PULSARpoint<strong>600</strong> seriesPULSARProcess MeasurementDescriptionThe <strong>Pulsar</strong>point <strong>600</strong> series is a range ofultrasonic non invasive liquid and slurrylevel switches. They provide easy toinstall reliable and non intrusive point levelindication. The <strong>Pulsar</strong>point <strong>600</strong> series isused on metal tanks containing liquids andslurries to provide indication of rising orfalling liquid levels.ApplicationThe <strong>Pulsar</strong>point <strong>600</strong> is attached to theouter wall of the tank at a point coincidingwith the level at which indication isrequired. Ultrasonic soundwaves aretransmitted through the side wall of thetank to detect the absence or presence ofthe liquid, by monitoring the characteristicsof the reflected soundwaves. A change in condition isindicated once material reaches the required level. Theoutput may be assigned to indicate a 'wet' or dry' conditionat the required level.OperationThe <strong>Pulsar</strong>point <strong>600</strong> series is non-intrusive by attaching thelevel measurement switch to the outside of the tank, thereis no need to drill or cut the tank wall and there is also nocontact with the fluid being measured. There are no movingparts and therefore no cleaning or maintenancerequirements. This highly reliable non invasive technologycan be applied to many different fluids and once installed iseasily calibrated. Among many typical applications the<strong>Pulsar</strong>point <strong>600</strong> will provide over-fill protection, leakdetection or low level liquid alarm to prevent, for instance,pump damage.<strong>Pulsar</strong>point <strong>600</strong> series operates within temperature rangesof -40˚C to + 90˚C. The <strong>600</strong> version provides an outputvia a 1 amp volt free contact changeover. The 610 & 611versions provide 4-20mA point level indication. Simple toinstall using the supplied mounting plate. The <strong>600</strong> seriescan be used in existing process control applicationswithout the need for vessel modification. The 611intrinsically safe version is available for use in flammableatmospheres.A rugged stainless steel enclosure provides a high degreeof protection from bumps, shock and vibrations within atypical industrial environment.The <strong>Pulsar</strong>point <strong>600</strong> series incorporates a uniqueself-check routine which can be initiated from time to timeand which will automatically self-check both system andinstallation integrity.Calibration is simple via a single button with two LEDstatus indicators.Calibration and set-up instructions are illustrated withinthe unit.A liquid level repeatability of ± 1mm can be achievedthrough a tank wall thickness of 2.5mm up to 40mm onmetal tanks providing there is no internal corrosionpresent.Features• Non-invasive point level detection• Relay version (<strong>600</strong>)• Two wire loop powered version (610)• Intrinsically safe version (611)• Microprocessor controlled• Auto calibrate 'wet' or 'dry'• Alarm 'wet' or 'dry'• Single button setup• Repeatability ±1mm• Unique installation self-check routine.<strong>Pulsar</strong>point 610 attached to vessel using optional self adhesive aluminium plateSpecifying information and wiring diagrams are available on request from <strong>Pulsar</strong><strong>600</strong> <strong>Series</strong>non invasive level switches<strong>Pulsar</strong> ProcessMeasurement Ltd.Oak HouseBromyard RoadWorcester WR2 5HPEngland.Telephone:+44 (0)870 6039 112Fax:+44 (0)870 6039 114e mail:info@pulsar-pm.<strong>com</strong>Web site:www.pulsar-pm.<strong>com</strong><strong>Pulsar</strong> IncPO Box 800ShalimarFlorida 32579USATelephone:+1 850 609 1777Fax:+1 850 651 4777e mail:info@pulsar-us.<strong>com</strong>Web site:www.pulsar-us.<strong>com</strong>


Technical Specification: <strong>600</strong> <strong>Series</strong>Outputs<strong>Pulsar</strong>point <strong>600</strong><strong>Pulsar</strong>point 610<strong>Pulsar</strong>point 611 (Intrinsically safe EEx ia IIC T6)Power requirementsOperating temperaturesIngress protection ratingVessel specificationsVessel diameterVessel wall thicknessVessel materialMaximum fluid viscositySize / weightHousing materialCE / EMC Approval1 volt free contact, programmable 1A, 30V dc SPCO4 to 20mA current sink (loop powered)4 to 20mA current sink (loop powered)18-36V dc-40˚C to +90˚CInstallation Re<strong>com</strong>mendationsThe <strong>Pulsar</strong>point units should be mounted in direct contact with the outside wall of the tank, which should be clean and free from anyloose or flaking material. The sensor to tank contact area should be coated with non melting waterproof silicone <strong>com</strong>pound to providea direct acoustic coupling. The supplied self adhesive aluminium plate will firmly position and clamp the sensor in place.Commissioning and set-up are simple and straight forward. The set-up consists of a one button calibration routine to enable setting theoption of wet or dry indication.IP68Greater than 250mm diameter2.5 to 40mmMetal or glass100 centipoiseSize: 118mm L x 70mm H x 65mmWeight: 1kgType 316 stainless steel investment castingComplies with BS EN 50081-1:1992 for emissions & BS EN 50082-2:1995 for immunityBump, shock & vibrationComplies with BS <strong>600</strong>68Flammable atmospheres approvalZone ‘O’ EEx ia IIC T6 (<strong>Pulsar</strong>point 611)InstallationBy means of the semi flexible self adhesion type aluminium mounting plate with fasteners ( temperature range -40˚Cto +90˚C) using a silicone grease acoustic coupler applied to the base of the sensor and the tank. Silicone <strong>com</strong>poundfrom Dow Corning DC-4 or equal.Cable entryM20 x 1.5mm for glandRepeatability & responseRepeatability± 1.0mmMinimum response time1.0 secondVariable alarm hold off1 to 255 secondsRepresented byCertificate No: 950136Our policy is one of constant development and improvement. <strong>Pulsar</strong> reserve theright to amend technical details as necessary.LP 07.05. <strong>600</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!