12.07.2015 Views

Standard Details for Metal Roofing & Siding - Best Materials

Standard Details for Metal Roofing & Siding - Best Materials

Standard Details for Metal Roofing & Siding - Best Materials

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Post Frame Flashing <strong>Details</strong>ENDLAP1. Apply 3/32” x 1/2” butyl endlap sealant on bottom paneljust below centerline of purlin (see endlap diagram <strong>for</strong>location) on panel #1.2. Apply sidelap sealant on panel #1 and connect to endlapsealant.3. Place panel #2 so it overlaps panel #1, 12” as shown.Install screws per endlap fastening pattern.4. Apply sidelap sealant on panel #2 to connect to sidelapsealant of panel #1.5. Place panel #3 over sidelap of #1 and #2.6. Apply endlap sealant on panel #3.7. Apply sidelap sealant on panel #3 and connect withendlap sealant.8. Place panel #4 over endlap of panel #3. Install screwsper endlap pattern.9. Repeat sequence <strong>for</strong> entire roof.STEP #1STEP #2DOWN SLOPEDOWN SLOPEROOF PANEL2"OVERLAPPINGFROM PURLIN EDGEROOF PANEL2"OVERLAPPINGFROM PURLIN EDGE3 1/2"CONTINUOUS BEAD OF 3/32" x 1/2"BUTYL SEALANT TAPE3 1/2"12" Total Lap6 1/2"10" To SealantFASTENERS @ENDLAP PATTERN6 1/2"PURLINPREVAILING WINDENDLAP TAPE ALIGNWITH PURLIN EDGEINSTALLATION SEQUENCEFOR STRONGRIB, GRANDRIB 3,5V CRIMP, ALU-TWINSIDELAP TAPETHIS EDGE53142SIDELAP TAPETHIS EDGEENDLAP TAPETHIS EDGE42153EAVEOVERHANG1" TO 2"SKIRT BOARD OFTREATED LUMBER ORFOUNDATION OF BLOCK12" TO 18" FROMGROUND LEVEL"L" (IN FEET)WHEN INSTALLING 2 1/2" OR 1 1/4"CORRUGATED ROOFING USEINSTALLATION SEQUENCE AS SHOWNSTART ENDPanelNameAlu-TuffGrandrib 3Prime Rib5V2 1/2" Corrugated1 1/4" CorrugatedAlutwinFabribALLOWABLE PANEL LENGTHS (ft.) ALONGTHE SLOPE FOR 4" RAINFALL PER HOURMinimum2 1/2:122 1/2:122 1/2:122 1/2:122 1/2:122 1/2:122 1/2:122 1/2:12Slope2 1/2:1258583943281637323:1261614145 47 49291639343 1/2:12Notes For Rain-Carrying Tables1. All values based on a 1-hour duration storm of 4"/hr. intensity.2. Values represent the point at which the panel ribs will flood.3. Size and frequency of penetrations can greatly reduce the amount of water removed from a rooof.4. All panel endlaps must be caulked.5. When weather-tightness is crtical, use sealant tape in all sidelaps.64644331174136Roof Slope4:12676745321843385:127373496:1254 58352046417878533821504414

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!