capacitor protectionintroductionCapacitor banks are used to compensate forreactive energy absorbed by electricalsystem loads, <strong>and</strong> sometimes to make upfilters to reduce harmonic voltage.Their role is to improve the quality of theelectrical system.They may be connected in star, delta <strong>and</strong>double star arrangements, depending on thelevel of voltage <strong>and</strong> the system load.A capacitor comes in the form of a case withinsulating terminals on top. It comprisesindividual capacitances which have limitedmaximum permissible voltages(e.g. 2250 V) <strong>and</strong> are series-mounted ingroups to obtain the required voltagewithst<strong>and</strong> <strong>and</strong> parallel-mounted to obtainedthe desired power rating.There are two types of capacitors:those with no internal protection,those with internal protection:a fuse is combined with each individualcapacitance.types of faultsgroupe 1groupe 2groupe 3groupe n(fig.1)Vn-1Vn-1VThe main faults which are liable to affectcapacitor banks are:overload,short-circuit,frame fault,capacitor component short-circuit.An overload is due to temporary orcontinuous overcurrent:continuous overcurrent linked to:raising of the power supply voltage,the flow of harmonic current due to thepresence of non-linear loads such as staticconverters (rectifiers, variable speed drives),arc furnaces, etc.,temporary overcurrent linked to theenergizing of a capacitor bank step.Overloads result in overheating which hasan adverse effect on dielectric withst<strong>and</strong><strong>and</strong> leads to premature capacitor aging.A short-circuit is an internal or externalfault between live conductors, phase-tophaseor phase-to-neutral depending onwhether the capacitors are delta or starconnected.The appearance of gas in thegas-tight chamber of the capacitor createsoverpressure which may lead to the openingof the case <strong>and</strong> leakage of the dielectric.A capacitor component short-circuit isdue to the flashover of an individualcapacitance.with no internal protection: the parallelwiredindividual capacitances are shuntedby the faulty unit:the capacitor impedance is modifiedthe applied voltage is distributed to oneless group in the serieseach group is submitted to greater stress,which may result in further, cascadingflashovers, up to a full short-circuit.with internal protection: the melting of therelated internal fuse eliminates the faultyindividual capacitance:the capacitor remains fault-free,its impedance is modified accordingly.A frame fault is an internal fault between alive capacitor component <strong>and</strong> the framecreated by the metal chamber.Similar to internal short-circuits, theappearance of gas in the gas-tight chamberof the capacitor creates overpressure whichmay lead to the opening of the case <strong>and</strong>leakage of the dielectric.Merlin Gerin protection guide 47

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!