12.07.2015 Views

PEG 400 at Low Levels by HPLC-CAD

PEG 400 at Low Levels by HPLC-CAD

PEG 400 at Low Levels by HPLC-CAD

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Corona TM Charged Aerosol Detector<strong>PEG</strong> <strong>400</strong> <strong>at</strong> low levelsApplic<strong>at</strong>ion noteThe need for universal <strong>HPLC</strong> detection inanalytical labor<strong>at</strong>ories is widespread.While several detection technologies(e.g., low wavelength UV, refractive index,evapor<strong>at</strong>ive light sc<strong>at</strong>tering, chemiluminescentnitrogen detectors) are currentlybeing used, there is significant room forimprovement in performance characteristicssuch as sensitivity, dynamic range,consistency of response factors andgradient or solvent comp<strong>at</strong>ibility.Response1.00.90.80.70.60.50.40.31.00.90.80.70.60.50.40.3Volts0.20.2To help address the many challenges ofuniversal detection, ESA has developedthe Corona <strong>CAD</strong> TM detector. This noveltechnology offers many benefits toanalytical scientists including:• High Sensitivity - <strong>Low</strong> ng limits ofdetection.• Consistent Response Factors - Responsemagnitude does not significantly dependon analyte properties (e.g. molarabsorbtivity, proton affinity).• Broad and Useful Dynamic Range - 4orders of magnitude (ng - µg quantities).• Excellent Reproducibility - Typically lessthan 2% RSD.• Broad Applicability - Can be used witha wide variety of <strong>HPLC</strong> conditions tomeasure virtually any nonvol<strong>at</strong>ile analyteincluding proteins, lipids, carbohydr<strong>at</strong>esand small molecules.• Ease of Use - Easy setup. Uses minimalbench space and requires only gas inputpressure and signal output range to beset.0.10.0-0.1-0.10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15MinutesFigure 1. <strong>PEG</strong> <strong>400</strong> stock diluted 1:1000 (v/v) in mobile phase.(Gain range = 50pA full scale).This applic<strong>at</strong>ion note describes the use of the Corona <strong>CAD</strong> forthe measurement of polyethylene glycol (<strong>PEG</strong>) <strong>400</strong> (Figure 1).The method has excellent sensitivity (Figure 2) and a dynamicrange th<strong>at</strong> covers ng to µg levels. This is an example ofdetection of analytes th<strong>at</strong> possess only a weak chromophore.Corona parametersGas: 35psi via nitrogen gener<strong>at</strong>orFilter: noneRange: variable<strong>HPLC</strong> Parameters:Mobile Phase: 65:35; w<strong>at</strong>er:methanolFlow R<strong>at</strong>e: 0.5mL/minColumn: MD150, 3.2 x 150mm; 3µmColumn Temper<strong>at</strong>ure: ambientInjection Volume: 10µLSample prepar<strong>at</strong>ionStock solution (Sigma - P3265) was diluted in mobile phase.0.10.0


The CoronaTMCharged Aerosol Detector1.01.0ConclusionsResponse0.90.80.70.60.50.40.90.80.70.60.50.4The Corona <strong>CAD</strong> provides universal detection of nonvol<strong>at</strong>ileanalytes with response independent ofchemical properties, a wide dynamic response range,high sensitivity and good precision. Thesecharacteristics, along with reliability and simpleoper<strong>at</strong>ion, make this a superior detector for a widerange of <strong>HPLC</strong> analyses.0.30.30.20.10.0-0.1-0.10 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15MinutesFigure 2. <strong>PEG</strong> <strong>400</strong> stock diluted 1:100,000 (v/v) inmobile phase. (Gain range = 1pA full scale).0.20.10.0For more inform<strong>at</strong>ion about this applic<strong>at</strong>ion, theCorona <strong>CAD</strong>, or charged aerosol detection visitwww.coronacad.com. We are interested in your opinionsand are available to answer any questions youmay have: please contact a technical represent<strong>at</strong>ive <strong>at</strong>978.250.7082, or if e-mail is more convenient, sendyour questions to coronacad@esainc.com.Ordering inform<strong>at</strong>ionDescriptionCoronaThermal Organizer ModuleNitrogen gener<strong>at</strong>or 70-6003Pump, model 582 70-4050Autosampler, model 542 70-4152Qu<strong>at</strong>ernary low pressure gradientand degasser 70-5260Elite software including PC 70-5073Column, MD150 70-0636Part Number70-6350 (100/120V)70-6351 (230/240V)70-5499TAESA, Inc. • 22 Alpha RoadChelmsford, MA 01824-4171U.S.A.Tel: (978) 250-7000Fax: (978) 250-7090www.esainc.comwww.coronacad.comESA Analytical • Brook FarmDorton, AylesburyBuckinghamshireHP18 9NHEnglandTel: 44 (0)1844 239381www.esainc.comESA, Inc. is an ISO 9001 and 13485 Certified CompanyCorona TM and <strong>CAD</strong> TM are trademarks of ESA, Inc.ESA ®is a registered trademark of ESA, Inc.The Corona <strong>CAD</strong> is covered <strong>by</strong> multiple p<strong>at</strong>ents70-6521IA-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!