A Division Of The <strong>Clark</strong>-<strong>Reliance</strong> CorporationSpecialists in Liquid Level Indication®<strong>J200</strong> <strong>Series</strong><strong>RF</strong> <strong>Capacitance</strong>Electronic Level <strong>Switch</strong>Section: JS100Bulletin: JS100.40Date: 2/1/07FEATURES• Coating Rejection Circuitry• Conductive & Non-Conductive Liquids• Explosion Proof Enclosure• Time Delay Relay• Field Selectable Hi/Lo Failsafe• Integral or Remote Mounting• FM and CSA AvailableOPERATIONThe <strong>J200</strong> <strong>Series</strong> <strong>RF</strong> <strong>Capacitance</strong> level switches are designed forpoint level alarm or control of conductive and non-conductiveliquids, granular materials, foams, pastes, slurries and interfaceapplications.The <strong>J200</strong> <strong>Series</strong> may be used with any Jerguson insulated ordriven shield level sensing probe. When a driven shield probe isused, special shield driven circuitry ignores the effect ofconductive material build-up on the level probe surface. Otherfeatures include adjustable relay time delay to preventchattering in turbulent applications and field-selectable low orhigh level fail-safe modes of operation.An optional differential adjustment feature is available forhigh/low pump control. The <strong>J200</strong> <strong>Series</strong> is also offered with aPUSH-TO-TEST option to verify high level (overflow) alarmoperation without actually filling the vessel. This easy test isperformed at the unit or from a remote location via a switchclosure. (An adjustable capacitor is switched in parallel withlevel probe to check proper sensitivity adjustment and that theinstrument functions properly.)The electronics are housed in a cast aluminum weatherproofand explosion proof enclosure. Certifications options areavailable for the <strong>J200</strong> <strong>Series</strong> by FM or CSA when used with aninsulated type level probe.The <strong>J200</strong> <strong>Series</strong> enclosures are normally mounted directly onthe level probe fitting, but can also be mounted up to 25 feetfrom the level probe using remote mount accessories.SPECIFICATIONSOperational:Measurement ............... <strong>RF</strong> <strong>Capacitance</strong>Setpoint Range ............ 0.1 to 250pFTemperature Range .....-40 to 160°F electronics;...... Wetside -40 to 450°FProtection .................... <strong>RF</strong>I, EMI, and designed to pass...... IEC-801-2 static discharge testSpark Protection .......... 100 ampsPower Requirements ... 120 or 240 VAC±10%; 50-60 Hz...... 24 VDC±4 VDC; 6 wattsRelay Function:Output ..................... Qty (1) DPDT, Two Form C contacts...... 5A Resistive @ 120/240 VAC...... 5A Resistive @ 30 VDCTime Delay.............. Adjustable 0-20 seconds, field-...... selectable to delay on pull-in,...... drop-out, or both directionsFail-Safe.................. Field Selectable Low or HighPerformance:Sensitivity.................... 0.2pFStability ....................... 0.01pF per 24 hrsTemperature Drift........ 0.01pF per °FRepeatability................ 0.1pFResponse Time ............ 100 milliseconds minimumMechanical:Enclosure..................... Cast aluminum, urethane finish...... Cl. I, Div. 1, Grp. C & DSensor Wetted Mat’ls .. 316 SST and PFA TeflonConnection .................. 3/4" NPTNet Weight................... 4.5 lbs. (2.0 kg) approximatelyJERGUSON ® GAGE AND VALVEA Division of The <strong>Clark</strong> • <strong>Reliance</strong> ® Corporation16633 Foltz Parkway • Strongsville, OH 44149 USATelephone: (440) 572-1500 • Fax: (440) 238-8828


<strong>J200</strong> <strong>Series</strong> <strong>RF</strong> <strong>Capacitance</strong> Electronic Level <strong>Switch</strong>INTEGRAL MOUNTINGREMOTE MOUNTINGCODEJRL99JRH99REMOTE ELECTRONIC OPTIONSLow temp. (160°F max.) – specify in feetHigh temp. (450°F max.) – specify in feetMODEL SELECTION GUIDECODE ELECTRONICSJ21 <strong>Capacitance</strong> <strong>Switch</strong>, 120 VAC 50/60 Hz Powered, DPDT Relay Rated 5A @ 120/240 VACJ22 <strong>Capacitance</strong> <strong>Switch</strong>, 240 VAC 50/60 Hz Powered, DPDT Relay Rated 5A @ 120/240 VACJ24 <strong>Capacitance</strong> <strong>Switch</strong>, 24 VDC Powered, 6 Watts Max, DPDT Relay Rated 5A @ 30 VDCCODE ELECTRONIC OPTIONS0 None – For use with standard electronics above1 Differential gap for high/low pump control2 Push-to-test option for Alarm VerificationCODE PROBES CONNECTION D1 D2G General Purpose 3/4" NPT 3/8" 1/4"H Heavy Duty 1" NPT 5/8" 1/2"D Driven Shield, <strong>RF</strong> Shield Driver 3/4" NPT N/A 3/8"F Flexible Cable 3/4" NPT 1/2" 3/8"CODE WETTED MATERIALS 316 Stainless Steel – NPT Connection and ProbeCODE INSULATION MATERIALN None required – For bare probe applicationsT Teflon – For most applicationsK Kynar – Increased gain for low dielectric serviceCODE PROBE LENGTH99 Specify in inches (“F” probes specify in feet)CODE MOUNTING00 Standard NPT as noted aboveJ21 O G S T 24 00 TYPICAL MODEL NUMBERJERGUSON ® GAGE AND VALVEA Division of The <strong>Clark</strong> • <strong>Reliance</strong> ® Corporation16633 Foltz Parkway • Strongsville, OH 44149 USATelephone: (440) 572-1500 • Fax: (440) 238-8828

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!