4.16 kV Line‐Line is the most commonly available voltage class of generator. Higher voltage generatoroptions are available, but would require a larger footprint.The final trade study performed was for the generator rotor configuration. The objective was todetermine the appropriate pole‐pair number (i.e., north‐south magnets on the rotor) to match theoutput frequency and rated speed of the ammonia turbine. Two practical solutions for the generatorare available. The first is a two‐pole configuration which corresponds to 3600 RPM rated speed. Thesecond is a four‐pole configuration which corresponds to 1800 RPM rated speed. The tradeoff betweenthese two options drives the size, weight, efficiency, cost, and gear reduction impact for the turbinegeneratorskid. Four‐pole, 1800 rpm configurations were found to be more widely available, one‐fourththe cost, 50% lighter, and more efficient, 97% vs. 96%, than their two‐pole cousins. Thus the four‐polegenerator option was selected for the 2.5‐MW <strong>OTEC</strong> <strong>Mini</strong>‐<strong>Spar</strong>.2.5.3.2.2 Specification of Selected EquipmentThe top‐level selected generator parameters are given below in Table 2‐26. The parameters listed arewithin the specifications for a traditional COTS generating unit. Potential vendors for this generatorinclude Cummins, ABB, Siemens, and several other domestic and international companies. Furtherdetails regarding the generator specification will be developed during the next design phase.Table 2‐26 Generator SpecificationsParameterNominal ValueTypeSynchronousOutput Power6 MVAMax‐Efficiency 97%Terminal Voltage (Line to Line) 4.16 kVFrequency60 HzSynchronous Speed1800 rpmPower Factor 0.8CoolingTotally Enclosed Water‐Air Cooled (TEWAC)2.5.3.2.3 Generator Installation IssuesInstallation of a generator on the <strong>Mini</strong>‐<strong>Spar</strong> raised two issues, operating in a marine environment andthe impact of the upending process on the generator.Configuration Report and Development Plan Volume 4Site Specific <strong>OTEC</strong> Pilot Plant 126

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!