral-base oil of highquality and cleanness in the hydraulic system. HLP hydraulicfluids (DIN 51524), automatic-gearbox oil type A and API CDengine oils can be used. If in doubt, please contact Parker forfurther information.For best function, oil viscosity should be between 15 and 45mm/s 2 (cSt).PSpool BTXFiltrationFiltration should be arranged so that Target ContaminationClass 18/16/13 according to ISO 4406 is not exceeded.TemperatureTemperature range, fluid:-20 °C to + 70 °CTemperature range, ambient:-40 °C to +70 °CTemperature-shock resistance: max. 100 °C/secondGeneralTechnical data in this catalogue is applicable using mineralbase oil according to DIN 51524 at a viscosity of 30 mm 2 /s andtemperature of 50 °C.DPSSpool CTSXFor damped signalonlyXSpool EPFunctional symbols for <strong>QDS6</strong>T4 Parker HannifinMobile Controls DivisionBorås, Sweden


Catalogue HY17-8542/UK/USDimensions<strong>Auxiliary</strong> <strong>Valve</strong>s<strong>QDS6</strong>DFitted for spoolsB and E onlyTSPXFitted for damped signal only39 39(1.54) (1.54)9(0.35)27 24(1.06) (0.94)(3.62)92 A 30 max(1.18 max)32 (1.26) 9 (0.35)15(0.59)15(0.59)25 (0.98)30(1.18)50(1.97)Fixing holes ∅ 6.5 (2x)(Ø0.26 2x)A = 15 at 4 - 45 barA = 44 at 46 - 250 bar5 Parker HannifinMobile Controls DivisionBorås, Sweden


Catalogue HY17-8542/UK/USOrdering<strong>Auxiliary</strong> <strong>Valve</strong>s<strong>QDS6</strong>When ordering your <strong>QDS6</strong> sequence valve, please make use ofthe ordering-code system as per the example given in the chartbelow. For certain standard valve settings, however, there aredirect ordering numbers, which are given in the table below.CodeOrdering number<strong>QDS6</strong>G-05-B-O-O 8234 8905 75<strong>QDS6</strong>G-15-E-O-O 8234-8905 92<strong>QDS6</strong>G-25-B-O-O 8234 8905 91<strong>QDS6</strong>G-100-B-O-O 8234 8905 83<strong>QDS6</strong>G-250-E-O-O 8234 8905 88Ordering code<strong>QDS6</strong> — — — — —ConnectionSwitchingpressureSpoolfunctionDamping ofsignal XSealingCodeOPSealingNot sealed<strong>Valve</strong> sealed withsealing wire and sealCodeODDamping of signal XNot dampedDampedCodeABCESpool functionP to S normally open. External drainage of pilot section.P to S normally open. Internal drainage of pilot section.P to S normally closed. External drainage of pilot section.P to S normally closed. Internal drainage of pilot section.CodeSwitching pressure<strong>Valve</strong> is delivered preset at specifiedswitching pressure. Pressure range4 - 250 bar.CodeGUConnectionG1/4 (BSP pipe) thread9/16-18 UNF-2B thread6 Parker HannifinMobile Controls DivisionBorås, Sweden


Hydraulics GroupSales OfficesEuropeAustriaWiener NeustadtTel: +43 (0)2622 23501Fax: +43 (0)2622 66212BelgiumNivellesParc Industriel Sud-Zone IITel: +32 (0)67 280 900Fax: +32 (0)67 280 999Czech RepublicPragueTel: +420 2 830 85 221Fax: +420 2 830 85 360DenmarkIshøjTel: +45 4356 0400Fax: +45 4373 8431FinlandVantaaTel: +358 (0)9 4767 31Fax: +358 (0)9 4767 3200FranceContamine-sur-ArveTel: +33 (0)450 25 80 25Fax: +33 (0)450 03 67 37GermanyKaarstTel: +49 (0)2131 4016 0Fax: +49 (0)2131 4016 9199HungaryBudapestTel: +36 (06)1 220 4155Fax: +36 (06)1 422 1525IrelandCloneeTel: +353 (0)1 801 4010Fax: +353 (0)1 801 4132ItalyCorsico (MI)Tel: +39 02 45 19 21Fax: +39 02 4 47 93 40The NetherlandsOldenzaalTel: +31 (0)541 585000Fax: +31 (0)541 585459NorwaySkiTel: +47 64 91 10 00Fax: +47 64 91 10 90PolandWarsawTel: +48 (0)22 863 49 42Fax: +48 (0)22 863 49 44PortugalLeca da PalmeiraTel: +351 22 9997 360Fax: +351 22 9961 527SlovakiaRef. Czech RepublicSpainMadridTel: +34 91 675 73 00Fax: +34 91 675 77 11SwedenSpångaTel: +46 (0)8 597 950 00Fax: +46 (0)8 597 951 10United KingdomWatford (industrial)Tel: +44 (0)1923 492 000Fax: +44 (0)1923 256 059Ossett (mobile)Tel: +44 (0)1924 282 200Fax: +44 (0)1924 282 299InternationalAustraliaCastle HillTel: +61 (0)2-9634 7777Fax: +61 (0)2-9899 6184CanadaMilton, OntarioTel: +1 905-693-3000Fax: +1 905-876-0788ChinaBeijingTel: +86 10 6561 0520Fax: +86 10 6561 0526Asia Pacific GroupHong Kong, KowloonTel: +852 2428 8008Fax: +852 2425 6896IndiaMumbaiTel: +91 22 7907081Fax: +91 22 7907080JapanTokyoTel: +(81) 3 6408 3900Fax: +(81) 3 5449 7201Latin America GroupBrazilTel: +55 12 3954-5100Fax: +55 12 3954-5266South AfricaKempton ParkTel: +27 (0)11-392 7280Fax: +27 (0)11-392 7213USACleveland (industrial)Tel: +1 216-896-3000Fax: +1 216-896-4031Lincolnshire (mobile)Tel: +1 847-821-1500Fax: +1 847-821-7600Parker Hannifin is the world’s premier supplier of motion and control systemsand solutions, with sales and manufacturing facilities throughout the world. Forproduct information and details of your nearest Parker sales office, visit us atwww.parker.com or call free on 00800 2727 5374.Catalogue HY17-8542/UK/US0M 06/03 PDF© Copyright 2003Parker Hannifin CorporationAll rights reserved.