12.07.2015 Views

LOKRING TOOL - MSAWorld.com

LOKRING TOOL - MSAWorld.com

LOKRING TOOL - MSAWorld.com

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Lokring Connector Size and MaterialThe tolerance fit generally built into Lokring connectors is as follows.•Lokring capillary tube connectors have a tube O.D. tolerance of plus or minus0.1 mm & <strong>com</strong>e in sizes 1.6, 1.8, 2, 2.2 and 2.5mm.•The most popular sizes for US appliances are 1.8 and 2mm.•If the O.D. measurement of the capillary tube falls between 2 sizes try thesmaller size connector 1 st . “fit doesn’t fit”. Then use the smaller connector if itfits over the tubing.•The tolerance for connector sizes 3mm thru 11 mm is plus or minus 0.2 mm•Example 7.8 to 8.2 O.D. uses a 8mm Lokring connector 8.3 to 8.7 uses a 8.5.•Lokring connectors for appliance repairs <strong>com</strong>e in <strong>com</strong>mon sizes 3mm and largerevery 0.5mm including reducer type connectors.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!