12.07.2015 Views

Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

Hydrometer Sharky 773 Ultrasonic Compact Energy ... - hsa-asia.com

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>APPLICATION❑ Static <strong>com</strong>pact energy meter using ultrasonic technology❑ Highly accurate recording of all billing data in local anddistrict heating and cooling systemsHEAD LOSS DIAGRAMDE-06-MI004-PTB017MEASURING ACCURAnCY TO EN 1434 CLASS 2FEATURES❑ 1st. approval in Europe for ultrasonic meter with dynamicrage of qi/qp 1:250 in class 2(qp 1.5 / 2.5 / 6.0 / 10.0 / 15.0 m 3 /h)❑ MID approval❑ <strong>com</strong>plete dynamic range ≥1:1500❑ Lithium battery (lifetime 12 years, 16 years optional),230 V AC or 24 V AC main supply❑ Patented free-beam principle❑ Improved service-friendly meter design❑ housing up to 190 mm thread and flange (PN 16 / PN 25)❑ Can be used as cooling, heating or <strong>com</strong>bined climaticmeter❑ Temperature range 5-130 °C/150 °C❑ Overload temperature up to 150 °C❑ Swirl-free flow around reflector❑ New construction –> lower pressure loss❑ Robust stainless steel reflector❑ Available in nominal sizesq p 0.6 - 1.0 - 1.5 - 2.5 - 3.5 - 6.0 - 10.0 - 15.0 - 25.0 m 3 /h❑ Measuring accuracy meets the requirements of EN1434class 2 and 3❑ No calming sections necessary in the inlet and/or outlet(standard installation)❑ Insensitiv against magnetite in the liquidSPECIAL FEATURES❑ Power save mode❑ NOWA test capability❑ Remote reading via M-Bus, Radio, RS232 oroptical interface❑ Optional Plug & Play modules❑ Individual tariff functions❑ History memory for 24 months❑ Extensive diagnostic displays❑ HYDRO-SET parametrization software on Windows basisguarantees optimum adaptation to the user’s specific needs


ULTRASonic energy meter 0.6 – 2.5 m3/h<strong>Ultrasonic</strong> <strong>com</strong>pact heat meter SHARKYModel <strong>773</strong>DAtasheet ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>GENERAL❑ Static <strong>com</strong>pact energy meter with fully electronic measurementbased on the ultrasonic principle❑ Storage of volume and energy dataCOMPONENTS❑ <strong>Ultrasonic</strong> volume measuring <strong>com</strong>ponent❑ Integrator with integral hardware and software for measuringflow rate, temperature and energy consumption❑ Temperature sensorsINTEGRATORThe integrator contains all the necessary circuits forrecording the flow rate and temperature and for calculating,logging and displaying the data. The integrator housing canbe mounted directly on the volume measuring <strong>com</strong>ponentor on the wall. The meter can be conveniently read from asingle-line 7-digit display with units and symbols. A pushbuttonprovides user-friendly control of the various displayloops. All failures and faults are recorded automatically andshown on the LC display. To protect the reading data, all therelevant data are saved in a non-volatile memory (EEPROM).This memory saves the measured values, device parametersand types of error at regular intervals.ULTRASONIC VOLUME MEASURING COMPONENTThe ultrasonic technology of the volume measuring <strong>com</strong>ponentpermits very high measuring accuracy and can be usedin the forward or return line. The volume measuring <strong>com</strong>ponentmeets the requirements of EN 1434 / class 2 and 3.The standard cable length between the calculator and thevolume measuring <strong>com</strong>ponent is 1.5 m (5m optional).Supply voltage:❑ Lithium battery 3.0 V DC (12-year life)❑ Lithium battery 3.6 V DC (16-year life) optional❑ Mains unit 230 V AC or 24 V ACTEMPERATURE SENSORSPairs of Pt 100 or Pt 500 temperature sensors (Ø 5.2 mm)with 2-wire leads are used as a standard.INTERFACESSHARKY is equipped as standard with a ZVEI optical interfacewith the M-Bus protocol as per EN 1434. This interface isused, for example, for <strong>com</strong>munication with the HYDRO-SETparameterization software. The meter features 2 slots forthe modules. One slot for the function modules, and one forthe <strong>com</strong>munication modules.The following <strong>com</strong>munication modules are available asoptions:❑ Real Data Radio Module❑ M-Bus module to EN 1434❑ RS 232 moduleThe RS 232 module is a serial interface and permits dataexchange with the heat meter. For this purpose a specialdata cable is necessary (please find order references).The Radio module <strong>com</strong>municates a list of predefined datarecords. This can be edited by HYDRO-SET.PULSE inPUTTwo additional pulse inputs are available. The pulse valueand the unit is configurable for energy, water, gas or electricalmeter by HYDRO-SET. Also two accounting day´s areavailable for both inputs.PULSE OUTPUTThe meter provides levels for two optional external pulseoutputs, which can be freely programmed using theHYDRO-SET software.Possible pulse output values❑ <strong>Energy</strong> (standard setting)❑ Volume (standard setting)❑ Tariff energy 1❑ Tariff energy 2❑ Tariff condition 1, limit switch❑ Tariff condition 2, limit switch❑ <strong>Energy</strong> error❑ Volume errormodule <strong>com</strong>binationsThe following module <strong>com</strong>binations for data transmissionare available ex works or for retrofitting in the field.Function modules:❑ Pulse input module❑ Pulse output moduleCommunication modules:❑ M-Bus or❑ RS 232 or❑ Real Data Radio


DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>ACCESSORIES/SOFTWAREThe HYDRO-SET parametrization software based on theM-Bus is a convenient tool for handling the meter. It runs onWINDOWS® 2000/XP and is used for:❑ taking meter into operation❑ reading out different memories❑ printing out meter logs❑ meter configurationFurther information about the HYDRO-SET software isavailable for free downloading from our website atwww.hydrometer.<strong>com</strong>/Systems/Downloadcenter.html❑ Reading the meter on a certain day.Example: If the day for reading is 01.10, the meter readingis displayed for the period from 01.10 of the previousyear to 30.09 of the current year.❑ Comparison of the last consumption period with the precedingperiodEVENT MEMORYEvents such as changes and faults are stored in a non-volatilememory with a capacity of up to 31 entries. The followingevents are recorded:❑ Checksum error❑ Temperature measurement error❑ <strong>Ultrasonic</strong> echo time measurement errors❑ Start and end of test modeMONTHLY MEMORYSHARKY has a history memory of 24 months. The followingvalues are stored in the EEPROM on the programmed date1 ... 31 via (HYDRO-SET) of the actual month:❑ Date/Time ❑ Volume❑ <strong>Energy</strong> ❑ Error day counter❑ Tariff energy 1 ❑ Maximum monthly flow rate❑ Tariff energy 2 ❑ Maximum monthly power❑ Tariff definition 1 ❑ Date of maximum monthly flow rate❑ Tariff definition 2 ❑ Date of maximum monthly power❑ Impulse input 1 ❑ Impulse input 2Table 1MAX. VALUESThe integrator creates max. values for power and flow ratebased on consumption time, which are stored in the EEPROM.The integration intervals are adjustable to 6, 15, 30 or 60minutes or 24 h. Default setting is 60 minutes.TARIFF FUNCTIONThe integrator offers two optional tariff memories for monitoringplant load states for limit tariffs. Extensive tariffconditions make it possible to adapt the meter individuallyto the required customer-specific applications.Apart from the energy a time-based tariff can also be programmed.The following limit types are possible:(This example applies to the display with 3 decimal places)LOG MEMORYThe log memory is used to store consumption values. Thestorage frequency can be selected from various storageintervals (1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 minutes orthe default setting of 24 hours, see Table 1). The data savedin the log memory can be used for the following analyses:


DAtasheet ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>DISPLAY CONTROLThe readings are displayed on the meter by a 7-digit LCD with units and symbols.LOOP STRUCTUREThe SHARKY-HEAT display has six loops. Some display windows consist of two (to maximum seven) displays that are shownalternately at 4-second intervals.Some pictures in loops can be deactivated separately.Note: For quick visual guidance, the loops in the display are numbered from 1 to 6.The main loop with the current data, e.g. for energy, volume and flow rate, is programmed as default setting.In the standard setting the loop no. 5 (tariff loop) is not activatedOVERVIEW OF LOOPS


DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>INFORMATIVE DISPLAYS (Standard)”3”[OFF] = not active


ULTRASonic energy meter 0.6 – 2.5 m3/h<strong>Ultrasonic</strong> <strong>com</strong>pact heat meter SHARKYModel <strong>773</strong>DAtasheet ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>SIMPLE OPERATIONA pushbutton mounted on the front of the meter is used to switch to the various displays. The button can be pressed for ashort or long time. A short press of the button (< 3 seconds) switches to the next display within a loop and a long press(> 3 seconds) switches to the next display loop. The "<strong>Energy</strong>” window (sequence 1.1) in the main loop is the basic display.The meter switches automatically to power save mode if the button is not pressed for approx. 4 minutes and returns to thebasic display when the button is pressed again. The loop settings can be programmed to suit the customer’s individualrequirements using the HYDRO-SET software.


DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>DIMENSIONSNominal size qp=0.6m/h qp=1.0 / 1.5m/h qp=2.5m/h qp=3.5m/h qp=6.0m/hNominal sizeL [mm] 110 130 190 190 110 130 190 190 130 190 190 260 260 260 260 260 260 L [mm]L 1 [mm] 190 230 --- --- 190 230 --- --- 230 --- --- 380 --- --- 380 --- --- L 1 [mm]L 2 [mm] Length of intergrator 150L 2 [mm] Length of intergratB [mm] Width of integrator 100B [mm] Width of integratorR [mm] Height of intergrator 50R [mm] Height of intergratorH [mm] 78 80 80 80 78 80 80 80 80 80 80 84.5 84.5 84.5 84.5 84.5 84.5 H [mm]h [mm] 14.5 18 18 47.5 14.5 18 18 47.5 18 18 47.5 23 50 62.5 23 50 62.5 h [mm]AGZ GB DN15 G1B DN20 G1B DN20 Fl. DN20 GB DN15 G1B DN20 G1B DN20 Fl. DN20 G1B DN20 G1B DN20 Fl. DN20 G1B Fl. DN25 Fl. DN32 G1B Fl. DN25 Fl. DN32 AGZAGV R R R --- R R R --- R R --- R1 --- --- R1 --- --- AGVDiameter D [mm] --- --- --- 105 --- --- --- 105 --- --- 105 --- 114 139 --- 114 139 Diameter D [mm]Diameter d [mm] --- --- --- 14 --- --- --- 14 --- --- 14 --- 14 18 --- 14 18 Diameter d [mm]Flange dimension F [mm] --- --- --- 95 --- --- --- 95 --- --- 95 --- 100 125 --- 100 125 Flange dimension F [mm]Hole circle diameter K [mm] --- --- --- 75 --- --- --- 75 --- --- 75 --- 85 100 --- 85 100 Hole circle diameter K [mm]Flange drilling --- --- --- 4 --- --- --- 4 --- --- 4 --- 4 4 --- 4 4 Flange drillingNominal size qp=10m/hqp=15m/h qp=25m/h260 L [mm] 300 300 270 300--- L 1 [mm] 440 --- --- ---15010050L 2 [mm] Length of intergratorB [mm] Width of integratorR [mm] Height of intergrator4.5 H [mm] 90 90 95 102.52.5 h [mm] 33 69 73.5 85DN32 AGZ G2B Fl. DN40 Fl. DN50 Fl. DN65--- AGV R1 --- --- ---139 Diameter D [mm] --- 148 163 18418 Diameter d [mm] --- 18 18 18125 Flange dimension F [mm] --- 138 147 170100 Hole circle diameter K [mm] --- 110 125 1454 Flange drilling --- 4 4 8


ULTRASonic energy meter 0.6 – 2.5 m3/h<strong>Ultrasonic</strong> <strong>com</strong>pact heat meter SHARKYModel <strong>773</strong>DAtasheet ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>TECHNICAL DATA<strong>Energy</strong> meter 0,6 1,0 / 1,52,53,5 610 15 25Ambient classEN 1434 class C/ABasic featuresProtection classIP 54 (heating) / IP 68 (cooling)TypeStatic <strong>com</strong>pact energy meter according to EN 1434measuring processDisplay<strong>Ultrasonic</strong> volume measurementLCD, 7 - digitDisplay indicationUnitsMWh - kWh - GJ - Gcal - MBtuTotal values9999999 - 999999.9 - 99999.99 - 9999.999Values displayedPower - energy - flow rate - temperatureMaximum q s m 3 /h 1,2 2 / 357 12 20 30 50Nominal flow rate q p m 3 /h 0,6 1,0 / 1,5 2,5 3,5610 15 25Flow rate rangesMinimum q i l/h 6 10 / 6 1035 24 40 (1) /100 60 (1) /150 250Starting l/h 1 2,5 4 7 7 20 40 50Overload q m 3 /h 2,5 4,66,718,4 18,424 36 60Temperature range Flow sensor °C5-130 °C5-150 °CPressure loss At q p p mbar 85 36 / 75 1004412895 80 75Operating pressure Maximum PN bar 16 (25) 25 16 (25) 25 16 (25) 25 16 (25) 25 16 (25) 25 25 25 25Nominal diameter DN mm 15 20 20 FL20 15 20 20 FL20 20 20 FL20 25 FL25 FL32 25 FL25 FL32 40 FL40 FL50 FL65Overall length mm 110 130 190 110 130 190 130 190260260 300 270 300temperature sensorsTypePt 100 or Pt 500 with 2- wire leadsInputSensor current mAmeasuring cycle T sMax. temperature difference max KMin. temperature difference min KStarting temperature difference KPt100 peak < 8; rms < 0.015, Pt500 peak < 2; rms < 0.012Mains unit supply: 1 sBatterie: 16 s1<strong>773</strong>0.25Absolute temp. Measuring range °C-9.9...189.9Supply voltage Operating voltage U N3.0VDC / 3.6VDC (lithium-batterie) / 230VAC / 24VAC (mains unit)Miscellaneous Weight kg 0,76 0,85 0,96 2,75 0,76 0,85 0,96 2,75 0,85 0,96 2,75 1,5 3,5 4,8 1,5 3,5 4,8 3 6,8 7,6 9,6Flow resistance coefficient Zeta 21,3 67,5 67,5 67,5 4,3 13,6 13,6 13,6 4 4 4 2,8 2,8 7,4 2,8 2,8 7,4 3,8 4 3,5 3,4(1) : Only for horizontal installation.dimensions <strong>773</strong> with qp 15 and 25 datas in english 21.11.2007 / MP


DATASHEET ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>Meter configuration for SHARKY (model <strong>773</strong>)applicationenergy meter for heatingenergy meter for coolingenergy meter for <strong>com</strong>bined heating / coolingPlease mark your itemnominal flow0.6 m/h / 110mm thread / DN 15 / GB0.6 m/h / 130mm thread / DN 20 / G1B0.6 m/h / 190mm thread / DN 20 / G1B0.6 m/h / 190mm flange / DN 201.0 m/h / 110mm thread / DN 15 / GB1.0 m/h / 130mm thread / DN 20 / G1B1.0 m/h / 190mm thread / DN 20 / G1B1.0 m/h / 190mm flange / DN 201.5 m/h / 110mm thread / DN 15 / GB1.5 m/h / 130mm thread / DN 20 / G1B1.5 m/h / 190mm thread / DN 20 / G1B1.5 m/h / 190mm flange / DN 202.5 m/h / 130mm thread / DN 20 / G1B2.5 m/h / 190mm thread / DN 20 / G1B2.5 m/h / 190mm flange / DN 203.5 m/h / 260mm thread / DN 25 / G1B3.5 m/h / 260mm flange / DN 253.5 m/h / 260mm flange / DN 326 m/h / 260mm thread / DN 25 / G1B6 m/h / 260mm flange / DN 256 m/h / 260mm flange / DN 3210 m/h / 300mm thread / DN 40 / G2B10 m/h / 300mm flange / DN 4015 m/h / 270mm flange / DN 5025 m/h / 300mm flange / DN 65pressurePN16 (only thread)PN25installationsupply (forward)return (standard)verificationwithout type approval markwith EN approvalwith EN approval and verification (if feasible)with MID approval mark (with declaration of conformity)with MID approval mark (without declaration of conformity)cable between calculator and flow sensor0.2 m cable1.5 m cable (standard)3 m cable5 m cable (only for qp 0.6m/h up to 2.5m/h)power supplybattery 3.0V DC (C-cell) 12 year lifetime (standard)battery 3.6V DC (D-cell) 16 year lifetimemains unit 230V ACmains unit 24V ACinterface modulesmodules slot 1without module (standard)M-Bus moduleRS-232 moduleReal Data radio modulepulse input module (2 inputs)modules slot 2without module (standard)pulse output module (2 outputs)pulse input module (2 inputs)<strong>com</strong>bined module (2 inputs / 1 output)(standard setting for pulse input modules: 100l/pulse(standard setting for pulse output modules: energyand volume, pulse value is the last digit in thecorresponding display)energy unitkWh (without digit after <strong>com</strong>ma)MWh (with 3 digit after <strong>com</strong>ma)MWh (with 2 digit after <strong>com</strong>ma)GJ (with 3 digit after <strong>com</strong>ma)GJ (with 2 digit after <strong>com</strong>ma)Gcal (with 3 digit after <strong>com</strong>ma)Gcal (with 2 digit after <strong>com</strong>ma)MBtu (with 3 digit after <strong>com</strong>ma)(units with other digits after <strong>com</strong>ma on request)temperature sensors (pair)without sensorsPt 500 / direct sensor (Ø 3.3 mm)Pt 100 / 2 m cable (standard)Pt 500 / 2 m cablePt 500 / 3 m cablePt 500 / 5 m cablePt 500 / 10 m cablePt 500 / 20 m cable (just for Ø 6.0 mm with EN approval)(standard: with EN-approval)diameter temperature sensors5.2 mm (standard)6.0 mmdirect sensor (Ø 3.3 mm)temperature sensor mountingone sensor mounted in the flow part (only for direct sensoror sensors with Ø 5.2 mm) standard for sizes qp 2.5m/hindirect mounting (2 free sensors)standard for sizes qp 3.5m/hpockets (pair)withoutfor 5.2 mm temperature sensors (standard)brass-pockets, 34 mmbrass-pockets, 50 mmbrass-pockets, 70 mmbrass-pockets, 85 mmbrass-pockets, 120 mmfor 6 mm temperature sensorsbrass-pockets, 40 mmbrass-pockets, 85 mmbrass-pockets, 120 mmstainless steel-pockets, 85 mmstainless steel-pockets, 120 mmstainless steel-pockets, 155 mmstainless steel-pockets, 210 mmquantity:<strong>com</strong>pany name:contact person HYDROMETER:country approval:miscellaneous:piecesPlease <strong>com</strong>plete this configuration sheet and return it.HYDROMETER GmbH Postfach 1462, 91505 Ansbachdelivery adress: Industriestrasse 13, 91522 Ansbachwww. <strong>Hydrometer</strong>.de Tel. +49 (0)981 / 1806-0 Fax: +49 (0)981 / 1806-605 and -615meter configuration <strong>773</strong>_e new.xlsMPHB


ModuleCommunicationDesignationOrder numberM-Bus module 542 000 01Radio module 542 000 17RS-232 module 542 000 07RS 232 module incl. data cable 542 000 30data cable for RS 232 module087HY0121Functionmodule for 1 volume and 1 energy pulse output 542 000 02module for 2 additional pulse inputs 542 000 03module for 2 pulse input and 1 pulse output 542 000 26Power supplylithium battery 3,0V DC 542 000 06lithium batterie 3,6V DC (incl. regulator) 542 000 16mains unit 24V AC 542 000 05mains unit 230V AC 542 000 04ZubehÖRDAtasheet ultrasonic <strong>com</strong>pact energy metermodel <strong>773</strong>Adapter für TemperaturfühlerAdapter für Temperaturfühlereinbau❑ <strong>Hydrometer</strong> GmbH · PO. Box 1462 · 91505 Ansbach/Germany ❑ Delivery address · Industriestraße 13 · 91522 Ansbach/Germany❑ www.hydrometer.de ❑ Phone: +49 (0) 9 81/18 06 - 0 ❑ Fax: +49 (0) 9 81 / 18 06 - 66510

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!