12.07.2015 Views

polylux - transformer - Asia Access Limited

polylux - transformer - Asia Access Limited

polylux - transformer - Asia Access Limited

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

single phase control <strong>transformer</strong>s IP - 20Control, isolating and safety <strong>transformer</strong>sSERIES PRatingVA2540631001602002503154005006308001000160020002500315040005000InputVoltage V230/ 400“ ““ ““ “230/ 400/ 460“ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ ““ “ “REFERENCESOutput Voltage6/12 VRef.PA 25“ 40“ 63“ 100“ 160“ 20012/24 VRef.PB 25“ 40“ 63“ 100“ 160“ 200“ 250“ 315“ 400“ 50024/48 VRef.PC 25“ 40“ 63“ 100“ 160“ 200“ 250“ 315“ 400“ 500“ 630“ 800“ 1000“ 1600“ 2000“ 2500115/230 VRef.PD 25“ 40“ 63“ 100“ 160“ 200“ 250“ 315“ 400“ 500“ 630“ 800“ 1000“ 1600“ 2000“ 2500“ 3150“ 4000“ 5000The only <strong>transformer</strong> that can be set from Class I to Class II.Power ‘ON’ indication by Led.Non-flammable <strong>transformer</strong> enclosure.Parts with risk of electrical contact are not accessible by the user.Terminals with fast access and easy connection.Large label with all relevant data, including instantaneous power.For cast resin <strong>transformer</strong>s, see page 10.figure 1DIMENSIONS / WEIGHTSdimensions mmRating VA A B C D E Weight kg FigureC2540631001602002503154005006308001000160020002500315040005000696984841061061061181181361361361361991991991992472479292101101123123123138138162162162162220220220220260260808098981181181181311311561561561802422422822822992997979888811011011012112114514514514518818818818823323345455555747474888810410410410417517517517522322355555556666667777770,640,791,11,62,32,73,34,14,95,86,88,610,016,822,027,632,040,147,01111111111111222222TECHNICAL CHARACTERISTICSEAfigure 2DBFrequencyInsulationWindingsProtectionTest voltageMountingCover50 - 60 HzClass B - 130º CClass HC - 200º CConvertable from class I to class II up to 1000 VA4,6 kV (1 min, 50 Hz) between primary and secondary3,2 kV (1 min, 50 Hz) between primary and earth2,5 kV (1 min, 50 Hz) between secondary and earthBy screws (all ratings)DIN Rail (for ratings up to 250 VA)Up to 1000 VA, polymer of latest technology, non-flammable V-0 according to UL94In metal enclosure, epoxy polyester painted as from 1600 VA41000VA 250VA OPTIONALProtection degreeVoltage selectionStandardsIncludesOptionalFor <strong>transformer</strong>s according to UL 506, please consult.IP - 20By metal bridges, includedIEC/EN/UNE-EN 61558 CESignal ledFuse in primary up to 2000 VA. (On request)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!