VENTILATIONThe coach vent system must be able to provide a way to direct the hot air, produced by the action of thecooling unit, out away from the installation of the refrigerator. In a proper installation, there should be aslittle open space as possible surrounding the sides and top of the refrigerator to achieve proper air flow.0" CLEARANCEFROM SIDE ANDCLEARANCEFROMCOMBUSTIBLEMATERIALSPATH OFAIR FLOWNOTE: Refrigerator should be installed in accordance with appropriate installation instructionsreceived with the refrigerator.AIR LEAKSCheck the gasket on the doors to be sure of a positive air seal.If a gasket is not sealing properly, first warm the gasket material with a hair drier. Close the door andthe magnetic strip should pull the gasket to themetal frame. Also check that the cooling unitis installed properly.AMES/AES MODELS:The refrigerator is secured in the enclosurewith six screws and they must be installed inthe following order:First Two Screws:Installed on the front base.Second Two Screws:Installed in the top frame.Third Two Screws:Installed in the rear base.26