Dometic Service Manual - Bryant RV Services
Dometic Service Manual - Bryant RV Services
Dometic Service Manual - Bryant RV Services
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
LP GAS REQUIREMENTSThe LP gas pressure to the refrigerator should be 11 inches water column with half of all BTU’s of the<strong>RV</strong> turned on. With all other appliances off, the pressure to the refrigerator should not exceed 12 incheswater column. To check the gas pressure when the refrigerator is operating, there is a pressure test porton the solenoid.LP GAS COMPONENTSMANUAL GAS SHUTOFF VALVETo check the shutoff valve, remove andinspect for any obstructions.PowerModule.CoverAMES & AESTestFlexible CordShutoff Valve\Gas Connection OrificeROYALE & ELITESILHOUETTEPRESSURE TEST PORTTHERMOCOUPLE\MANUALGAS(Shown in“ON” position)AMES & AESSOLENOID VALVEMANUAL GAS SHUTOFF(Shown in “ON” position)PRESSURE TEST PORTORIFICE20