6.5 Heat Pump - Two stage with no auxiliary stage<br />

Equipment Wiring<br />

Thermostat Settings<br />

Equipment Type<br />

• TYPE: Heat Pump<br />

• # OF COOL STAGES: 2<br />

• # OF HEAT STAGES: 2<br />

• REV. VALVE:<br />

o Select whether the reversing valve is on in cool or on in heat. The default is on in<br />

cool.<br />

Equipment Settings<br />

• ALLOW HP+AUX ON:<br />

o Set to yes if the heat pump and auxiliary heat can be on at the same time fan<br />

(common with auxiliary electric heat).<br />

o Set to no if the heat pump should be off when the auxiliary heat is on (common<br />

with auxiliary fossil fuel heat).<br />

o The default is Yes.<br />