12.07.2015 Views

Electrak: underfloor to workstation system guide - Legrand

Electrak: underfloor to workstation system guide - Legrand

Electrak: underfloor to workstation system guide - Legrand

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

floor grommetsaccess / power and dataEG0010EG0030EG0040EG0045Dimensions and technical information (p. 33)PackCat. Nos. Plastic access grommetsPackCat. Nos. Plastic power and data grommetsQuick fit installationPrecision engineered from hard wearing durable ABSGrey mouldings. Other colours available <strong>to</strong> specialorderGrommets conform <strong>to</strong> IEC-61534-22Simply secured by pushing down the spring-loadedscrews and rotating a quarter turn1 EG0010 144 mm Ø – cut-out size 127 mm ØCan accomodate all cable types or three metalconduits up <strong>to</strong> a 20 mm Ø or 25 mm without foam1 EG0030 169 mm Ø – cut-out size 152 mm ØAllows power, data and flexible conduit up <strong>to</strong> 32 mm<strong>to</strong> pass through raised access floorLid can be locked with screw (included)Maximum number of conduits :9 x 20 mm Ø5 x 25 mm Ø3 x 32 mm ØNEW1 EG0055 232 mm Ø – cut-out size 215 mm ØHigh capacity grommetRecommended for installation in light traffic areasNEWAluminium access grommetBody – cast aluminiumLid – injection moulded plastic Nylon 66 withneoprene cable gasketSecured by quarter-turn fastenersFloor depth 25 <strong>to</strong> 55 mmAccess grommet depth 60 mm(95 mm when back box included)1 EG0015 144 mm Ø – cut-out size 127 mm ØAllows power, data and flexibleconduit up <strong>to</strong> 25 mm <strong>to</strong> passthrough raised access floorAluminium power grommet1 EG0025 13 A power grommetSupplied complete with 13 Aunswitched socketNEWNEW169 mm Ø – cut-out size 152 mm ØQuick fit installationPrecision engineered from hard wearing durable ABSGrey mouldings. Other colours available <strong>to</strong> specialorder. Conform <strong>to</strong> IEC-61534-22Removable carpet recessCable flap feature so grommet lid can be closedwhile in useSimply secured by pushing down the spring loadedscrews and rotating a quarter turn1 EG0040 13 A power grommetSupplied complete with13 A unswitched socket1 EG0045 RCD power grommetSupplied complete with 13 A RCD socket1 EG0051 13 A power/data grommetSupplied complete with 13 A socket and1 x 37 x 22 mm cut-out1 EG0052 Data grommetSupplied complete with data plate2 x 37 x 22 mm cut-outNEWPre-wired power grommets169 mm Ø – cut-out size 152 mm ØCleaners socket version1 EG0041 DP1332 - 3 m unfused1 EG0042 DP1532 - 5 m unfused1 EG0043 DP1313 - 3 m 13 A fused1 EG0044 DP1513 - 5 m 13 A fusedRCD socket version1 EG0046 DP1332 - 3 m unfused1 EG0047 DP1532 - 5 m unfused1 EG0048 DP1313 - 3 m 13 A fused1 EG0049 DP1513 - 5 m 13 A fused32

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!