8SETTINGSSETTINGSATTENTION!!!!Boiler connected to the installation according to point II ELECTRICALASSEMBLY. CH (HUW) pump should be turned on for III speed. Valves onradiators should be completely open while start-up.3JEZYKPOLSKIENGLISHOKLANGUAGE1. Red diode on – no. 20, boiler stand-by – boiler turned on.2. For 5 s. Press button: Green diode no. 19 turns on.JEZYKPOLSKIENGLISHOKLANGUAGE3. Choose language POLSKI / ANGIELSKI (ENGLISH).– choose ENGLISH– back to POLISH– OK. Confirm language selection.4Venting4. On LCD – sign „venting + progress bar”. One cannot skip this part. CH(optionally HUW) pump turns on – there is no possibility to disconnectheaters. Those 5 minutes should be sufficient to vent whole systemincluding boiler and pump. In case however another venting is essentialplease repeat previous step.5c11:53:3312 05 2011 THUc1234565. On LCD – information according to description on page 7.1I – INITIAL SETTINGS:1 CH and HUW (concerns AsD-W and AsDC-W boilers only) temp. setting– press 1 time, enter function:HUW50CH50– go to CH setting– get back to HUW settingHUW.CHCONTROL PANEL5050CH and HUW temperatures are set in the same way.ESCONOFF