UniclassEPICCI/SfB(52)October 2005Drainage ProductsS E L E C T I O N A N DI N S T A L L A T I O N G U I D E


Aprivately owned U.K. companywith more than forty years’experience in the industry, Wade isestablished as a leading manufacturerof quality drainage products.Much of the success of the business isattributable to an on-going commitmentto put technology to practical use, togenerate fresh ideas, and to guaranteequality assured manufacturing.This guide presents illustrations andlimited data from a comprehensiverange of products. For detailedinformation please refer to WadeTechnical Handbooks, our CD Rom, orour website.Certification of compliancewith BS EN ISO 9001underlines our commitmentto quality and service.


Contents ACCESS COVERS - GENERAL PURPOSE 23ADAPTORS 24FLOOR GULLIES and ACCESS COVERSASPHALT FLOORS 29DIRECT CONNECTION GRATINGS 19 - 21DIRECT CONNECTION ACCESS COVERS 22 - 23INSTALLATION 4 - 5MISCELLANEOUS GULLIES 31SHOWER GULLIES 32- 33SIDE INLETS 9STAINLESS STEEL GULLIES 6 - 8VARI-LEVEL - BODIES 10 - 13- GRATINGS 14 - 15- ACCESS COVERS 16- ACCESSORIES 17 - 18UNFINISHED FLOORS 30GREASE CONVERTERS 48 - 49LINEAR DRAINAGE 40 - 46MATERIALS 50NON-FREEZE WATER POINTS 47ROOF OUTLETS 34 - 39SEDIMENT / OIL INTERCEPTORS 47SPEC. CODE INDEX 51WATER HAMMER ARRESTORS 47


FLOOR GULLIESInstallation Guidelines1. Where applicable, screw spigot adaptor intothe body outlet using a suitable sealant toensure the joint is watertight.Finished floor level6. Where applicable, dress the membraneover the flange and into the sump of thebody, ensuring that the membrane doesnot restrict the outlet; bolt the membraneclamping collar to the body - certain collarsare reversible to increase height adjustability.Note 1: If a G series body is being usedwithout a membrane, ensure that membraneclamping collar securing holes on top face ofbody are sealed.Note 2: In some cases the membraneclamping collar serves to connect the gratingor cover to the body, so it must be fitted evenwhere a membrane is not used.2. Measure the distance between the topof the connecting pipework and finishedfloor level.3. Check that this distance will enable thecomplete gully (with extensions, if applicable)to be installed with the top face of thegrating or cover flush and level with the finishedfloor.Note: Where a damp-proof membrane isused, the body must be installed with thetop of the flange at or below membranelevel.7. Fit grating, cover, or funnel, withextensions,frame or collar as applicable;set top face flush and level with thefinished floor using height adjustabilityfeatures. Use a suitable sealant on allthreaded joints to ensure a watertightassembly.MembraneLevel4. Connect body (with spigot adaptor if applicable)to pipework.5. Infill as required.8. Infill or lay floor screed and apply final floorfinish (e.g. tiles, marble, paviors, terrazzo)around the grating or cover.Note: Installation of gratings and covers foruse with sheet floor covering, such as vinyl, isincluded in a separate brochure.4


FLOOR GULLIESTypical InstallationsFINISHED FLOORSDAMP PROOF MEMBRANEFINISHED FLOORFLOOR SCREEDDAMP PROOF MEMBRANEFINISHED FLOORFLOOR SCREEDGRATINGFILTERBUCKET(Optional)L24 SERIESGRATINGCONTOUREDCHANNEL TILEDAMP PROOFMEMBRANESTRAINER(OPTIONAL)MEMBRANECLAMPINGCOLLARBODYFLOORSCREEDBELL TRAPSTRUCTURALSLABSPIGOT ADAPTOR(Select separately)STRUCTURALSLABOPTIONALSIDE INLETSTRUCTURALVARI-LEVEL ADAPTOROR BODYSLAB(G SERIES SHOWN)Stainless Steel Gully(See pages 6 to 8)Vari-Level, Non-Trapped.(See pages 10 to 11 and 14 to 16)Vari-Level, Trapped, with ContouredGrating (See pages 12 to 16)FINISHED FLOORMEMBRANEGRATING / COVERMEMBRANECLAMPINGCOLLARFINISHED FLOORSECURED FLATGRATINGMEMBRANECLAMPINGCOLLARSHEET FLOORINGCLAMPING COLLARFLOOR COVERINGGRATING / COVERBODYBODYOPTIONALSTRUCTURALSLABSPIGOT ADAPTORREMOVABLEBOTTLE TRAPSTRUCTURALSLABSPIGOT ADAPTOR(SELECTSEPARATELY)SIDE INLETBODYTIMBERSUPPORTTIMBERPACKINGVari-Level Trapped (with removableBottle Trap) with Bituminous Membrane(See pages 11,14 to 16 and 17)Uni-Level with Asphalt or CompositionFloor (See page 29)Vari-Level with Sheet Floor Coveringin a Wooden Floor (See pages 12 to 16)UNFINISHED FLOORSFLOOR DAMP PROOF MEMBRANEFLOOR SCREED GRATINGFLOOR DAMP PROOF MEMBRANEFLOOR SCREEDGRATINGFLOORFLOOR SCREEDGRATINGDAMP PROOFMEMBRANEMEMBRANECLAMPINGCOLLARBODYMEMBRANECLAMPING COLLARBODYMEMBRANECLAMPING COLLARBODYSPIGOT ADAPTOR(Select separately)STRUCTURALSLABSPIGOT ADAPTOR(Select separately)STRUCTURALSLABSPIGOT ADAPTOR(Select separately)STRUCTURALSLABMulti-Level (See page 30)Multi-Level (See page 30) Multi-Level (See page 30)5


STAINLESS STEEL GULLIES FOR FINISHED FLOORSBody Assemblies( For use with gratings shown opposite )‘P’TRAPPED - 60mm Seal350 Dia150 Sq400 Dia200 Sq193Max260Max221Max.305MaxQ23/30 body assy. with membraneclamping collar and Q42/32 grating.Spec. Outlet GratingCode DepthQ21/30 75 O.D. 30Q21/40 75 O.D. 40Spec. Outlet GratingCodeDepthQ23/30 100 30Q23/40 100 40140200 Sq225Optional sideinlets (4" max.)150300 Sq300Bolt-onFunnel: U511Filter Bucket(Code B)Spec. Outlet GratingCode DepthQ27/30 100 30Q27/40 100 40Spec. Outlet Grating TrapCode DepthQ12/30 100 30 PQ12/40 100 40 PQ13/30 100 30 QQ13/40 100 40 QStrainer(Code S)TrapSee page 9 for details of side inlets6


STAINLESS STEEL GULLIES FOR FINISHED FLOORSBody Assemblies, Gratings.BELL TRAPPED - 60mm Seal350 Dia150 Sq400 Dia200 Sq200 SqFilter Bucket(Code B)Bolt-onFunnel:U511360Max400Max325Strainer(Code S)Bell TrapSpec. Outlet GratingCode DepthQ22/30 75 O.D. 30Q22/40 75 O.D. 40Spec. Outlet GratingCode DepthQ24/30 100 30Q24/40 100 40Spec. Outlet GratingCode DepthQ28/30 100 30Q28/40 100 40Optional sideinlets (4" max.)300 Sq.160Filter Bucket(Code B)300 Sq.585325Bolt-onFunnel:U511Bell TrapSpec. Outlet GratingCodeDepthQ14/30 100 30Q14/40 100 40Q14/36 150 30Q14/46 150 40Spec. Outlet GratingCodeDepthQ10/30 100 30Q10/40 100 40Q10/36 150 30Q10/46 150 40STAINLESS STEEL GRATINGS ( For use with body assemblies shown above and opposite )Anti-Slip Mesh Smooth Mesh Smooth Perforated Bar GratingSpec. Size Depth/ Spec. Size Depth/ Spec. Size Depth Spec. Size Depth/Code Sq. Load Bar Code Sq. Load Bar Code Sq.Code Sq. Load BarQ4132 150 30/2Q4143 150 40/3Q4232 200 30/2Q4243 200 40/3Q4332 300 30/2Q4343 300 40/3Q5132 150 30/2Q5143 150 40/3Q5232 200 30/2Q5243 200 40/3Q5332 300 30/2Q5343 300 40/3Q6130 150 30Q6230 200 30Q7135 150 30/5Q7145 150 40/5Q7235 200 30/5Q7245 200 40/5Q7335 300 30/5Q7345 300 40/5StreamlineSpec. Size Depth/Code Sq. Load BarQ9233 200 30 / 3Q9333 300 30 / 3NOTE : Please ensure that SIZE and DEPTH of the selected gratingmatch the selected body assembly.7


STAINLESS STEEL GULLIES FOR SHEET FLOOR COVERINGBody Assemblies(For use with 300 Sq. gratings shown on page 7)BELL TRAPPED - 60mm Seal325 Sq.160325 Sq.325585OptionalSideInletsFilter Bucket(Code B)Spec. Outlet GratingCodeDepthQ14/30V 100 30Q14/40V 100 40Q14/36V 150 30Q14/46V 150 40Spec. Outlet GratingCodeDepthQ10/30V 100 30Q10/40V 100 40Q10/36V 150 30Q10/46V 150 40Bolt-onFunnel:U511Bell Trap‘P’ TRAPPED - 60mm SealOptionalSide Inlets325 Sq.Filter Bucket(Code B)150300Bolt-onFunnel: U511Spec. Outlet Grating TrapCodeDepthQ12/30V 100 30 PQ12/40V 100 40 PQ13/30V 150 30 QQ13/40V 150 40 Q8


FLOOR GULLIESSide InletsFor typical installation illustrations, see pages 5 and 25.Side inlets in a gully permit the underfloor connection of pipes fromfixtures such as sinks and wash basins, from drainage channels andfrom other gullies.Side inlets in Wade trapped gullies are located completely abovethe water level, except in G102, H102 and GD Series where theinlets are partially below the water level.The illustrations represent typical gully bodies, VIEWED FROMABOVE, and show the SPEC. CODES for all possible combinationsof LOCATIONS.Side inlets in cast iron gully bodies are optional extras which unlessotherwise requested, will be supplied as BSP female threads(specify thread size); stainless steel bodies have BSP femalethreads up to 2"; above 2", spigot side inlets are supplied to suit BS416 pipework.GP11 series plastic gully bodies have 3 side inlets moulded in thatwill accept 50mm plastic pipework; these inlets are usable byremoving knock-outs from the body on site.Denotes sideinlet locations.Denotes outletposition (whereapplicable).Gully Bodies with Vertical Outlet1A 2A 2B 3A 4AGully Bodies with ‘P’ or ‘S’ Trapped Outlet1A 1B 1C 2A 2B 2C 3AGully Bodies with Horizontal Outlet1A 1B 1C 1D2A 2B 2C 2D 2E 2F3A 3B 3C 3D4ATo Specify / OrderQuote the Spec.Code for the selected BODY, withsuffix ‘I’, and the LOCATION and SIZE of each inlet.e.g. G304 body with 2 side inlets tapped 1.5" BSP,in locations per illustration 2B.Specify: G304 I - 2B x 1.5" BSP9


VARI-LEVEL NON-TRAPPED BODIES (CAST IRON)(For use with Vari-Level threaded gratings / covers shown on pages 14-16, 29 and 31)185 Dia.200 Dia.118115(C3)75(C2)C204 BodySpec. Outlet PipeworkCode Size SystemB102 50 BS 416 / DIN 19522B103 75 BS 416B104 100 BS 416 / Din 19522 / PlasticB202 2"BSP ●B203 3"BSP ●Spec. Outlet PipeworkCode Size SystemC202 2"BSP ●C203 3"BSP ●C204 4"BSP ●C343 82 PlasticC344 110 PlasticC363 75 BS437C364 100 BS437C393 75 BS416C394 100 BS416265 Dia.Deep Sump200 Dia.265 Dia.240135115C504 Body illustratedwith optional side inletsee page 9 for details.Optional side inlets - max.2" BSPSpec.CodeC502C503C504OutletSize2"BSP3"BSP4"BSPSpec.CodeD204D206OutletSize4"BSP6"BSPOptional side inlets - max. 4" BSPSpec.OutletCodeSizeD4044"BSPD4066"BSP265 Dia.188 Dia.265 Dia.162200’B’D604 Body45° Outlet 45° Outlet Horizontal OutletSpec.OutletSpec.OutletSpec. Pipework BCodeSizeCodeSizeCode SystemB5044"BSPD6044"BSPD702 2"BSP 86D703 3"BSP 73D704 4"BSP 83Note:C and D Series bodies are supplied with membraneclamping collar, which is optional on B Series bodies10


VARI-LEVEL NON-TRAPPED BODIES (CAST IRON)(For use with Vari-Level threaded gratings / covers shown on pages 14-16, 29 and 31.)’A’265 Dia.Horizontal OutletOptional Side Inlets - max.4" BSP(See page 9 for details)Spec. Outlet ACode SizeD802 2"BSP 280D803 3"BSP 272D804 4"BSP 260D804 BodyD8 Series bodies aresupplied with MembraneClamping CollarVari-Level Non-Trapped Bodies (Cast Iron) for use with Bituminous Membrane( For use with Vari-Level threaded gratings / covers shown on pages 14-16, 29 and 31.)Typical Gully AssemblyD1109 body with membraneclamping collar and K2103nickel bronze grating305 Dia.305 Dia.305 Dia.’A’’B’90Threaded OutletSpec.OutletCodeSizeD10022"BSPD10033"BSPD10044"BSPSpigot OutletSpec. Outlet ACode SizeD1108 75mm BS 416 165D1109 100 mm BS 416 190Horizontal OutletSpec. Outlet BCode SizeD1207 2"BSP 80D1208 3"BSP 67D1209 4"BSP 117D Series bodies are supplied with Membrane Clamping Collar.ConnectionsBodies with spigot outlet are for direct connection to pipework,versions with threaded outlet are for connection to pipework bymeans of a spigot adaptor shown on page 24.11


VARI-LEVEL TRAPPED BODIES (CAST IRON)(For use with Vari-Level threaded gratings / covers shown on pages 14 - 16, 29 and 31)‘P’ TRAPPED - 50 mm seal’E’’E’’B’’B’’A’’A’G303 body illustrated withoptional side inletsOptional side inlets - max.2" BSPSpec. Outlet A E BCode Size*G102 2"BSP 142 140 60Optional side inlets - max.2" BSPSpec. Outlet A E BCode SizeG202 2"BSP 170 185 85G203 3"BSP 205 190 96G303 75mm 170 185 80G304 100mm 205 190 92G804 100mm 205 131 102G804 Body‘S’ TRAPPED - 50 mm sealG604 Body’A’’E’Optional side inlets - max.2" BSPSpec. Outlet A E BCode SizeG502 2"BSP 170 145 150G503 3"BSP 205 156 165G603 75mm 170 145 150G604 100mm 205 155 165G1004 100mm 205 37 205’B’OptionsAll cast iron trapped bodiesexcept H304 have facility foroptional side inlets, see page 9for details. Membrane clampingcollar is supplied with GC andGD Series and is optional onother bodies except H304.ConnectionsBodies with spigot outlet are fordirect connection to pipework,versions with threaded outlet arefor connection to pipework bymeans of a spigot adaptor shownon page 24.G1004 Body‘P’ TRAPPED - 100 mm seal’E’'E'’B’'B'’A’'A'H204 Body* Denotes 3" throatOptional side inlets (H1= max.11 /2" BSP)(H2= max. 2" BSP)Spec. Outlet A E BCode Size*H102 2"BSP 250 161 54H203 3"BSP 345 225 76H204 4"BSP 345 225 76Spec. Outlet A E BCode SizeH304 4"BSP 379 250 9012


VARI-LEVEL TRAPPED BODIES - CAST IRON(For use with Vari-Level threaded gratings / covers shown on pages 14-16, 29 and 31)‘P’ TRAPPED - with rodding access- 100 mm sealJ204 Body’A’’B’’D’’C’Optional side inlets - max.2" BSPSpec. Outlet A B C DCode SizeJ204 4”BSP 345 405 x 225 76 178Close proximity of grating andaccess cover prevents theadjacent use of widest versions.OptionsAll cast iron trapped bodiesexcept H304 have facility foroptional side inlets, see page 9for details. Membrane clampingcollar is supplied with GC andGD Series and is optional onother bodies except H304.ConnectionsBodies with spigot outlet are fordirect connection to pipework,versions with threaded outlet arefor connection to pipework bymeans of a spigot adaptor shownon page 24.BELL TRAPPED - 50mm sealwith full bore rodding access265 Dia.TRAPPED - 50mm sealFor use in low volume drainage applications200 Dia.304280GD144 Body illustrated withoptional side inlet. (Note:Side inlets up to 2" arecompletely above water level,over 2" are partially below).Optional side inlets - max.4" BSPSpec. Outlet PipeworkCode Size SystemBS 416 / DIN 19522 /GD144 100 {Plastic 110mmGD164 100 BS 437RemovableBottle TrapOptional side inlets - max.2" BSPSpec. Outlet PipeworkCode Size SystemGC144 100 {BS 416 / DIN 19522 /Plastic 110mmVARI-LEVEL TRAPPED BODIES - PLASTIC220 Dia.187 Dia.220 Dia.7110450105(Invert)50 Dia.1571035020213450mm Seal 50mm Seal 50mm Seal and optional side inletsSpec. Outlet PipeworkCode Size SystemGP312 50 PlasticSpec. Outlet PipeworkCode Size SystemGP614 110/50 PlasticSpec. Outlet PipeworkCode Size SystemGP1104 110 PlasticNote:All bodies on this page are for use with gratings / covers with 4" throat, (not ✱ K2801, K2901, K3001, K32 orgratings with option suffix ‘V’) except J204 which may also be used with 3" versions. (if used with U1101reducing bush - see p.17). ✱ K2801 may be used with GP312 and GP614.13


VARI-LEVEL GRATINGS For use with bodies shown on pages 10 - 13CAST IRON - BS EN 1561 - sherardized, matt finishCircular gratingSpec. Dia.CodeK2103 CI 155Suitable for service and parkingareas, plant rooms etc.Spec. Dia.CodeK2501 176Spec.CodeL2501 CISize150 sq.Spec.CodeL2601Size150 sq.Decorative floral patternSuitable for service and parkingareas, plant rooms etc.NICKEL BRONZE - BS1400 - satin finishCircular gratingSpec. Dia.CodeK2101 135✱K2102 135K2103 152Indirect waste connectorSpec. Dia.CodeK2201 176For use with sheet floorcovering such as vinyl.Spec. Dia.Code✱K2301 142K2302 176K2303 230Spec. Dia.CodeK2401 152Spec. Dia.CodeK3001 114Spec. Dia.CodeK3101 135For use with trowel appliedcomposition flooring.4mm flange depth.For security areas.Cover screws downto permit drainage.Reduces risk of blockagesin channels. Removabledome protudes 30mm176 dia.To take multiple indirectwaste pipes; with peripheralgratingSpec. Size above FFLCode L W <strong>HK</strong>2601 224 85 99176 dia.To take single indirectwaste pipe; with peripheral gratingSpec. Size above FFLCode Dia. <strong>HK</strong>2701 108 96150 dia.To take single indirectwaste pipe; with peripheralcover and vermin guard.Spec. Size above FFLCode Dia. <strong>HK</strong>3301 101 101150 diaTo take multiple indirectwaste pipes; with peripheralcoveand vermin guard.Spec. Size above FFLCode L W <strong>HK</strong>3302 225 85 96176 dia. For use with sheet floor covering such asvinyl. With peripheral cover and vermin guard.Spec. Size above FFLCode Dia. <strong>HK</strong>3401 101 101✱ Denotes 3" throat (all others 4")Spec. Size above FFLCode L W <strong>HK</strong>3402 224 85 99150 sq.To take single indirectwaste pipe; with peripheralcover and vermin guard.Spec. Size above FFLCode Dia. HL2801 101 101150 sq.To take multiple indirectwaste pipes; with peripheralcover and vermin guard.Spec. Size above FFLCode L W HL2803 225 85 9614


VARI-LEVEL GRATINGS For use with bodies shown on pages 10 - 13NICKEL BRONZE - BS1400 - satin finishStandard square grating Rectangular Square framed grating Johnson 4200Spec. SizeSpec. SizeSpec. SizeSpec. SizeCode✱L2101 101 sq.Code✱L2201 102 x 204CodeL2301 150 sq.Code✱L2402 115 sq.L2102 135 sq.L2202 125 x 430L2103 150 sq.L2104 201 sq.Gail 4420 Pilkington / Wooliscroft 2302 Platt 2300 Ruabon KeramicSpec. Size Spec. SizeSpec. Size Spec. SizeSpec. SizeCodeL2403 150 x 240Code✱L2404 150 sq.CodeL2406 150 sq.Code✱L2407 150 sq.CodeL2408 150 sq.Langley / Buchtal4420 / 54420 Decorative floral pattern Hinged gratingSpec.Code✱L2409Size150 sq.Spec.CodeL2501Size150 sq.Spec.CodeL3001Size161 sq.Grating concealed by solid hinged cover.L5401 version has sealed cover.Spec. SizeCodeL5301 150 sq.L5401 150 sq.STAINLESS STEEL - Grade 304 - satin finishWith peripheral slot for use withsheet floor covering such as vinyl.Spec. Dia.CodeK1807 176Circular gratingSpec. Dia.CodeK2106 152For use with sheet floorcovering such as vinyl.Spec. Dia.CodeK2307 176For use with trowel applied compositionflooring. 6mm flange depthSpec. Dia.CodeK2407 152Flanged with peripheralslot. Self securingSpec. Dia.CodeK2801 140Security area drainage Square grating Streamline heel-proofreverse wedge profileSpec. Dia.Spec. SizeSpec. SizeCodeCodeCodeK2901 114✱L2105 101 sq.L2901 150 sq.L2106 150 sq.L2902 200 sq.Square perforated gratingSpec. SizeCodeL3101 150 sq.L3102 200 sq.Hinged cover with circularnon-secured grating insideSpec. SizeCodeL5307 150 sq.176 dia.Condensate funnel with verminguard, for use with sheet floor coveringSpec. Size above FFLCode Dia. <strong>HK</strong>3407 101 101150 sq.Condensatefunnel with vermin guardSpec. Size above FFLCode Dia. HL2701 114 100✱ Denotes 3" throat (all others 4")15


VARI-LEVEL ACCESS COVERS For use with bodies shown on pages 10 -13DUCTILE IRON - BS EN 1563 and 1564 - sherardized, matt finish‘SuperSeal’(double sealed)Spec. Dia.CodeK5801 176‘SuperSeal’(double sealed)Spec. SizeCodeL5701 150 Sq.NICKEL BRONZE - BS1400 - satin finishGasketed, for use with sheetfloor covering, such as vinylSpec. Dia.Code✱K5101 142K5102 176K5103 250GasketedSpec. Dia.Code✱K5201 135K5202 135K5203 152Gasketed - for use with trowelapplied composition flooring.4mm flange depth.Spec. Dia.CodeK5301 152Plug with ‘O’ ring seal foruse in plunge & foot baths.Spec. Dia.CodeK5401 155‘SuperSeal’(double sealed)Spec. Dia.CodeK5501 152‘SuperSeal’ (double sealed)For use with sheet floorcovering, such as vinyl.Spec. Dia.CodeK5601 176‘SuperSeal’ (double sealed)Recessed for flooring material.Spec. Dia.CodeK5701 152GasketedSpec. SizeCodeL5101 135 Sq.GasketedSpec. SizeCodeL5103 160 Sq.Hinged cover in squareframe. (unsealed)Spec. SizeCodeL5201 150 Sq.Hinged cover with grating inside.L5401 version has sealed cover.Spec. SizeCodeL5301 150 Sq.L5401 150 Sq.‘SuperSeal’(double sealed)Spec. SizeCodeL5501 150 Sq.SuperSeal(double sealed)Spec. SizeCodeL5601 150 Sq.STAINLESS STEEL - GRADE 304 - satin finishFor use with sheet floorcovering, such as vinyl (unsealed)Spec. Dia.CodeK5107 176Gasketed - for use with trowelGasketedapplied composition flooring.Spec. Dia.6mm flange depth.CodeK5206 152 Spec. Dia.CodeK5307 152‘SuperSeal’(double sealed)Spec. Dia.CodeK5507 152‘SuperSeal’ (double sealed)for use with sheet floorcovering, such as vinylSpec. Dia.CodeK5607 176Hinged cover with a circularnon-secured grating inside.(unsealed)Spec. SizeCodeL5307 150 Sq.‘SuperSeal’(double sealed)Spec. SizeCodeL5507 150 Sq.‘SuperSeal’ (double sealed)Recessed for flooring material.Spec. SizeCodeL5807 150 Sq.16✱ Denotes 3" throat (all others 4")


VARI-LEVEL ACCESSORIES For use with Vari-Level Gratings and Access CoversBOLT-ON FUNNELSPORTABLE FUNNELStainlessSteelSpec. SizeCode Dia. HU501 N/Bronze 101 101U502 Cast iron 101 101U511 S/Steel 114 100Spec.SizeCode L W HU601 N/Bronze 225 85 96U602 Cast iron 225 85 96Spec. SizeCode L W HU1202 200 200 250BACKWATER VALVEFILTER BUCKET - Nylon 6Used to intercept debris, valuables etc.REMOVABLE BOTTLETRAP (50mm Seal)Spec. Throat Dia.CodeU703 3"For use with Vari-Levelgrating/cover, 4" throatversion, add suffix “V” tograting Spec. Code.(Not for use with GC, GDor GP Series bodies)NOTE: A filter bucketcannot be fitted if abackwater valve is used.UP701UP702To fit inside gratings with 4" throat.(Not K28, K29 or K30).Typical installation is shown on page 5.Deep version for use with Vari-Level gratings withbodies C5, D4, and D8, adaptors T702, T901 andextensions U1 series.U1404To fit inside grating or bodywith 4" throat / outlet.Typical installation isshown on page 5.GRATING EXTENSION - Cast Iron130 Dia.GULLY ADAPTORS - To connect Vari-Levelgratings/ covers to clay or PVC bodies150 mm sq.REDUCING BUSHSpec. Thread HeightCode Female MaleU101 3" 3" 127U102 4" 4" 60U103 4" 4" 100U104 4" 4" 152U201 4" 3" 115U208∆ 4" ● 25UP104 ✱ 4" 4" 152T1302 For use with 3" throat Grating/CoverT1301 For use with 4" throat Grating/Cover188 mm dia.T1402T1401WeepholeFor use with 3" throat Grating/CoverFor use with 4" throat Grating/CoverTo enable 3" throatU1101gratings/covers to beused in Vari-Level bodies / adaptorswith 4" inlet.Note: Height of grating / cover willbe increased by 15mm min./ 27mmmax.✱ Plastic (ABS) version∆ See T1401 for illustration17


VARI-LEVEL ACCESSORIESFor use with Vari-Level Gratings, Access Covers and BodiesADAPTORS TO PIPEWORK: Vari-Level Gratings and Access Covers, when used without a body, may beconnected to pipework by means of a cast iron adaptor, as shown in the following table.Adaptors for use with Vari-Level Gratingsand Access Covers with 3" throat.Spec. Pipework OverallCode System LengthT701 Plastic 82mm O.D. 127T714 Plastic 75mm O.D. 130T712 Plastic 110mm O.D. 115T801 C.I. BS 416 75mm 127T712 C.I. BS 416 100mm 115T701 C.I. DIN 19522 SMU 75mm 127T712 C.I. DIN 19522 100mm 115T911 Clay SuperSleve 100mm 145All made of cast iron, except TP702, plastic (ABS)Adaptors for use with Vari-Level Gratingsand Access Covers with 4" throat.Spec. Pipework OverallCode System LengthT703 Plastic 82mm O.D. 115T704 Plastic 75mm O.D. 115TP702 Plastic 110mm O.D. 152T803 C.I. BS 416 75mm 115T702 C.I. BS 416 100mm 100TP702 C.I. BS 416 100mm 152T703 C.I. DIN 19522 SMU 75mm 115TP702 C.I. DIN 19522 100mm 152T901 Clay SuperSleve 100mm 130INSTALLATION ADAPTORS - For use with G2 - G10 series trapped bodies.245 Dia.300 Dia.U1501 Stainless steel support plate and cast ironmembrane clamp to adapt G2-G10 series bodiesfor installation in a timber deck with tile floor finish.U1601Stainless steel asphalt flange foruse with G2-G10 series bodies.90° SWEPT BENDMalleable ironDEEP SEAL ‘P’ TRAPCast IronCASpec.CodeU1301Thread2" BSP M/FSpec. Inlet / Outlet A CCode Thread SizeU902 2" BSP 234 162U903 3" BSP 318 210U904 4" BSP 379 25018


CAST IRON - BS EN 1561 - sherardized, matt finishDIRECT CONNECTION GRATINGSFor accessories see page 17. Pipework adaptors are shown on page 24.Standard circular gratingSpec. Dia. PipeworkCodeK2193CI 155 4" C.I. + P ✱Decorative floral pattern.Suitable for service and parkingareas, plant rooms etc.K2591 176 4" C.I. + P ✱ L2591CI 150sq. 4" C.I. + P ✱Spec. Dia. Pipework Spec. Dia. PipeworkCodeCodeSuitable for service and parkingareas, plant rooms etc.Spec. Size PipeworkCodeL2691 150 Sq. 4" C.I. + P ✱NICKEL BRONZE - BS1400 - satin finish (see also pages 20-21)With centralsecuring screwSpec. Dia. PipeworkCodeK1941 98 2" BSPSelf securingSpec. Dia. PipeworkCodeK2041 98 2" BSPStandard circular gratingSpec. Dia. PipeworkCodeIndirect waste connectorK2142 135 82mm PlasticSpec. Dia. PipeworkK2191 135 4" C.I. + P ✱ CodeK2192 135 3" BS416K2193 155 4" C.I. + P ✱ K2291 176 4" C.I. + P ✱wasteSpec. Dia. PipeworkSpec. Funnel Size PipeworkFor use with trowel applied For security areas. Covercomposition flooring.Reduces risk of blockagesscrews down to permit176 dia.To take multiple indirectin channels. Removable4mm flange depthdrainage.dome protrudes 30mm. pipes; with peripheral gratingK2791 108 dia.x 96 4" C.I. + P ✱ K3391 101 dia.x 101 4" C.I. + P ✱K3491 101 dia.x 101 4" C.I. + P ✱Spec. Dia. Pipework Spec. Dia. PipeworkSpec. Funnel Size PipeworkK2491 152 4" C.I. + P ✱ K3091 114 4" C.I. + P ✱ K3191 135 4" C.I. + P ✱ K2691 224 x 85 x 99 4" C.I. + P ✱CodeCodeCodeCode176 dia.To take single indirect waste pipe;with peripheral grating.150 dia.To take single (K3391) or multiple (K3392) indirectwaste pipe; with peripheral cover and vermin guard.176 dia.For use with sheet floor covering such as vinyl.With peripheral cover and vermin guard.Spec. Funnel Size Pipework Spec. Funnel Size PipeworkK3392 225 x 85 x 96 4" C.I. + P ✱CodeCodeCode176 dia.For use with sheet floor covering such asvinyl. With peripheral cover and vermin guard.150 dia.To take single indirect waste pipe;with peripheral cover and vermin guard.150 diaTo take multiple indirect waste pipes;with peripheral coveand vermin guard.Spec. Funnel Size Pipework Spec. Funnel Size Pipework Spec. Funnel Size PipeworkK3492 224 dia.x85x99 4" C.I. + P ✱ L2891 101 dia.x101 4" C.I. + P ✱CodeCodeCodeL2892 225 x 85 x 96 4" C.I. + P ✱ 19✱ C.I. + P means Cast Iron BS 416 / DIN 19522 and plastic


NICKEL BRONZE - BS1400 - satin finishDIRECT CONNECTION GRATINGS(For accessories see page 17. Pipework adaptors are shown on page 24.With centralsecuring screwSpec. Size PipeworkCodeL1941 100 Sq. 2" BSPSelf securingSpec. Size PipeworkCodeL2041 100 Sq. 2" BSPStandard squaregratingRectangularSpec. Size Pipework Spec. Size PipeworkL2194 201 Sq. 4" C.I. + P ✱CodeCodeL2141 101 Sq. 82mm Plastic L2241 102 x 204 82mm PlasticL2191 101 Sq. 3" BS416 L2291 102 x 204 3" BS416L2192 135 Sq. 4" C.I. + P ✱ L2292 125 x 430 4" C.I. + P ✱L2193 150 Sq. 4" C.I. + P ✱Square framedgratingSpec. Size PipeworkCodeL2391 150 Sq. 4" C.I. + P ✱Spec. Size Pipework Spec. Size PipeworkGrating concealed by solidDecorative floralhinged cover. L5491 version hasHinged Gratingpattern.sealed cover.Spec. Size PipeworkL2591 150 Sq. 4" C.I. + P ✱ L3091 161 Sq. 4" C.I. + P ✱ L5391 150 Sq. 4" C.I. + P ✱CodeCodeCodeL5491 150 Sq. 4" C.I. + P ✱Spec. Size PipeworkJohnson 4200 Gail 4420 Pilkington / Wooliscroft 2302 Platt 2300Spec. Size Pipework Spec. Size PipeworkSpec. Size PipeworkL2442 115 Sq. 82mm Plastic L2493 150 x 240 4" C.I. + P ✱ L2444 150 Sq. 82mm Plastic L2496 150 Sq. 4" C.I. + P ✱CodeCodeCodeCodeL2492 115 Sq. 3" BS416L2494 150 Sq. 3" BS416RuabonSpec. Size PipeworkCodeL2447 150 Sq. 82mm PlasticL2497 150 Sq. 3" BS416Spec. Size PipeworkLangley BuchtalKeramic4420 / 54420Spec. Size PipeworkL2498 150 Sq. 4" C.I. + P ✱ L2449 150 Sq. 82mm PlasticCodeCodeL2499 150 Sq. 3" BS416C.I. + P ✱ means Cast Iron BS416 / DIN19522 and Plastic20


NICKEL BRONZE - BS1400 - satin finishFor use with sheet floor coveringDIRECT CONNECTION GRATINGSSpec. Dia. PipeworkCodeN111 98 40mm PlasticN112 ✱✱ 98 40mm PlasticSpec. Dia. PipeworkCodeN211 129 40mm PlasticN213 ✱✱ 98 40mm PlasticN215 129 50mm PlasticN217 ✱✱ 129 50mm Plastic✱ C.I. + P means Cast Iron BS 416 / DIN 19522 and Plastic✱✱ Versions with cast iron backnut for use in timber floorsSpec. Dia. PipeworkCodeN301 129 3" BS416N303 ✱✱ 129 82mm PlasticN305 129 75mm PlasticDINSpec. Dia. PipeworkCodeN405 129 4" BS437N410 ✱✱ 129 4" SuperSleveSpec. Dia. PipeworkCodeK2392 176 4" C.I.+P✱STAINLESS STEEL - Grade 304 - satin finishWith peripheral slot for use withsheet floor covering such as vinyl.Spec. Dia. PipeworkCodeK1897 176 4" C.I. + P ✱Circular GratingSpec. Dia. PipeworkCodeK2196 152 4" C.I. + P ✱For use with sheet floorcovering, such as vinylSpec. Dia. PipeworkCodeK2397 176 4" C.I. + P ✱For use with trowel appliedcomposition flooring. 6mmflange depthSpec. Dia. PipeworkCodeK2497 152 4" C.I. + P ✱Flanged with peripheralslot. Self securingSecurity area drainageSquare GratingStreamline heel - proofreverse wedge profileSpec. Dia. PipeworkCodeK2891 140 4" C.I. + P ✱Spec. Dia. PipeworkCodeK2941 114 110 PlasticK2991 114 4" BS416Spec. Size PipeworkCodeL2196 150Sq. 4" C.I. + P ✱Spec. Size PipeworkCodeL2991 150Sq. 4" C.I. + P ✱L2992 200 sq. 4" C.I. + P ✱Square perforated gratingSpec. Size PipeworkCodeL3191 150Sq. 4" C.I. + P ✱L3192 200 Sq. 4" C.I. + P ✱Hinged cover with a circularnon - secured grating insideSpec. Size PipeworkCodeL5397 150Sq. 4" C.I. + P ✱176 dia.Condensate funnel with verminguard, for use with sheet floor coveringSpec. Size above FFLCode Dia. <strong>HK</strong>3497 101 101Condensate funnelwith vermin guardSpec. Size PipeworkCodeL2791 114 Dia.x 100H 4" C.I. + P ✱✱ C.I. + P means Cast Iron BS 416 / DIN 19522 and Plastic21


DIRECT CONNECTION ACCESS COVERSFor accessories see page 17. Pipework adaptors are shown on page 24.DUCTILE IRON - BS EN 1563 + 1564 - sherardized, matt finish (with cast iron frame)‘SuperSeal’ (double sealed)Spec. Dia. PipeworkCodeK5891 176 4"C.I. + P ✱‘SuperSeal’ (double sealed)Spec. Size PipeworkCodeL5791 150Sq. 4"C.I. + P ✱NICKEL BRONZE - BS1400 - satin finishGasketedSpec. Dia. PipeworkCodeK5241 135 82mm PlasticK5291 135 3" BS416K5292 135 4" C.I. + P ✱K5293 152 4" C.I. + P ✱Gasketed - for use with trowelapplied composition flooring.Stainless steel flange 220mm dia.4mm flange depth.Spec. Dia. PipeworkCodeK5391 152 4"C.I. + P ✱Plug with ‘O’ ring sealfor use in plunge andfoot bathsSpec. Dia. PipeworkCodeK5491 155 4"C.I. + P ✱‘SuperSeal’ (double sealed)Spec. Dia. PipeworkCodeK5591 152 4"C.I. + P ✱‘SuperSeal’ (double sealed)Recessed for flooring materialSpec. Dia. PipeworkCodeK5791 152 4"C.I. + P ✱GasketedSpec. Size PipeworkCodeL5191 135Sq. 4"C.I. + P ✱GasketedSpec. Size PipeworkCodeL5193 160Sq. 4"C.I. + P ✱Hinged cover (unsealed)in square frameSpec. Size PipeworkCodeL5291 135Sq. 4"C.I. + P ✱Hinged cover with grating inside.L5391 version is unsealed, L5491version has sealed coverSpec. Size PipeworkCodeL5391 150 Sq. 4" C.I. + P ✱L5491 150 Sq. 4" C.I. + P ✱SuperSeal (double sealed)Spec. Size PipeworkCodeL5591 150 Sq. 4" C.I. + P ✱SuperSeal (double sealed)Spec. Size PipeworkCodeL5691 150 Sq. 4" C.I. + P ✱✱ C.I. + P means Cast Iron BS 416 / DIN 19522 and Plastic22


NICKEL BRONZE - BS1400 - satin finishFor use with sheet floor coveringDIRECT CONNECTION ACCESS COVERSSTAINLESS STEEL - Grade 304 - satin finishGasketed GasketedGasketed ‘SuperSeal’ (Double Sealed)GasketedSpec. Dia. Pipework Spec. Dia. Pipework Spec. Dia. PipeworkCodeCodeCodeN212 129 40mm Plastic N302 129 3" BS 416 N404 129 4" BS 437N214 129 40mm Plastic N304 129 82mm Plastic N409 129 4" SuperSleveN216 129 50mm Plastic N306 129 75mm PlasticN218 129 50mm Plastic(N214 and N218 have backnut included)Spec. Dia. PipeworkCodeK5192 176 4" CI + P✱Spec. Dia. PipeworkCodeK5691 176 4" CI + P✱For use with sheet floorcovering, such as vinyl (unsealed)Spec. Dia. PipeworkCodeK5197 176 4" CI + P ✱GasketedSpec. Dia. PipeworkCodeK5296 152 4" CI + P ✱Gasketed - for use with trowel appliedcomposition flooring.6mm flange depth.Spec. Dia. PipeworkCodeK5397 152 4" CI + P ✱‘SuperSeal’ (double sealed)Spec. Dia. PipeworkCodeK5597 152 4" CI + P ✱‘SuperSeal’ (double sealed) For usewith sheet floor covering, such as vinylHinged cover with a circular nonsecuredgrating insideSpec. Dia. Pipework Spec. Size PipeworkCodeCodeK5697 176 4" CI + P ✱ L5397 150 Sq. 4" C.I. + P ✱✱ C.I. + P means Cast Iron BS 416 / DIN 19522 and Plastic‘SuperSeal’ (double sealed)Spec. Size PipeworkCodeL5597 150 Sq. 4" C.I. + P ✱‘SuperSeal’ (double sealed)Recessed for flooring materialSpec. Size PipeworkCodeL5897 150 Sq. 4" C.I. + P ✱NICKEL BRONZE BS 1400 - Satin FinishACCESS COVERS - GENERAL PURPOSEUnsealed, secured.Spec. Dia.CodeR311 186Unsealed, secured.Spec. SizeCodeR411 178 Sq.R412 229 Sq.Sealed, recessed forflooring material.Spec. Dia.CodeR611 138Sealed, secured, recessedfor flooring material.Spec. SizeCodeR801 205 Sq.ACCESS COVERS FOR FLEXIBLE SHEET FLOOR COVERINGDOUBLE SEALED ACCESS COVERFOR MAN ENTRYStainless Steel clamping frame50mm wide,is only part visiblewhen insalledSealedSpec. Dia.CodeR621 138Spec. Clear OpeningCode SizeR111 450 x 450R112 600 x 450R113 600 x 600R114 750 x 600R115 750 x 750R116 900 x 600Stainless Steel cover.For use in wallSpec. SizeCodeR511 178 Sq.R512 229 Sq.23


ADAPTORSAdaptors and couplings are available to connect Wade products to pipework made by othersT6 Series T1103 T12 Series T1501 T1603Hub adaptor for caulkjoint.Push fit coupling BS416/437to SuperSleveCopper to BS 416. Adaptormust be brazed / soldered tocopper pipe beforeconnecting to BS 416 bymeans of a proprietary coupling.MJ coupling BS 416 toPlasticFROMTOADAPTORSpec.Code kg2" BSP Female 50mm cast iron caulk joint T601 0.63" BSP Female 75mm cast iron caulk joint T602 2.64" BSP Female 100mm cast iron caulk joint T603 3.2100mm BS 416 or BS 437 100mm SuperSleve T1103 0.250mm BS 416 50mm copper T1201 0.475mm BS 416 75mm copper T1202 0.6100mm BS 416 100mm copper T1203 0.7100mm BS 416 100mm plastic T1501 0.375mm BS 416 75mm DIN 19522 Ensign T1603 1.2MJ coupling 75mmBS 416 to EnsignSPIGOT ADAPTORSA comprehensive range of spigot adaptors, shown in the following table, is available to enable gully bodieswith BSP threaded outlet to be connected speedily and effectively to all pipework in general use. To completethe connection a coupling may be required as indicated.Longer spigots, such as required to pass through a slab, can be made in 10mm increments up to 1000mm.To specify/order add suffix “#” and length (mm), eg. T103#250.PIPEWORK BODY SPIGOT ADAPTOR REQUIREDOUTLETCOUPLINGSystem Nom.Dia. BSP Spec. O.D. Length Material Weightmm Code mm mm kgCast Iron BS416 50 2" T101 60 90 Mild Steel, sherardized 0.5 ProprietaryCast Iron BS416 75 3" T102 87 90 Mild Steel, sherardized 0.9 ProprietaryCast Iron BS416 100 4" T103 111 90 Cast Iron 1.2 ProprietaryCast Iron BS416 150 6" T104 162 90 Cast Iron 1.1 ProprietaryCast Iron BS437 100 4" T105 117 90 Cast Iron 1.4 ProprietaryCast Iron BS437 150 6" T106 171 90 Cast Iron 1.8 ProprietaryCast Iron DIN 19522 (Ensign + SMU) 50 2" T101 60 90 Mild Steel, sherardized 0.5 ProprietaryCast Iron DIN 19522 (SMU) 75 3" T108 84 90 Mild Steel, sherardized 0.7 ProprietaryCast Iron DIN 19522 (Ensign) 75 3" T102 87 90 Mild Steel, sherardized 0.9 Wade T1603Cast Iron DIN 19522 (Ensign + SMU) 100 4" T103 111 90 Cast Iron 1.2 ProprietaryCast Iron DIN 19522 (Ensign + SMU) 150 6" T104 162 90 Cast Iron 1.1 ProprietaryPlastic 50 2" T1702 ✱ 54 60 Plastic (ABS) 0.1 NonePlastic 82 3" T301 82 140 Plastic (ABS) 0.2 ProprietaryPlastic 110 4" T1704 ✱ 110 126 Plastic (ABS) 0.2 NonePlastic 160 6" T303 160 166 Plastic (ABS) 0.6 ProprietaryClay (Densleve) 100 4" T401 131 170 Cast Iron 4.0 ProprietaryClay (SuperSleve) 100 4" T501 122 130 Cast Iron 2.8 ProprietaryClay (SuperSleve) 150 6" T502 178 130 Cast Iron 4.6 Proprietary✱ Solvent weld socket24


FLOOR GULLIES AND ACCESS COVERSWade offers a comprehensive range of gullies with versions to suit different kinds of floor andfloor finish, for connection to all pipework in general use, as shown on pages 4 to 33.1. Stainless steel gully with side inlets.2. Super-Seal access cover in a tiled floor.3. Watertight drainage in a vinyl covered timber floor.4. A selection of floor gullies, access covers, andaccessories.213425


ROOF OUTLETSWade offers a range of roof outlets with versions for use with different types of roof construction,as shown on pages 34 to 39.11321. A selection of Roof Outlets and accessories.2. WF105 parapet outlet connected to a WJ104 downspoutnozzle in an installation with a single ply membrane.23. WC224Z roof outlet with WG102 underdeck clamp and WT103spigot, in a warm roof with single membrane.4. WD204 roof outlet in an inverted roof.426


LINEAR DRAINAGEWade offers a range of gratings of stainless steel, nickel bronze, aluminium and cast iron for usein frames or stainless steel channel, as shown pages 40 to 462131. Heavy duty bar gratingdesigned for trolley wheel-loading.Austenitic stainless steel channeland grating meet the highstandards of hygiene demanded intoday's working environments.Channel profile SVF ensureswatertight connection when usedwith flexible sheet floor coveringsuch as vinyl.2. Stainless steel channel with‘Streamline’ stainless steelgrating.3. Typical installation in a vinylcovered floor.A selection of gratings.27


Wade drainage products are installed in and near all kinds ofbuildings, some examples of which are shown below.A.E.L.T.C.C. WimbledonChep Lap Kok Airport,Hong KongDrainage and accessin a vinyl floorA McDonalds RestaurantThe British LibraryDrainage in block pavingAsda Store, RuncornAccess covers in a marble floor28


GULLIES FOR ASPHALT / COMPOSITION FINISHED FLOORSSuitable for areas with an asphalt finish, subject to car and light commercial traffic.UNI-LEVEL NON-TRAPPED GULLIES305 Dia.’A’’A’90WB324 GullyCast iron body with220 dia. sherardizedductile iron gratingVertical threaded outletSpec. OutletCode SizeWB322 2" BSPWB323 3" BSPWB324 4" BSP’B’Horizontal threaded outletSpec. Outlet A BCode SizeWB332 2" BSP 119 145WB333 3" BSP 119 145WB334 4" BSP 183 90235 Dia.(Integral) Spigot outletSpec. Outlet ACode SizeWB303 75mm 165WB304 100m 190’A’WB514 GullyCast iron body with320 sq. sherardizedductile iron grating350 Dia.Vertical threaded outletSpec. Outlet ACode SizeWB514 4" BSP 171WB516 6" BSP 149VARILEVEL AND DIRECT CONNECTION GRATINGS (Sherardized Cast Iron)Vari-Level version is for use with Vari-Level cast iron bodies shown onpages 10 to 13.With stainless steel asphaltmembrane clamp.Spec. Code OverallVari - Level Direct Con. SizeK2501A K2591A 176 dia.Direct connection version is for use without a body and for connectionto 100 mm pipework - Cast iron BS 416 / DIN 19522 or PVC.See page 24 for pipework adaptors.29


GULLIES FOR UNFINISHED FLOORSFor use in unfinished floors such as plant rooms, yards and car parksMULTI-LEVEL NON-TRAPPED GULLIES -For use with Vari-Level bodies D2 - D8 and GD, shown on pages 10 to 13Sher. ductile iron grtg.Spec. OverallCode SizeM101 220 dia.Cast Iron ExtensionSpec. CodeU301Cast Iron Body with hingedsherardized ductile iron grating.( F3 have stainless steel body )Spec. Overall Overall OutletCode Width Height SizeF204 396 x 396 338 max. 4" BSPF206 396 x 396 338 max. 6" BSPF304 450 x 450 357 max. 100mmF306 450 x 450 357 max. 150mmFor use with E Series bodies shown belowSher. ductile iron grtg.Spec. OverallCode SizeM301 280 dia.Sher. ductile iron grtg.Spec. OverallCode SizeM401 270 sq.Cast Iron ExtensionSpec. CodeU401Note:Versions with D, GD and ESeries bodies are suppliedwith a membrane clampingcollar, which is optional on FSeries.See page 9 for details ofside inlets.Cast Iron BodyMedium SumpCast Iron BodyDeep SumpOptional side inlets -Max. 4" BSPSpec. Outlet HeightCode SizeE204 4" BSP 125E206 6" BSP 125Spec. Outlet HeightCode SizeE404 4" BSP 280E406 6" BSP 280OPTION:Filter Bucket - add suffix ‘B’ to the Spec. CodeALSO AVAILABLE: WD2 to WD7 Series, Multi-Level Non-Trapped Gullies - see page 37 for details of roof outletswhich are commonly used as floor gullies.30


MISCELLANEOUS FLOOR GULLIESGUNMETAL GULLIES - For use in metal decksTrappedNon-TrappedFor tile or composition flooringSpec. Outlet Height DiaCode Size Max.P403 75 391 325P404 100 391 325For sheet floor coveringSpec. Outlet Height DiaCode Size Max.P413 75 391 325P414 100 391 325For tile or composition flooringSpec. Outlet Height DiaCode Size Max.P301 75 228 230For sheet floor coveringSpec. Outlet Outlet Height DiaCode Size Con. Max.P501 50 2”BSPT Male 167 190P502 50 Copper 167 190HIGH CAPACITY GULLIES - Non-Trapped unless statedL: 717 x W: 699 x H: 220 L: 295 x W: 295 x H: 289 L: 450 x W: 450 x H: 280 L: 633 x W:220 x H: 405Zinc coated mild steel bodywith sher. cast iron gratingCast iron body with nickel bronzegratingTrapped stainless steel body withhinged sher. ductile iron grating.Trapped cast iron body withnickel bronze grating and nickelSpec. Outlet Spec. Outlet BodySpec. Outletbronze sealed coverCodeCodeFinishCodeSpec. OutletQ105 100mm BS 416Q301 4" BSP LacqueredQ403 100mm BS 416 CodeQ106 150mm BS 416Q302 4" BSP Plastic coatedQ501 100mm BS 437L: 419 x W: 216 x H:118 L: 552 x W: 292 x H:146 L: 410 x W: 295 x H:274 508 Dia. x H: 357 Max.Cast iron body with sher. castiron grating for use in guttersCast iron body with sher. castiron grating for use in guttersCast iron body with stainless steelgrating for use in pools and pitsCast iron body with sher. castiron gratingand trenchesand trenchesSpec. OutletSpec.OutletSpec. Outlet Spec. OutletCodeCodeCodeCodeQ801 100mm with backwater Q1101 225mm BS 437Q6014" BSP Q7024" BSP Q802 150mm } valve BS 437 Q1102 6" BSP FemaleDRAINAGE OF PLANTING AREAS AND ROOF GARDENSPOOL OVERFLOW90° GULLYLDuctile iron grating withperforated stainlesssteel ballast guardSpec. Use withCode BodiesP801 D10 - D12+ length ( Page 11 )104 Dia.x L(Std.pipe) 200 min.Copper dome with PVCstandpipeSpec. Use withCode BodiesP901 Vari- level+ length (Pages 10 - 13)120 Dia. x L( Standpipe )150194 Dia. x H: 40 Stainless steel standpipe forStainless steeluse with Vari-Level bodiesSpec. Membrane Use withCodeBodiesP1001 Sheet or brush on C2-C5P1002 Asphalt D10-D12( Pages 10,11 )Spec.CodeK3201 Without capK3202 With capK3211 For tiles etc.K3212 For vinyl etc.L: 220 x W: 158 x H: 185 max.Cast iron body withnickel bronze gratingSpec. OutletCodeP1402 2” BSPP1403 3” BSPP1404 4” BSP31


GULLY ASSEMBLIES FOR SHEET FLOOR COVERINGFor use in wet bathrooms, kitchen and shower areas decked with sheet floorcovering, such as vinyl of a thickness up to 3.5mm.ABS Plastic body with stainless steel or nickel bronze clamp collar and grating/cover/funnel.‘P’ TRAPPED GULLY - 50mm seal.GV5 Series - 50mm socket outlet.Grating220 Dia.160 Dia.Clamping collar1 - Peripheral Slot 2 - Slotted Grating10450105(Invert)50 Dia.Removabledip tubeRemovablesediment bucketDimensions shown are for GV50073 - Solid Cover 4 - FunnelSpec. Illus. Top Version Load kgCode No. Material RatingClassGV5007 1 Stainless Steel Grating (periph. slot) K3 1.1GV5103 2 Nickel Bronze Grating (slotted) L15 1.5GV5107 2 Stainless Steel Grating (slotted) L15 1.0GV5503 3 Nickel Bronze Solid Cover (gasketed) L15 1.9GV5517 3 Stainless Steel Solid Cover (unsealed) L15 1.2GV5803 4 Nickel Bronze Funnel (tapered) 101 Dia.x 100H n/a 2.4GV5817 4 Stainless Steel Funnel (parallel) 101 Dia.x 100H n/a 1.7GV5823 4 Nickel Bronze Funnel (oval) 224L x 85W x 99H n/a 3.7OPTIONSSuffixH Fitted with allen screws for security applications (not GV5007)I Tapped to provide a direct connection for waste pipes - specify size 1 1 /4", 1 1 /2" or 2" (solid cover versions only)PB Made of polished bronze ( available for nickel bronze versions only)P Polished (GV5817 is polished as standard)FEATURESWatertight - clamping collar provides a water-tight seal betweenthe flooring material and gully even when the grating is removed.Flow rate - (grating and funnel versions) rate in excess of 40l/min; comfortably exceeds the minimum rate of 24 l/min requiredby BS EN 274 for the discharge from a single shower head.Installation - ideally suited for installation in timber or concretefloors where space is limited.Note: The gully must be supported and installed inaccordance with instructions which accompany the product.32


GULLY ASSEMBLIES FOR SHEET FLOOR COVERINGFor use in wet bathrooms, kitchen and shower areas decked with sheet floorcovering, such as vinyl of a thickness up to 3.5mm.ABS Plastic body with stainless steel or nickel bronze clamp collar and grating/cover/funnel.TRAPPED GULLY WITHVERTICAL OUTLET - 50mm seal.GV6 Series - 110mm spigot outlet with 50mm reducer.220 Dia.160 Dia.GratingClamping collar1 - Peripheral Slot 2 - Slotted Grating15710350Removabledip tubeRemovablesediment bucket50 dia.3 - Solid Cover 4 - Funnel110 dia.Dimensions shown are for GV6007Spec. Illus. Top Version Load kgCode No. Material RatingClassGV6007 1 Stainless Steel Grating (periph. slot) K3 1.1GV6103 2 Nickel Bronze Grating (slotted) L15 1.5GV6107 2 Stainless Steel Grating (slotted) L15 1.0GV6503 3 Nickel Bronze Solid Cover (gasketed) L15 1.9GV6517 3 Stainless Steel Solid Cover (unsealed) L15 1.2GV6803 4 Nickel Bronze Funnel (tapered) 101 Dia.x 100H n/a 2.4GV6817 4 Stainless Steel Funnel (parallel) 101 Dia.x 100H n/a 1.7GV6823 4 Nickel Bronze Funnel (oval) 224L x 85W x 99H n/a 3.7OPTIONSSuffixH Fitted with allen screws for security applications (not GV6007)I Tapped to provide a direct connection for waste pipes - specify size 1 1 /4", 1 1 /2" or 2" (solid cover versions only)PB Made of polished bronze ( available for nickel bronze versions only)P Polished (GV6817 is polished as standard)FEATURESWatertight - clamping collar provides a water-tight seal betweenthe flooring material and gully even when the grating is removed.Flow rate - (grating and funnel versions) rate in excess of 40l/min; comfortably exceeds the minimum rate of 24 l/min requiredby BS EN 274 for the discharge from a single shower head.Installation - ideally suited for installation in timber or concretefloors where space is limited.Note: The gully must be supported and installed inaccordance with instructions which accompany the product.33


ROOF OUTLETSInstallation GuidelinesThe design of the layout of roof outlets should be in accordance with the recommendations given in BS EN 12056:3Wade offers a range of roof outlets with versions for use with different types of roof construction (warm, cold, inverted, nofines screed) for installation in different types of deck (concrete, metal, wood) with different types of waterproofingmembrane (mastic asphalt, built-up felt roofing, single ply), as shown on following pages.Cast iron bodies are available with medium sump (3400 series) or deep sump (3100 series) with choice of outlet size andconnection type, with polycarbonate dome or sherardized cast or ductile iron flat grating.Bodies with spigot outlet are for direct connection to pipework; versions with threaded outlet are for connection topipework by means of a spigot adaptor. Roof outlets should be placed at the roof low points to allow efficient flow of waterto the outlets.Note :For versions with bonded insulation jacket add suffix K to the Spec. Code.For versions with integral PVC flange for use with PVC single ply membranes add suffix Z to the Spec. Code.1. Check DimensionsPrior to installation, check height ofcomponents to ensure compatibilitywith roof build-up, making allowancesfor the membrane thickness.2. Fit Spigot, Check OutletWhere applicable, screw spigot intobody, using a suitable sealant to ensurethe joint is watertight.Position body in roof deck and ensureoutlet is accessible for pipeworkconnection.3. Install BodyInstall body such that flange is flushor sub-flush with roof deck. Ensurebody is fixed securely, either bondedor clamped to the deck if not cast-in.Use a suitable sealant on anythreaded joints e.g. extension flange,to ensure a water-tight assembly.Note: Membrane flange level isdetermined by roof build up.4. Dress Membrane and ClampRefer to membrane manufacturer’sinstructions.Prepare flange of body with suitableprimer and apply membrane, dressingover flange and into sump of body.Position membrane clamping collarand secure to body using fixingssupplied.5. Install InsulationInstall any intermediate roof build-up(e.g. insulation) around outlets.6. Fit Grating, Apply FinishFit dome/grating using heightadjustment where applicable to ensuregrating is flush with roof finish.Apply roof finish around grating.34


ROOF OUTLETSTypical InstallationsWARM ROOF ( See page 36 and 39 )MEMBRANE CLAMPINGCOLLARMEMBRANEEXTENSION FLANGEBEARING PAN(OPTIONAL)MEMBRANE CLAMPINGCOLLARADJUSTABLEBEARING PANMEMBRANEINSULATIONINSULATIONROOF DECKROOF DECKBONDED INSULATIONJACKET WITH OR WITHOUTTRACE HEATING (OPTIONAL)UNDERDECK CLAMP(OPTIONAL)OPTIONAL BONDEDINSULATION JACKETWITH OR WITHOUTTRACE HEATINGRAISING TUBEBODYCOLD ROOF ( See page 37 and 39 )MEMBRANESECURED DOMEMEMBRANECLAMPING COLLARSECURED FLATGRATINGMEMBRANECLAMPING COLLARMEMBRANEROOF DECKBODYROOF DECKBODYSPIGOT ADAPTOR(SELECT SEPARATELY)UNDERDECK CLAMP( OPTIONAL )INVERTED ROOF ( See page 37 and 39 )FLAT GRATING SLOTTED COLLAR /MEMBRANE CLAMPINGMEMBRANECOLLARROOF FINISHINSULATIONBODYROOF DECKSPIGOT ADAPTOR(SELECTSEPARATELY)MEMBRANEBODYMEMBRANE CLAMPINGCOLLARGRAVEL GUARDROOF FINISHINSULATIONSCREEDROOF DECKUNDERDECK CLAMP(OPTIONAL)PARAPET OUTLET( See page 38 )DOWNSPOUT NOZZLE( See page 38 )BALCONY OUTLET( See page 38 )MEMBRANEGRATINGBODYDOWNSPOUTNOZZLEGRATINGMEMBRANECLAMPINGCOLLARRAINWATERDOWNNPIPEGRATINGMEMBRANESCREEDMEMBRANEC0NNECTINGSPIGOTBODYBODY35


ROOF OUTLETSFor Warm Roof( Comprising cast iron body with sherardized ductile iron grating, orpolycarbonate dome )3400 Series (Medium Sump)For use with insulation thicknesses between 80mm and 100mm✱For use with insulation thicknesses between 20 and 135mm190 dia.dome220 dia.grating190 dia.dome220 dia.gratingSPIGOT OUTLETTHREADED OUTLETSPIGOT OUTLETTHREADED OUTLETSPIGOT OUTLETTHREADED OUTLETSPIGOT OUTLETTHREADED OUTLETSpec OutletCode SizeWC202 50WC203 75WC204 100SpecCodeWC222WC223WC224OutletSize2" BSP3" BSP4" BSPSpec OutletCode SizeWC302 50WC303 75WC304 100Spec OutletCode SizeWC322 2" BSPWC323 3" BSPWC324 4" BSPSpec OutletCode SizeWC402 50WC403 75WC404 100SpecCodeWC422WC423WC424OutletSize2" BSP3" BSP4" BSPSpec OutletCode SizeWC502 50WC503 75WC504 100Spec OutletCode SizeWC522 2" BSPWC523 3" BSPWC524 4" BSPHORIZ. THREADED OUTLETSpec OutletCode SizeWC232 2" BSPWC233 3" BSPWC234 4" BSPHORIZ. THREADED OUTLETSpec OutletCode SizeWC332 2" BSPWC333 3" BSPWC334 4" BSP ✱ For larger thicknesses of insulation, please contact our Technical Services Dept.3100 Series (Deep Sump) Threaded OutletFor use with insulation thicknesses between 80mm - 115mm190 dia.dome320 sq.grating310 dia.gratingSpecCodeWC644WC646OutletSize4" BSP6" BSPSpecCodeWC744WC746OutletSize4" BSP6" BSPSpecCodeWC1044WC1046OutletSize4" BSP6" BSPFor use with insulation thicknesses between 20 and 135mm190 dia.dome320 sq.grating310 dia.gratingSpecCodeWC814WC816OutletSize4" BSP6" BSPSpecCodeWC914WC916OutletSize4" BSP6" BSPSpecCodeWC1114WC1116OutletSize4" BSP6" BSP36


ROOF OUTLETSFor Cold Roof, Inverted Roof and No Fines Screed( Comprising cast iron body with sherardized ductile iron grating, stainlesssteel grating, or polycarbonate dome )COLD ROOF3400 Series (Medium Sump)190 dia.domeTHREADEDOUTLETSpec OutletCode SizeWB222 2” BSPWB223 3” BSPWB224 4” BSPSPIGOTOUTLETSpec OutletCode SizeWB202 50WB203 75WB204 100HORIZ. THREADEDOUTLETSpec OutletCode SizeWB232 2” BSPWB233 3” BSPWB234 4” BSP220 dia.gratingTHREADEDOUTLETSPIGOTOUTLETSpec Outlet Spec OutletCode Size Code SizeWB322 2” BSP WB302 50WB323 3” BSP WB303 75WB324 4” BSP WB304 100HORIZ. THREADEDOUTLETSpec OutletCode SizeWB332 2” BSPWB333 3” BSPWB334 4” BSP3100 Series (Deep Sump)190 dia.dome320 sq.grating310 dia.gratingTHREADED OUTLET THREADED OUTLET THREADED OUTLETSpec OutletCode SizeWB414 4” BSPWB416 6” BSPSpec OutletCode SizeWB514 4” BSPWB516 6” BSPSpec OutletCode SizeWB614 4" BSPWB616 6" BSPINVERTED ROOF AND NO FINES SCREED3410 Series - (Medium Sump)220 dia.gratingTHREADEDOUTLETSpec OutletCode SizeWD222 2” BSPWD223 3” BSPWD224 4” BSPSPIGOTOUTLETSpec OutletCode SizeWD202 50WD203 75WD204 100HORIZ.THREADEDOUTLETSpec OutletCode SizeWD232 2” BSPWD233 3” BSPWD234 4” BSP224 sq.gratingTHREADED SPIGOTOUTLETOUTLETSpec Outlet Spec OutletCode Size Code SizeWD322 2” BSP WD302 50WD323 3” BSP WD303 75WD324 4” BSP WD304 100HORIZ. THREADEDOUTLETSpec OutletCode SizeWD332 2” BSPWD333 3” BSPWD334 4” BSP3410 Series - (Medium Sump) 3400 Series (Medium Sump)200 sq. stainless steelgrating190 dia. domeTHREADEDOUTLETSPIGOTOUTLETHORIZ. THREADEDOUTLETTHREADEDOUTLETSPIGOTOUTLETHORIZ. THREADEDOUTLETSpec Outlet Spec OutletCode Size Code SizeWD722 2” BSP WD702 50WD723 3” BSP WD703 75WD724 4” BSP WD704 100Spec OutletCode SizeWD732 2” BSPWD733 3” BSPWD734 4” BSPSpec Outlet Spec OutletCode Size Code SizeWD122 2” BSP WD102 50WD123 3” BSP WD103 75WD124 4” BSP WD104 100Spec OutletCode SizeWD132 2” BSPWD133 3” BSPWD134 4” BSP3100 Series - (Deep Sump)220 dia.grating224 sq.grating200 sq.stainless steelgratingTHREADED OUTLETSpec OutletCode SizeWD514 4" BSPWD516 6" BSPTHREADED OUTLETSpec OutletCode SizeWD614 4" BSPWD616 6" BSPTHREADED OUTLETSpec OutletCode SizeWD744 4" BSPWD746 6" BSP37


ROOF OUTLETSParapet and Balcony Outlets, Downspout NozzlesPARAPET OUTLETS - Reversible cast iron bodyWF102 - WF125WF152 - WF155WF162 - WF165WF156WF166WF176Spec Outlet GratingCode SizeWF102 2" BSP Nickel BronzeWF103 3" BSP Nickel BronzeWF104 4" BSP Nickel BronzeWF105 ✱ 4" BSP Nickel BronzeWF112 2" BSP AluminiumWF113 3" BSP AluminiumWF114 4" BSP AluminiumWF115 ✱ 4" BSP AluminiumWF122 2" BSP Cast IronWF123 3" BSP Cast IronWF124 4" BSP Cast IronWF125 ✱ 4" BSP Cast IronWF152 2" BSP AluminiumWF153 3" BSP AluminiumWF154 4" BSP AluminiumWF155 ✱ 4" BSP AluminiumWF156 6" BSP AluminiumWF162 2" BSP AluminiumWF163 3" BSP AluminiumWF164 4" BSP AluminiumWF165 ✱ 4" BSP AluminiumWF166 6" BSP AluminiumWF176 6" BSP Aluminium✱ With PVC body for use with single plymembrane, see centre pages for illustration.DOWNSPOUT NOZZLES - Cast GunmetalBALCONY OUTLETS - Cast IronSpecCodeWJ102WJ103WJ104OutletSize2” BSP3” BSP4” BSPSpecCodeWJ202WJ203OutletSize2” BSP3” BSPSpecCodeWF604OutletSize100mm BS416SpecCodeWF704OutletSize100mm BS41638


ROOF OUTLETSAccessoriesGRAVEL GUARD - Stainless SteelUNDERDECK CLAMP3400 Series 3100 SeriesSpec Height Spec HeightCodeCodeWG406 150WG408 200WH506 150WH508 2003400 Series 3100 SeriesSpec Material Spec MaterialCodeWG102 Mild SteelCodeWH202 Mild SteelWG102SS S/SteelWH202SS S/SteelBEARING PAN - Galv. Mild SteelFILTER BUCKET - Stainless Steel3400 Series 3100 Series 3400 Series 3100 SeriesSpecCodeWG201SpecCodeWH301SpecCodeWG301Spec.CodeWH401CompatiblewithWC6,WC10,WD4WH402 WC7-9,WC11,WB4-6EXTENSION PIECEStainless steel (Inverted roof only)WD2 - WD7 SeriesSpec HeightCodeWG501 96WG502 35BONDED INSULATION JACKETA factory fitted bonded insulation jacket is used to prevent condensation forming on theunderside of a body.To specify/order add suffix “K” to the roof outlet Spec. Code.Trace heating of insulated bodies is available to help prevent blockage by ice or snow; fordetails please contact our Technical Services Dept.SPIGOT ADAPTORSA comprehensive range of spigot adaptors, shown in the following table, is available to enable gullybodies with BSP threaded outlet to be connected speedily and effectively to all pipework in generaluse. To complete the connection a coupling may be required as indicated.Longer spigots, such as required to pass through a slab, can be made in 10mm increments up to1000mm. To specify/order add suffix “#” and length (mm), eg. WT103#250.On request, spigots may also be threaded both ends. For details, please contact our TechnicalServices Dept.PIPEWORK BODY SPIGOT ADAPTOR REQUIREDOUTLETCOUPLINGSystem Nom.Dia. BSP Spec. O.D. Length Material Weightmm Code mm mm kgCast Iron BS416 50 2" WT101 60 170 Mild Steel, sherardized 1.0 ProprietaryCast Iron BS416 75 3" WT102 87 170 Mild Steel, sherardized 1.7 ProprietaryCast Iron BS416 100 4" WT103 111 170 Cast Iron 2.5 ProprietaryCast Iron BS416 150 6" WT104 162 170 Cast Iron 4.0 ProprietaryCast Iron BS437 100 4" WT105 117 170 Cast Iron 2.6 ProprietaryCast Iron BS437 150 6" WT106 171 170 Cast Iron 4.1 ProprietaryCast Iron DIN 19522 (Ensign + SMU) 50 2" WT101 60 170 Mild Steel, sherardized 1.0 ProprietaryCast Iron DIN 19522 (SMU) 75 3" WT108 84 170 Mild Steel, sherardized 1.2 ProprietaryCast Iron DIN 19522 (Ensign) 75 3" WT102 87 170 Mild Steel, sherardized 1.7 Wade T1603Cast Iron DIN 19522 (Ensign + SMU) 100 4" WT103 111 170 Cast Iron 2.5 ProprietaryCast Iron DIN 19522 (Ensign + SMU) 150 6" WT104 162 170 Cast Iron 4.0 ProprietaryPlastic 50 2" T1702 ✱ 54 60 Plastic (ABS) 0.1 NonePlastic 82 3" T301 82 140 Plastic (ABS) 0.2 ProprietaryPlastic 110 4" T1704 ✱ 110 126 Plastic (ABS) 0.2 NonePlastic 160 6" T303 160 166 Plastic (ABS) 0.6 Proprietary✱ Solvent weld socket39


LINEAR DRAINAGEInstallation Guidelines1. Remove any gratings and clamping frames fromchannel.2. Taking care not to twist, turn the channel upsidedown (base uppermost).3. If there is more than one section to the channel,apply silicone sealant to jointing flange faces or fitrubber gaskets if supplied, and securely boltsections together.4. If connecting to a Wade gully, follow the instructionssupplied.8. lf not supplied, provide and insert spacer barsacross channel at approx. 500mm centres. Spacerbars prevent channel being squeezed while backfillis being compacted and must not be removed untilbackfill is set.9. Fix the channel into position by first grouting buildinties and any adjustment legs firmly in place.10. Taking care not to damage show surfaces, placeheavy weights on top of the channel prior topouring backfill to prevent any lift or movement.11. Backfill around the channel ensuring that backfillmaterial flows evenly under and around thechannel such that no voids are formed.5. Taking care not to twist, turn the channel the correctway up and lower it into the trench and into anyinstalled gullies: ensure top edge of channel is flushwith finished floor level, use the adjustment legswhen supplied.6. Bend the build-in ties as necessary.7. Make the pipework joints below the channelNote :After positioning the channel it is recommended thata water test be undertaken to check that height iscorrect, that, where applicable the fall in the channelworks effectively, that there are no leakages from thechannel system and that there are no signs ofdeformation or damage to the channel which mayhave occured during installation. At this stage it maystill be possible for any necessary rectification workto take place.Please consult our Technical Services Dept. if thissituation arises.12. Remove immediately any material which falls intothe channel.13. When backfill is set, remove spacer bars.14. Fit gratings.15. Clean channels and gratings with water and asuitable cleaning agent where necessary. Under nocircumstances use metal scouring pads or wire woolas these will contaminate surfaces.40


LINEAR DRAINAGEInstallation Guidelines contd.DRAINAGE CHANNEL PROFILE SVF-FOR USE WITH FLEXIBLE SHEET FLOORCOVERINGThe following additional notes / procedures apply:Typical Installation in a vinyl covered floor1. Dress floor covering into channel and fix inaccordance with flooring manufacturer's instructions.2. Fit clamping frames and gratings.SUPASLOT CHANNELSThe following additional notes / procedures apply.1. The slot is covered with an adhesive tape to preventdebris falling into the channel during installation. Donot remove the tape until installation is complete.DRAINAGE CHANNELS WITHPERIMETER ANGLE FRAMEThe following additional notes / procedures apply:1. The gap between the outside edge of the channeland the angle frame is covered with an adhesivetape to prevent debris filling up the gap duringinstallation. Do not remove the tape until installationis complete.2. When the channel is installed, lay the floor into theperimeter angle frame.3. Once the floor is set, carefully remove the spacerbars between the angle frame and the channelusing an angle grinder or similar.Note:Do not remove the spacer bars before fitting thechannel, as it would then be impossible to maintainthe position of the frame relative to the channel.4. Thoroughly clean the gap between the channel andangle frame, degrease and fill with a permanentlyelastic expansion joint sealant. If corrosivechemicals are likely to be present, consult sealantmanufacturer on suitability.Typical InstallationGullies with Linear DrainageWade floor gullies, trapped or untrapped can be used withstainless steel drainage channel as illustrated.Details of a comprehensive range of stainless steel, castiron and gunmetal floor gullies are included in pages 4 to 33.With D1004 LD Non-Trapped body.With G304 LD ‘P’ trapped body.With optional tile upstand(SVFT profile shown)41


LINEAR DRAINAGEChannel Gratings( For use with channel shown opposite )Stainless Steel1234567STAINLESS STEEL - Austenitic grade 304STREAMLINESpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSS31140 1 500 80 20 5 410 A 15SS32150 1 500 135 25 5 690 A 15SS32151 1 1000 135 25 5 690 A15SS32350 1 500 135 25 15 890 A 15SS33150 1 500 150 25 5 760 A 15SMOOTH MESHSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSS50322 2 500 123 20 30 x 10 910 A 15SS51422 2 500 135 20 30 x 16 1040 A 15ANTI-SLIP MESHSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSS70222 3 500 123 20 23 Sq. 1000 A 15SS73232 3 500 150 30 23 Sq. 1205 B 125SS73242 3 500 150 40 23 Sq. 1205 B 125SS74232 3 500 200 30 23 Sq. 1620 B 125SS74242 3 500 200 40 23 Sq. 1620 B 125SS75232 3 500 250 30 23 Sq. 2030 A 15SS75242 3 500 250 40 23 Sq. 2030 B 125SS76232 3 500 300 30 23 Sq. 2440 A 15PRESSEDSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSS40230 4 500 43 15 6 30 A 15SS42231 5 1000 135 15 10 305 A 15SS43233 6 1000 150 15 8 315 A15STAINLESS STEEL BAR( Illustration No.7 ) Manufactured to orderNickel Bronze891011121314NICKEL BRONZE - BS 1400 - Satin FinishSTANDARD SLOTSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSN11230 8 500 60 15 10 172 A 15SN11430 9 500 60 15 16 184 A 15SN12220 10 546 118 10 8 365 B 125SN12230 10 663 135 15 8 425 A 15SN13240 11 486 186 19 10 725 A 15SN16330 14 483 300 15 12 1440 B 125FLORALSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSN23930 12 500 150 15 15 max. 475 A 15DECORATIVESpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSN23130 13 500 150 15 4 280 A 15ALUMINIUM - LM 6STANDARD SLOTSpec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSA12220 10 546 118 10 8 365 A 15SA12230 10 663 135 15 8 425 A 15SA16330 14 483 300 15 12 1440 A 1542


LINEAR DRAINAGEChannel Gratings and Channel (Cont.)Cast Iron12345678CAST IRON -SHERARDIZED CAST IRON BS EN 1561Spec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSC11230 1 500 60 15 10 172 B 125SC11430 2 500 60 15 16 sq 184 B 125SC12430 3 308 116 15 16 335 B 125SC12330 4 387 144 12 11 425 B 125SC23930 5 500 150 15 15 max 475 A 15LACQUERED CAST IRON BS EN 1561Spec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSI23930 5 500 150 15 15 max. 475 A 15SI16460 6 610 305 26 16 1240 C 250SHERARDIZED DUCTILE IRON BS EN 1563 + 1564Spec Illust. Length Width Depth Slot Free Area Load RatingCode No. Width cm2 /m ClassSG15350 7 252 252 21 12 1180 C 250SG16250 8 303 303 25 9 970 C 250Stainless Steel Channel - Austenitic grade 304. For use withgratings shown above and opposite.All channel profiles are also available with optional tile upstand(see page 41) . To specify add suffix ‘T’ and provide details.Profile:RFP - Resin floorNot suitable for use with hardsetting flooring compound.(Use profiles RE or NE)NE - Narrow edgeShow edge may also bemanufactured of materials tocomplement grating,e.g. nickel bronze, cast iron etc.RP - RegularRE - Return edgeSE- Support edgeDEA( Visible length at FFL )BFTo Specify / Order Channel with Grating Quote:GRATING Spec CodeCHANNEL PROFILE Spec CodeGENERAL DIMENSIONS in mm (A to E)OUTLET CONNECTION details -(F above - size / type of pipework system)THICKNESS OF FLOOR FINISHSome typical LayoutsCPA - Perimeter angle frameSVF-For use with sheet floorcovering such as vinyl. Min. gratingwidth required is 80 mm.Straight section‘L’ sectionRPV - Profile RP is available witha decorative factory fitted PVCangle edging strip to which sheetfloor covering can be butt weldedat the time of installation; suchchannel is particularly suited toheavy duty applications.‘T’ section‘U’ section43


LINEAR DRAINAGE‘JUBILEE’ and ‘BUDGET’ Modular systems‘JUBILEE’ MODULAR SYSTEMChannel of grade 304 austenitic stainless steel.Gratings of epoxy coated ductile iron.For use in unfinished floors such as in factories, plantrooms and service areas.FEATURESLoad rating of C 250.Security locking deters unauthorised removal of gratings.Modular parts enable forming of short runs, junctions andcorners.250 M 2 drained per single outlet (based on B.R.E. rainfallfigures of 75mm/hr).One outlet recommended for every 20 gratings.Gratings 303 mm sq.To Specify / Order: Each straight section mustbe in multiples of 303mm. After channel layoutis decided select appropriate spec. codes withquantities of each item required.Spec.CodeS4700S4701S4702S4703S4706S4724S4733S4791S4792DescriptionSection with single grating and4” BSP outletSection with single gratingSection with 2 gratingsSection with 3 gratingsSection with 6 gratings‘T’ Section with 4 gratings‘L’ Section with 3 gratingsJointing pieceStop end‘BUDGET’ MODULAR SYSTEMGrade 304 austenitic stainless steelTo Specify / Order: Select channel sections andindicate choice of grating. (suffix ‘5’ or ‘7’)Example:S6004 5 = Section with 4 smooth mesh gratingsS6107 7 = ‘L’ Section with 2 secured anti-slip meshgratingsGeneral purpose product for use in doorways, walkways,kitchens etc. ( Not suitable for barefoot traffic.)FEATURESChannel and gratings of grade 304 austenitic stainlesssteel.Depth of only 55mm.Modular parts easily bolt together to form straight runs.Inclined side walls ensure secure bedding of channel.Choice of vertical or horizontal outlets.Choice of smooth or anti-slip mesh gratings.Gratings, 123 mm wide, may be secured.Spec Descrption LengthCodeS6000 Section with single grating 500and 100mm vertical outletS6001 Section with single grating 500S6002 Section with 2 gratings 1000S6003 Section with 3 gratings 1500S6004 Section with 4 gratings 2000S6005 Section with 5 gratings 2500S6006 Section with 6 gratings 3000S6007 ‘L’ Section with 2 gratingsS6008 ‘T’ Section with 3 gratingsS6097 Height adjustable feet (optional)(4 needed per section)S6098 Stop endS6099 Horizontal outletS61-- Secured grating(SS50322) Smooth mesh grating - add suffix ‘5’(SS70222) Anti-slip grating - add suffix ‘7’44


LINEAR DRAINAGEChannel - ‘SUPASLOT’, Hidden Lift and Dual Level DrainageStainless Steel austenitic grade 304SUPASLOT CHANNELSuitable for large areas with low volumes of waste watersuch as in abattoirs, butcheries, dairies, breweries etc.SLSSLHLFEATURESDepth from 65mm to 180mm with or without fall.Slot width 18mm (5mm on SSL)Suitable for tiled and resin floors.Easily cleaned by directing jet of water along thechannel towards the outlet.Can be combined with Wade gullies and channel gratings.To Specify/ Order, quote :SpecCodeSL, SSL or HL, length of channel, position and diameter of outletHIDDEN CHANNELHidden channels are suited for draining large areas finishedwith block paving and can be designed to accommodate arange of paving thicknesses and flow rate requirements.FEATURESPaving depth from 15mm to 60mmChannel depth below flange from 30mm to 150mm with orwithout fallSlot width 5mm to 18mmEasily cleaned by directing jet of water along the channeltowards the outlet.Can be combined with Wade gullies, recessed accesscovers and channel gratings.Load rating class of B125Dual-Level drainage available - if required add suffix DSDor SSD to Spec. CodeSpec. Code: HCSpec. Code: HCEDesigned for use against a wall.To Specify/ Order, quote :SpecCodeHC or HCE, length of channel, paving depth, channeldepth, slot width, position and diameter of outletsDUAL LEVEL DRAINAGE CHANNELProvides primary drainage at finished floor level plussecondary drainage at membrane level. Suitable forinstallation in pedestrian and light vehicular areas only.Secondary drainage is available with the Channel profilesshown on page 7.To order / specify, quote:GRATING Spec. CodeCHANNEL PROFILE Spec. CodeSECONDARY DRAINAGE :Single - Spec. Code SSDDouble - Spec. Code DSDGENERAL DIMENSIONS in mm.OUTLET CONNECTION detailsMEMBRANE DEPTH from finished floor level45


LINEAR DRAINAGEChannel - Firefighting Lift, Angle Frame and Tree GrilleStainless Steel austenitic grade 304.CHANNEL AND GRATING FORFIREFIGHTING LIFTTo prevent water, such as from a sprinkler, entering a lift well.FEATURESWill deal with flow of 25 l/s in accordance with BS 5588.‘Streamline’,135 mm wide gratings are secured in thechannel leaving a peripheral slot 8 mm wide. Channel hastwo 150 mm outlets in corner locations.To Specify/ Order, quote :SpecCodeS4800 and lengths of channelANGLE FRAMEFor use over pre-formed channels, with gratings shownon pages 42 to 43.FEATURESAngle frame can be custom made to suit variousapplications; sections can be produced to match any ofthe channel profiles shown on page 43.Please contact our Technical Services Dept. for details.TREE GRILLE321For use in shopping precincts or similar areas subject topedestrian traffic.145411992FEATURESGratings of nickel bronze set in frames of stainless steelaustenitic grade 304.8 gratings set in 2 sections allow fitting around an existingtree.Suitable for tree trunks up to 300mm dia.Matches decorative channel grating SN23130.SpecCodeS460446


NON-FREEZE WATER POINTSWall thickness 130mm min.available in 10mm increments533873/4" BSP1 1 /4" BSP Backnut150 x 903/4" BSPConnectionHinged CoverProvides an external water source for plant watering, areacleaning, vehicle wash down and similar activities.The product is designed to be installed with the valve seallocated inside a building, whilst the on/off control mechanismand hose connections are outside; when the valve is turnedoff, water drains out from the unit so that freezing cannotoccur.SpecWall BoxCode Material FinishYA101 + Wall thickness mm Without Wall BoxYA201 “ “ Aluminium White epoxy coatedYA202 “ “ Nickel Bronze SatinYA203 “ “ Gunmetal SatinOption: Locking cover (only on versions with wall box) - Suffix ‘L’The Wade non-freeze water point is a U.K. Water ByelawsScheme Approved Product - Certificate No. 0306007.WATER HAMMER ARRESTORS'A'Maintenance free, mechanical, water hammerarrestors are designed to eliminate water hammer(shockwaves) caused by fast closing valves, such asquick action taps and solenoid valves withinpipework systems (e.g. dishwashers and washingmachines). For sizing information, please contactour Technical Services Dept.Spec ‘A’ ‘B’CodeBSPWSC 500 127 1/2"WSC 750 127 3/4"WSC 1000 178 1"WSC 1250 178 11/4"WSC 1500 229 11/2"WSC 2000 267 2"'B'SEDIMENT INTERCEPTORSSediment Interceptors are used to help prevent blockages wheresolids such as food scraps, hair, plaster, sediment etc. aredischarged into drain lines.Material: Stainless SteelBucket liftinghandle105Fastener2" BSPInlet430390 sq.Sealedremovablecover1252" BSPOutletSedimentbucket orfilter bagSpec Flow rate SolidsCode l / sec. collector5740 0.4 Bucket - stainless steel5750 0.4 Bag - polyesterNote:Minimum clearance above cover of 450mm isrequired for removal of bucket / bagOIL INTERCEPTORSOil Interceptors are installed in drain lines to help prevent the pollution of rivers,streams, drainage systems and water treatment plants.Units are used where spillages of oil or diesel could occur such as garages,transport workshops, diesel re-fuelling and storage areas, and where vehicles orplant are washed down or steam cleaned.Oil Interceptors are not suitable for petrol and volatile liquids.To Specify /OrderSelect the appropriate code from the table and add the required ‘C’ dimension,e.g. for oil interceptor to accept a flow 3.5 l/sec. and having a ‘C’ dimension of250mm. - Specify 5360, “C” dimension = 250mm.Spec Flow rate Inlet / Outlet Length WidthCode l / sec. Size B.S.P. mm mm C D5330 1.9 4" 594 382 To be 3685360 3.8 4" 775 482 specified 432on order*5380 5.7 4" 988 669 419‘C’ dimension is from top of cover to centre of inlet.‘D’ dimension is from bottom of interceptor to centre of inlet.Note:*Minimum ‘C’ dimension available is 150mm, larger dimensionsshould be specified in increments of 10mm.Larger sizes of oil interceptors are available, please contact ourTechnical Services Dept. for details.47


GREASE CONVERTERSA Wade Actimatic Grease Converter provides a NATURAL, safe and environmentally friendly means of PERMANENTLYconverting grease to bio-degradable products.In powder or liquid form, Wade Actimatic is a bacterial product (not enzyme), which maintains a micro-biological culturewithin the grease converter to deal with kitchen effluent.Types of InstallationFLOOR STANDING(Standard and low profile models)FULLY RECESSED IN GROUND FLOOR(Standard invert models)FULLY RECESSED IN GROUND FLOOR(Deep invert models)INSTALLATION GUIDELINESFULLY RECESSED IN INTERMEDIATE FLOOR(Hanger Type)Wade Actimatic Grease Converters are designed to be installed in existing or new kitchens, at restaurants, canteens,hotels, hospitals, etc., and also at commercial or industrial premises where food is cooked, prepared or processed.They are not suitable for use with dedicated chicken rotisserie ovens unless special housekeeping measures aretaken, including the introduction of water.There is no optimum distance between the last fixture and the converter; it is generally accepted that pipework longerthan 8 metres may allow grease to solidify before it reaches the converter.Waste disposal units may discharge into a Grease Converter, but this practice is not advisable because frequentcleaning out will be necessary.Waste from vegetable peelers must be filtered before discharging.Certain cleaning agents (Chlorine, strong caustics, bleach etc.) in concentrated form, have a detrimental effect, andshould not be discharged into a Grease Converter.Installations may require prior approval from the Local Authority Environmental Health Dept.Wade Actimatic Grease Converters satisfy current Building Regulations / Standards in the U.K., and meetrequirements of drainage systems designed in accordance with BS EN 12056 -1: 2000Spigot adaptors for connecting to different types and sizes of pipework are shown on page 24.Note: Do not reduce the stated inlet or outlet size otherwise blockages could occur.INDEPENDENT PRODUCT ASSESSMENT :In 1989 Wade became the first manufacturer of grease converters to be awarded an Agrément Certificate.Since 1990 The Royal Institute of Public Health has annually awarded its Certificate of Hygienic Merit to Wade for theActimatic Grease Converter.48


GREASE CONVERTERSHOW TO SELECT AND SIZE GREASE CONVERTERSTo determine the optimum size of converter to be used, account must be taken of the volume of fixtures discharging into the converter. Use the tablebelow to calculate total volume by entering the quantity of each fixture, multiply by the volume shown and enter as Total Vol.; finally, add up your answers.Type of Fixture Approx. Size Approx. Vol. Qty. Total Vol.(mm) (litres) (litres)Handwash Sink 300 dia. x 180 deep 12Domestic Single Sink 450 x 350 x 200 32Domestic Double Sink (450 x 350 x 200) x 2 64Commercial Sink 600 x 450 x 300 81Double Commercial Sink (600 x 450 x 300) x 2 162Commercial Potwash Sink 760 x 500 x 380 144Tilting Kettle 150Small Dishwasher Outlet pipe 32 dia. 185Medium Dishwasher Outlet pipe 40 dia. 235Large Diswasher Outlet pipe 50 dia. 350Other fixturesTOTAL VOLUME OF FIXTURES (LITRES)2" BSP Vent Pipe Connection(Vent to atmosphere if required)ABGABFC150 Min.C200 min. 140EDED20075‘5000’ Series‘5200’ SeriesAfter selecting the appropriate type of installation, and calculating the total volume of fixtures, select the “Spec.Code” from the table below and add therequired “C” dimension.e.g. for Converter to serve fixtures with a total volume of 325 litres and having a “C” dimension of 400mm, Specify : 5060XT “C” = 400mmType of Max.total vol. of Spec. In/Oulet A B C D E F G RequiredInstallation Fixtures in Ltrs. Code BSP Inches mm mm mm mm mm mm mm slab openingopen 160 5020LR 4 775 482 150 180 330 ● ● ●FLOOR STANDING 160 5022LR 2 775 482 150 180 330 ● ● ●Low profile 290 5032LR 2 988 669 150 180 330 ● ● ●290 5035LR 4 988 669 150 180 330 ● ● ●FLOOR STANDING 210 5030 4 594 382 150 368 518 ● ● ●Standard invert 410 5060 4 775 482 150 432 582 ● ● ●625 5080 4 988 669 150 419 569 ● ● ●FULLY RECESSED 210 5030XT 4 594 382 368 ● ● ● ●GROUND FLOOR 410 5060XT 4 775 482 432 ● ● ● ●Deep invert 625 5080XT 4 988 669 419 ● ● ● ●FULLY RECESSED 1250 5215 6 1516 953 737 ● 482 775 ●GROUND FLOOR 2100 5225 6 1869 1142 940 ● 482 775 ●Deep Invert 2900 5235 6 1996 1270 990 ● 482 775 ●Large capacity 4200 5250 6 2315 1512 1346 ● 482 775 ●FULLY RECESSED 210 5030H 4 594 382 368 ● ● ● 625 x 445INTERMEDIATE FLOOR 410 5060H 4 775 482 432 ● ● ● 805 x 545Hanger Type 625 5080H 4 988 669 419 ● ● ● 1020 x 730}}}}}To be specified on orderFor the hanger types listed, the dimension from finished floor level to theunderside of the hanger frame (normally slab level) is adjustable on sitefrom 35mm min to 75mm max.N.B. In practice fixtures do not all discharge at the full ratesimultaneously. This has been allowed for and the table enables thecorrect grease converter to be selected. In abnormally high or ‘dump’situations contact our Technical Services Dept.AUTOMATIC DOSING SYSTEMA mains powered dispenser unit is available for use with Actimatic Liquid.The unit automatically doses the Converter with diluted Actimatic Liquidonce daily at a time selected by the user.The system, once set, requires only monthly attention to replenish the liquidsupply, and is suitable for use in most new and existing drainage systems.A warning light and audible alarm indicates low level of liquid.To Specify / Order:Spec. Code : ADU Automatic Dosing UnitSpec. Code : AL1 Actimatic Liquid ( 1 ltr.)Options: Wall mounting bracket for storage drum - madeof grade 304 stainless steel with large radiussed cornersto facilitate cleaning - add suffix ‘MB’ to Spec. Code.49


MATERIALSMaterials and finish of Wade products, described below, are selected to provide lasting performance and to blend withsurroundings. The products require the minimum of maintenance, but periodic inspection should be carried out to ensureabsence of matter which could impede drainage. Measures set out below will sustain appearance and prolong service life.STAINLESS STEEL - AUSTENITIC GRADE 304Used for bodies, channels, gratings, funnels, covers, gravel guards, filter buckets and fixings.A corrosion-resistant metal containing significant amounts of nickel snd chromium.Clean with soap and warm water rinse and wipe dry. Gratings may also be cleaned in certain dishwashers.Under no circumstances treat with metal scouring pads, metal scrapers or wire wool as these will contaminate surfaces leaving rust spots.NICKEL BRONZE - BS 1400 Satin finishUsed for gratings, covers and funnels.A cast alloy with a fine grain effect which blends well with most floor finishes. The satin finish is generally maintained by the slight abrasiveaction of passing traffic. In unused areas the material will gradually tarnish. To restore lustre, apply a plain nylon scouring pad (not soapfilled)in the direction of the grain.POLISHED BRONZE - BS 1400Used for gratings, covers and funnels.A cast alloy suited for finished floors where the rich, bronze colour complements the decor. The "mirror" finish is produced by polishing. Ifleft alone polished bronze will gradually tarnish. To restore lustre, use metal polish and buff with a cloth. The mirror finish must not be treatedwith any abrasive cleaning material otherwise the surface will be permanently scratched.DUCTILE IRON - BS EN 1563 + 1564Used only for gratings.A casting with the ductility of steel, yet with more than twice the tensile strength of cast iron. A zinc anti-corrosion coating is applied bygalvanising or sherardizing.CAST ALUMINIUM - LM6Used for parapet and channel gratings.An alloy chosen for its chemical resistance and durability.CAST IRON - BS EN 1561Used for bodies, membrane clamping collars, spigot adaptors and accessories such as extensions.A widely used metal in the drainage industry, its resistance to corrosion permits extended use under extreme conditions. Castings are coatedwith a high grade lacquer paint applied by full immersion dip to provide internal and external surface coverage. Paint will gradually wear offand is replaceable; oxidisation (surface rusting) is a natural process which does not weaken the material.A zinc anti-corrosion coating is applied to certain castings by galvanising or sherardizing.MILD STEELUsed for adjustable bearing pans and raising tubes.A cost effective material to which a zinc anti-corrosion material is applied by galvanising or sherardizing.POLYCARBONATEUsed for roof outlet domesA polycarbonate / ABS blend which offers durability, high impact strength and long term resistance to ultraviolet light.POLYPROPYLENEUsed for the removable trap in stainless steel gullies.PVCUsed for roof outlet body versions for use with PVC single ply membranes.This material enables a waterproof joint to be produced on site.ABSUsed for bodies, dip tubes, extensions and spigot adaptorsA cost effective, fire-resistant material.NYLON 6Used for bottle trap and filter bucketChosen for its toughness and durability.50


INDEXSpec CodePageSpec CodePageADU 49B1 - B5 10C2 - C5 10D2 - D7 10D8 11D10 - D12 11DSD 45E2, E4 30F2, F3 30G1 - G10 12GC1 13GD1 13GP 13GV5-632-33H1 - H3 12HC, HE 45HL 45J2 13K Jacket 39K18 15, 21K19 - K20 19K21 - K22 14, 15, 19, 21K23 14, 15, 21K24 14, 15, 19, 21K25 14, 19, 29K26,K27 14, 19K28,K29 15, 21K30,K31 14, 19K32 31K33 14, 19K34 14, 15, 19, 21K51 - K58 16, 22, 23L19, L20 20L21 14, 15, 19-21L22 14, 15, 19-21L23 15, 20L24 15, 20L25 14, 15, 19, 20L2614, 19L27 15, 21L28 14, 19L29 15, 21L30 15, 20L31 15, 21L51, 52 16, 22L53, L54 15, 16, 20, 22L55 16, 22, 23L56, L57 16, 22L58 16, 23M1 - M4 30N1 21N2 - N4 21, 23NE 43PA 43P3 - P5 31P8 - P10 31P14 31Q1- Q8 31Q10 7Q11 31Q12, Q13 6Q14 7Q21, Q23, Q27 6Q22, Q24, Q28 7Q41- Q93 7R1, R3 - R6, R8 23RE 43RP 43SA 42SC 43SI 43SG 43SL 45SN 42SS 42SSD 45SVF 43S644S47 44S48 46T1 - T624T7 - T9 18T11 - T12 24T13 - T14 17T15 - T17 24TP7 18U1 - U2 17U3 - U4 30U5 - U617U9 18U11 17U13 18U14 17U15 - U1618UP7 17WB2 37WB3 37, 29WB4 37WB5 37, 29WB637WC 36WD 37WF 38WG - WH 39WJ 38WSC 47WT 39YA 473100 36, 37, 393400 36, 37, 393410 37, 395020 - 5250 48, 495330 - 5750 4751


CI/SfBApril 2003CI/SfBJune 2 03CI/SfB(52)May 2 03Information Technology from WadeWade literature is available on CD ROM, accessible on an IBM compatible PCwith a CD ROM drive and Windows 95 or above.The CD also includes WADE-CAD - a selection of drawings in both Autocad andDXF format, accessible on PC or Apple Mac.Our website also contains product information, price list and CAD files.Unicla s EPICUnicla s EPICUnicla s EPICRoofOutletsDrainage Productsfor use with sheet floor coveringLinear DrainageServiceProduct Information and technical advice are available from the Wade Technical Services Department atHalstead, Essex, from Wade Drainage Technical Consultants located throughout the U.K. and from selecteddistributors throughout the world. A computer-aided design service is available free of charge for layouts andassemblies of Wade products.WarrantyThe Company warrants its products to be free from defects in material and workmanship for a period of 12months from the date of delivery.The Company’s obligation under this warranty is limited, at its option, to the repair or replacement, free of charge,or refund of the net invoiced price of any part found to be defective, and which, in the Company’s opinion, hasnot been subject to undue wear and tear, accident, alteration, abuse or misuse. Consequential damages areexpressly disclaimed.Technical advice from Wade International Ltd., whether verbal, in writing or by way of trials, is given in good faithbut without warranty. The application, use and installation of the Company’s products are beyond the control ofthe Company, and the purchaser is solely responsible for ensuring that goods are fit for any particular purpose.In line with the Company’s policy of continual research and development, product specifications and availabilityare subject to change or withdrawal without prior notice.DimensionsIn line with general practice all dimensions shown are nominal.QUALITY BY TRADITIONPERFORMANCE BY DESIGNWADE INTERNATIONAL LTDThird Avenue . HalsteadEssex . CO9 2SX . U.K.Telephone: +44 (0)1787 475151 . Facsimilie: +44 (0)1787 475579e-mail: tech@wadedrainage.co.uk . website: www.wadedrainage.co.uk