6.5 Heat Pump - Two stage with no auxiliary stage<br />
Equipment Wiring<br />
Thermostat Settings<br />
Equipment Type<br />
• TYPE: Heat Pump<br />
• # OF COOL STAGES: 2<br />
• # OF HEAT STAGES: 2<br />
• REV. VALVE:<br />
o Select whether the reversing valve is on in cool or on in heat. The default is on in<br />
cool.<br />
Equipment Settings<br />
• ALLOW HP+AUX ON:<br />
o Set to yes if the heat pump and auxiliary heat can be on at the same time fan<br />
(common with auxiliary electric heat).<br />
o Set to no if the heat pump should be off when the auxiliary heat is on (common<br />
with auxiliary fossil fuel heat).<br />
o The default is Yes.<br />