12.07.2015 Views

Masonry Hangers for Solid Joists - Simpson Strong-Tie

Masonry Hangers for Solid Joists - Simpson Strong-Tie

Masonry Hangers for Solid Joists - Simpson Strong-Tie

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Masonry</strong> <strong>Hangers</strong> <strong>for</strong> <strong>Solid</strong> <strong>Joists</strong>JHM/HJHM <strong>Masonry</strong> Supported Joist <strong>Hangers</strong>TYPICAL JHM Installation JHMS Straddle Configuration JHMR Return Configuration<strong>Masonry</strong> <strong>Hangers</strong>129-150JHM HANGERS - LOADSModelJoist FastenersSafe Working Loads (kN)Block StrengthCharacteristic Capacity (kN)Block StrengthQtyNail2.8N/mm 2<strong>Solid</strong> AAC3.5N/mm 2<strong>Solid</strong> LAC7N/mm 2<strong>Solid</strong> DAC2.8N/mm 2<strong>Solid</strong> AAC3.5N/mm 2<strong>Solid</strong> LAC7N/mm 2<strong>Solid</strong> DACJHM 2 3.75x30 6.25 6.25 9.37 10.10 10.10 13.981.2.3.4.5.Loads are based upon tests conducted by CERAM Building Technology and are determined in accordance with BS 6178 and EN 845.Loads apply to masonry blocks with a minimum compressive strength as indicated.The block thickness must be at least the same size as the top flange depth (as shown in relevant illustrations).For straddle hangers the minimum S dimension is 100mm.3.75 x 30 refers to a square twist nail (not supplied with hanger).HJHM HANGERS - LOADSCatalogue C-UK10 © 2010 SIMPSON STRONG-TIE COMPANY INC.1.2.3.Size Range(mm)Joist FastenersWidth Height Qty Nail2.8N/mm 2<strong>Solid</strong> AACSafe Working Loads (kN)Block Strength3.5N/mm 2<strong>Solid</strong> LAC7N/mm 2<strong>Solid</strong> DAC2.8N/mm 2<strong>Solid</strong> AACCharacteristic Capacity (kN)Block Strength3.5N/mm 2<strong>Solid</strong> LAC7N/mm 2<strong>Solid</strong> DAC40 - 74 140 - 400 2 3.75 x 30 8.45 8.45 13.50 12.67 12.67 20.2575 - 200 140 - 400 2 3.75 x 30 10.60 10.60 13.50 15.90 15.90 20.2591 - 200 140 - 400 8 4.00 x 90 10.60 10.60 15.52 15.90 15.90 23.28201 - 300 140 - 400 2 3.75 x 30 8.50 8.50 10.80 12.75 12.75 16.35Test conducted by CERAM Building Technology in accordance with EN846-4 and evaluated in accordance with EN845-1.3.75 x 30 refers to square twist nails.Loads apply to solid block with minimum compressive strengths indicated. The block thickness must be at least the same size as the top flange length, as shown in theillustrations above. For straddle hangers the minimum S dimension is 100mm to achieve published loads, except <strong>for</strong> HJHM hangers which must be twice the top flange lengthof a single hanger.SKEWED JHM HANGERS - LOADSModelQtyJoist FastenersNail2.8N/mm 2<strong>Solid</strong> AACSafe Working Loads (kN)Block Strength3.5N/mm 2<strong>Solid</strong> LAC7N/mm 2<strong>Solid</strong> DACJHM 4 3.75x30 5.05 5.17 5.171. Maximum width 61mm2. Maximum skew 45o21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!